Literature DB >> 24695868

Parallelized multi-graphics processing unit framework for high-speed Gabor-domain optical coherence microscopy.

Patrice Tankam1, Anand P Santhanam2, Kye-Sung Lee3, Jungeun Won4, Cristina Canavesi5, Jannick P Rolland6.   

Abstract

Gabor-domain optical coherence microscopy (GD-OCM) is a volumetric high-resolution technique capable of acquiring three-dimensional (3-D) skin images with histological resolution. Real-time image processing is needed to enable GD-OCM imaging in a clinical setting. We present a parallelized and scalable multi-graphics processing unit (GPU) computing framework for real-time GD-OCM image processing. A parallelized control mechanism was developed to individually assign computation tasks to each of the GPUs. For each GPU, the optimal number of amplitude-scans (A-scans) to be processed in parallel was selected to maximize GPU memory usage and core throughput. We investigated five computing architectures for computational speed-up in processing 1000×1000 A-scans. The proposed parallelized multi-GPU computing framework enables processing at a computational speed faster than the GD-OCM image acquisition, thereby facilitating high-speed GD-OCM imaging in a clinical setting. Using two parallelized GPUs, the image processing of a 1×1×0.6  mm3 skin sample was performed in about 13 s, and the performance was benchmarked at 6.5 s with four GPUs. This work thus demonstrates that 3-D GD-OCM data may be displayed in real-time to the examiner using parallelized GPU processing.

Mesh:

Year:  2014        PMID: 24695868      PMCID: PMC4019421          DOI: 10.1117/1.JBO.19.7.071410

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  50 in total

1.  A GPU-based framework for modeling real-time 3D lung tumor conformal dosimetry with subject-specific lung tumor motion.

Authors:  Yugang Min; Anand Santhanam; Harini Neelakkantan; Bari H Ruddy; Sanford L Meeks; Patrick A Kupelian
Journal:  Phys Med Biol       Date:  2010-08-16       Impact factor: 3.609

2.  Broadband astigmatism-corrected Czerny-Turner spectrometer.

Authors:  Kye-Sung Lee; Kevin P Thompson; Jannick P Rolland
Journal:  Opt Express       Date:  2010-10-25       Impact factor: 3.894

3.  Dispersion control with a Fourier-domain optical delay line in a fiber-optic imaging interferometer.

Authors:  Kye-Sung Lee; A Ceyhun Akcay; Tony Delemos; Eric Clarkson; Jannick P Rolland
Journal:  Appl Opt       Date:  2005-07-01       Impact factor: 1.980

4.  Cellular resolution optical coherence microscopy with high acquisition speed for in-vivo human skin volumetric imaging.

Authors:  Kye-Sung Lee; Kevin P Thompson; Panomsak Meemon; Jannick P Rolland
Journal:  Opt Lett       Date:  2011-06-15       Impact factor: 3.776

5.  Real-time three-dimensional Fourier-domain optical coherence tomography video image guided microsurgeries.

Authors:  Jin U Kang; Yong Huang; Kang Zhang; Zuhaib Ibrahim; Jaepyeong Cha; W P Andrew Lee; Gerald Brandacher; Peter L Gehlbach
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

6.  Four-dimensional structural and Doppler optical coherence tomography imaging on graphics processing units.

Authors:  Marcin Sylwestrzak; Daniel Szlag; Maciej Szkulmowski; Iwona Gorczynska; Danuta Bukowska; Maciej Wojtkowski; Piotr Targowski
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

7.  Graphics processing unit accelerated optical coherence tomography processing at megahertz axial scan rate and high resolution video rate volumetric rendering.

Authors:  Yifan Jian; Kevin Wong; Marinko V Sarunic
Journal:  J Biomed Opt       Date:  2013-02       Impact factor: 3.170

8.  Full-range k-domain linearization in spectral-domain optical coherence tomography.

Authors:  Mansik Jeon; Jeehyun Kim; Unsang Jung; Changho Lee; Woonggyu Jung; Stephen A Boppart
Journal:  Appl Opt       Date:  2011-03-10       Impact factor: 1.980

Review 9.  OCT imaging of skin cancer and other dermatological diseases.

Authors:  Mette Mogensen; Lars Thrane; Thomas M Jørgensen; Peter E Andersen; Gregor B E Jemec
Journal:  J Biophotonics       Date:  2009-07       Impact factor: 3.207

10.  Real-time 3D and 4D Fourier domain Doppler optical coherence tomography based on dual graphics processing units.

Authors:  Yong Huang; Xuan Liu; Jin U Kang
Journal:  Biomed Opt Express       Date:  2012-08-20       Impact factor: 3.732

View more
  6 in total

1.  Measurement of a multi-layered tear film phantom using optical coherence tomography and statistical decision theory.

Authors:  Jinxin Huang; Qun Yuan; Buyun Zhang; Ke Xu; Patrice Tankam; Eric Clarkson; Matthew A Kupinski; Holly B Hindman; James V Aquavella; Thomas J Suleski; Jannick P Rolland
Journal:  Biomed Opt Express       Date:  2014-11-24       Impact factor: 3.732

2.  Optical Assessment of Soft Contact Lens Edge-Thickness.

Authors:  Patrice Tankam; Jungeun Won; Cristina Canavesi; Ian Cox; Jannick P Rolland
Journal:  Optom Vis Sci       Date:  2016-08       Impact factor: 1.973

3.  Assessing microstructures of the cornea with Gabor-domain optical coherence microscopy: pathway for corneal physiology and diseases.

Authors:  Patrice Tankam; Zhiguo He; Ying-Ju Chu; Jungeun Won; Cristina Canavesi; Thierry Lepine; Holly B Hindman; David J Topham; Philippe Gain; Gilles Thuret; Jannick P Rolland
Journal:  Opt Lett       Date:  2015-03-15       Impact factor: 3.776

4.  Capabilities of Gabor-domain optical coherence microscopy for the assessment of corneal disease.

Authors:  Patrice Tankam; Zhiguo He; Gilles Thuret; Holly B Hindman; Cristina Canavesi; Johana Coyoc Escudero; Thierry Lépine; Philippe Gain; Jannick P Rolland
Journal:  J Biomed Opt       Date:  2019-04       Impact factor: 3.170

5.  Quantitative assessment of human donor corneal endothelium with Gabor domain optical coherence microscopy.

Authors:  Changsik Yoon; Amanda Mietus; Yue Qi; Jonathon Stone; Johana Escudero; Cristina Canavesi; Patrice Tankam; Holly Hindman; Jannick Rolland
Journal:  J Biomed Opt       Date:  2019-08       Impact factor: 3.170

6.  Ten Years of Gabor-Domain Optical Coherence Microscopy.

Authors:  Cristina Canavesi; Jannick P Rolland
Journal:  Appl Sci (Basel)       Date:  2019-06-24       Impact factor: 2.679

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.