Literature DB >> 27232902

Optical Assessment of Soft Contact Lens Edge-Thickness.

Patrice Tankam1, Jungeun Won, Cristina Canavesi, Ian Cox, Jannick P Rolland.   

Abstract

PURPOSE: To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2-μm imaging resolution in three dimensions and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses.
METHODS: A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester, NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error.
RESULTS: The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. Fifty cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 μm.
CONCLUSIONS: The results confirmed the ability of GD-OCM to provide high-definition images of soft contact lens edges. As a nondestructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCM in the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance.

Entities:  

Mesh:

Year:  2016        PMID: 27232902      PMCID: PMC4961562          DOI: 10.1097/OPX.0000000000000892

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  30 in total

1.  Comparative study of the three neurofilament subunits within pig and human retinal ganglion cells.

Authors:  Javier Ruiz-Ederra; Monica García; David Hicks; Elena Vecino
Journal:  Mol Vis       Date:  2004-02-10       Impact factor: 2.367

2.  Vision specific quality of life of pediatric contact lens wearers.

Authors:  Marjorie J Rah; Jeffrey J Walline; Lisa A Jones-Jordan; Loraine T Sinnott; John Mark Jackson; Ruth E Manny; Bradley Coffey; Stacy Lyons
Journal:  Optom Vis Sci       Date:  2010-08       Impact factor: 1.973

3.  Broadband astigmatism-corrected Czerny-Turner spectrometer.

Authors:  Kye-Sung Lee; Kevin P Thompson; Jannick P Rolland
Journal:  Opt Express       Date:  2010-10-25       Impact factor: 3.894

4.  Dispersion control with a Fourier-domain optical delay line in a fiber-optic imaging interferometer.

Authors:  Kye-Sung Lee; A Ceyhun Akcay; Tony Delemos; Eric Clarkson; Jannick P Rolland
Journal:  Appl Opt       Date:  2005-07-01       Impact factor: 1.980

5.  The TFOS International Workshop on Contact Lens Discomfort: report of the contact lens interactions with the tear film subcommittee.

Authors:  Jennifer P Craig; Mark D P Willcox; Pablo Argüeso; Cecile Maissa; Ulrike Stahl; Alan Tomlinson; Jianhua Wang; Norihiko Yokoi; Fiona Stapleton
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-10-18       Impact factor: 4.799

6.  The TFOS International Workshop on Contact Lens Discomfort: report of the contact lens interactions with the ocular surface and adnexa subcommittee.

Authors:  Nathan Efron; Lyndon Jones; Anthony J Bron; Erich Knop; Reiko Arita; Stefano Barabino; Alison M McDermott; Edoardo Villani; Mark D P Willcox; Maria Markoulli
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-10-18       Impact factor: 4.799

7.  Application of optical coherence tomography to automated contact lens metrology.

Authors:  Bryan R Davidson; Jennifer K Barton
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

8.  Parallelized multi-graphics processing unit framework for high-speed Gabor-domain optical coherence microscopy.

Authors:  Patrice Tankam; Anand P Santhanam; Kye-Sung Lee; Jungeun Won; Cristina Canavesi; Jannick P Rolland
Journal:  J Biomed Opt       Date:  2014-07       Impact factor: 3.170

9.  Characterization of soft contact lens edge fitting using ultra-high resolution and ultra-long scan depth optical coherence tomography.

Authors:  Meixiao Shen; Lele Cui; Colleen Riley; Michael R Wang; Jianhua Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-09       Impact factor: 4.799

10.  Entire contact lens imaged in vivo and in vitro with spectral domain optical coherence tomography.

Authors:  Meixiao Shen; Michael R Wang; Jianhua Wang; Yimin Yuan; Feng Chen
Journal:  Eye Contact Lens       Date:  2010-03       Impact factor: 2.018

View more
  4 in total

1.  Development of ciprofloxacin-loaded contact lenses using fluorous chemistry.

Authors:  Guoting Qin; Zhiling Zhu; Siheng Li; Alison M McDermott; Chengzhi Cai
Journal:  Biomaterials       Date:  2017-01-31       Impact factor: 12.479

2.  Longitudinal optical coherence tomography to visualize the in vivo response of middle ear biofilms to antibiotic therapy.

Authors:  Jungeun Won; Wenzhou Hong; Pawjai Khampang; Darold R Spillman; Samuels Marshall; Ke Yan; Ryan G Porter; Michael A Novak; Joseph E Kerschner; Stephen A Boppart
Journal:  Sci Rep       Date:  2021-03-04       Impact factor: 4.379

3.  Inverted lens provides reverse geometry solution for post laser vision correction (LVC) corneas.

Authors:  Nir Erdinest; Naomi London; Itay Lavy; Nadav Levinger
Journal:  Am J Ophthalmol Case Rep       Date:  2022-01-26

4.  Ten Years of Gabor-Domain Optical Coherence Microscopy.

Authors:  Cristina Canavesi; Jannick P Rolland
Journal:  Appl Sci (Basel)       Date:  2019-06-24       Impact factor: 2.679

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.