Literature DB >> 27219727

Total Knee Post-Cam Design Variations and Their Effects on Kinematics and Wear Patterns.

William M Mihalko, Julie Lowell, Genymphas Higgs, Steven Kurtz.   

Abstract

Post-cam designs for posterior-stabilized total knee arthroplasy (TKA) implants have evolved over the last 2 decades. These designs have evolved from symmetric post and cam to asymmetric designs that include anterior post interactions to affect a kinematic change in full extension. All design changes have consequences on the resulting femorotibial contact kinematics and, depending on the amount of constraint built into the design, these changes may have significant consequences on the wear patterns on the tibial polyethylene insert. The current authors review the kinematic effects of symmetric and asymmetric cam designs and use a retrieval database of TKA implants obtained at the time of necropsy to show how different design variables may affect polyethylene wear patterns after 10 or more years of implantation or from modeled wear in simulators. More modern designs seem to have moved the post posteriorly and sloped the anterior aspect to avoid impingement of the anterior post in terminal flexion on the inferior aspect of the patella button. [Orthopedics. 2016; 39(3):S45-S49.]. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27219727     DOI: 10.3928/01477447-20160509-14

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

1.  Different intraoperative kinematics, stability, and range of motion between cruciate-substituting ultracongruent and posterior-stabilized total knee arthroplasty.

Authors:  Hagen Fritzsche; Franziska Beyer; Anne Postler; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-01-16       Impact factor: 4.342

2.  Impact of femoro-tibial size combinations and TKA design on kinematics.

Authors:  Ingrid Dupraz; Christoph Thorwächter; Thomas M Grupp; Florian Hammerschmid; Matthias Woiczinski; Volkmar Jansson; Peter E Müller; Arnd Steinbrück
Journal:  Arch Orthop Trauma Surg       Date:  2021-05-22       Impact factor: 3.067

3.  Biomechanical Characteristics of Three Baseplate Rotational Arrangement Techniques in Total Knee Arthroplasty.

Authors:  KwanSu Kang; Young Woong Jang; Oui Sik Yoo; Dukyoung Jung; Sung-Jae Lee; Myung Chul Lee; Dohyung Lim
Journal:  Biomed Res Int       Date:  2018-06-06       Impact factor: 3.411

4.  Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report.

Authors:  Abdulaziz Alkheraiji; Sultana Borai; Rheema Alfadhil; Fawzi AlJassir
Journal:  Int J Surg Case Rep       Date:  2022-07-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.