Literature DB >> 20210455

Application of optical coherence tomography to automated contact lens metrology.

Bryan R Davidson1, Jennifer K Barton.   

Abstract

Optical coherence tomography (OCT) is a nondestructive imaging modality with the potential to make quantitative spatial measurements. OCT's noncontact nature, sensitivity to small refractive index mismatches, and micron-scale resolution make it attractive for contact lens metrology, specifically, measuring prism. Prism is defined as the maximum difference in thickness of the contact lens, measured over a full 360 deg of rotation, at a fixed distance from the contact lens edge. We develop and test a novel algorithm that automatically analyzes OCT images and calculates prism. Images are obtained using a Thorlabs OCT930SR OCT system. The OCT probe is fastened to an automated rotation stage that rotates 360 deg in small increments (typically 10 deg) to acquire OCT images of the edge of the contact lens around the entire circumference. The images are 1.6 mm in optical depth (512 pixels) and 2 mm wide (1000 pixels). Several sets of images are successfully analyzed. The prism measured for a toric lens is 42 microm, which is in line with design parameters. Thickness measurements are repeatable with a standard deviation of 0.5 microm and maximum range of 1.8 microm over ten image sets. This work demonstrates the possibility of using OCT to perform nondestructive contact lens metrology.

Mesh:

Year:  2010        PMID: 20210455     DOI: 10.1117/1.3292598

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  4 in total

1.  Extended scan depth optical coherence tomography for evaluating ocular surface shape.

Authors:  Meixiao Shen; Lele Cui; Ming Li; Dexi Zhu; Michael R Wang; Jianhua Wang
Journal:  J Biomed Opt       Date:  2011-05       Impact factor: 3.170

2.  Accurate tissue interface segmentation via adversarial pre-segmentation of anterior segment OCT images.

Authors:  Jiahong Ouyang; Tejas Sudharshan Mathai; Kira Lathrop; John Galeotti
Journal:  Biomed Opt Express       Date:  2019-09-20       Impact factor: 3.732

3.  Optical Assessment of Soft Contact Lens Edge-Thickness.

Authors:  Patrice Tankam; Jungeun Won; Cristina Canavesi; Ian Cox; Jannick P Rolland
Journal:  Optom Vis Sci       Date:  2016-08       Impact factor: 1.973

4.  Clinical translation of handheld optical coherence tomography: practical considerations and recent advancements.

Authors:  Guillermo L Monroy; Jungeun Won; Darold R Spillman; Roshan Dsouza; Stephen A Boppart
Journal:  J Biomed Opt       Date:  2017-12       Impact factor: 3.170

  4 in total