Literature DB >> 2723275

Left heart opacification with peripheral venous injection of a new saccharide echo contrast agent in dogs.

M D Smith1, J L Elion, R R McClure, O L Kwan, A N DeMaria.   

Abstract

Opacification of the left heart chambers after venous injection of echo contrast agents with transpulmonary capabilities has been difficult to achieve because of a lack of availability of a biodegradable nontoxic agent that produces uniformly small microbubbles. SHU-508 is a new saccharide echo contrast agent that produces bubble sizes from 2 to 8 microns in diameter, capable of traversing the pulmonary capillary bed and resulting in left heart contrast. The echo intensity produced by this agent was compared with that of agitated saline solution, indocyanine green and SHU-454 (another experimental saccharide agent for right-sided contrast) during 136 injections in eight dogs. Videotaped two-dimensional echographic images were digitized and analyzed with the use of videodensitometry for peak right and left ventricular intensity, pulmonary transit times and time of persistence of contrast. The highest right ventricular intensity value (3,594 +/- 1,393) was achieved with SHU-508 (p less than 0.05 compared with the other agents). The right ventricular contrast seen with SHU-508 also persisted for a longer period (22.8 +/- 12 s) than with the standard agents (p less than 0.001). Left ventricular contrast with SHU-508 was visually evident in all 42 injections, whereas the peak left ventricular intensity was 35% as bright as that produced in the right ventricle by the same agent. Peak left ventricular intensity values from SHU-508 were compared with those from agitated saline solution injected from the pulmonary capillary wedge position in four dogs. SHU-508 produced brighter left ventricular intensity (1,281 +/- 607) compared with that obtained with the saline-wedge technique (p les than 0.002).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2723275     DOI: 10.1016/0735-1097(89)90357-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  14 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  Left ventricular opacification after peripheral venous injection of a modified albumin solution.

Authors:  S L Lin; J H Lo; C Y Mou; S J Ho; R H Liu; J Y Chan; M S Chang; H T Chiang; C Y Chen
Journal:  Int J Card Imaging       Date:  1992

6.  Comparison of a new intravenous echo contrast agent (BY 963) with Albunex for opacification of left ventricular cavity.

Authors:  R Leischik; K D Beller; R Erbel
Journal:  Basic Res Cardiol       Date:  1996 Jan-Feb       Impact factor: 17.165

Review 7.  Contrast echocardiography for assessment of myocardial perfusion.

Authors:  R Leischik; J Rose; G Caspari; A Skyschally; G Heusch; R Erbel
Journal:  Herz       Date:  1997-02       Impact factor: 1.443

Review 8.  Advances in molecular imaging with ultrasound.

Authors:  Ryan Gessner; Paul A Dayton
Journal:  Mol Imaging       Date:  2010-06       Impact factor: 4.488

9.  Feasibility and Diagnostic Potential of Pulmonary Transit Time Measurement by Contrast Echocardiography: A Pilot Study.

Authors:  Evan L Brittain; Laura N Doss; Linda Saliba; Waleed Irani; Benjamin F Byrd; Ken Monahan
Journal:  Echocardiography       Date:  2015-02-13       Impact factor: 1.724

10.  Flow quantitation by radio frequency analysis of contrast echocardiography.

Authors:  D Rovai; M Lombardi; A Mazzarisi; L Landini; L Taddei; A Distante; A Benassi; A L'Abbate
Journal:  Int J Card Imaging       Date:  1993-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.