Literature DB >> 27218479

Reliability of the Knee Smartphone-Application Goniometer in the Acute Orthopedic Setting.

Luís Carlos Pereira1, Sylvia Rwakabayiza1, Estelle Lécureux2, Brigitte M Jolles1.   

Abstract

The standard goniometer (SG) is the most commonly used tool to assess range of motion (ROM) in patients with knee restrictions. Several medical applications have been designed to measure joint ROM. Little data are available on their reliability in the postoperative clinical setting. The purpose of this study was to assess whether a smartphone accelerometer-based knee goniometer application (App) is as reliable as the SG to measure knee ROM in clinical settings. A total of 60 subjects were included in this cross-sectional reliability trial. Overall, 20 healthy subjects (HS) and 20 acute postoperative patients (PO) underwent three active and three passive measurements in knee flexion and extension, using the SG and the smartphone knee goniometer App. To determine the fatigability of postoperative patients, a third group of 20 patients underwent a single active measurement in knee flexion and extension (PO1). Measurements were performed by three clinicians. For intraobserver reliability, mean intraclass correlation coefficient (ICC) values were higher for the App in all circumstances (overall mean SG 0.85, App 0.91), indicating an excellent correlation. For interobserver reliability, the highest ICC scores were in the PO1 group, with the App more consistent than the SG in all movements. Interobserver reliability was lower in the PO group versus PO1. Interobserver reliability was better for active ROM than for passive measurements. The overall concordance coefficient was very good to excellent with active measurements (range, 0.60-0.97). In conclusion, the App is a reliable tool for use in acute orthopedic care and offers better intra- and interobserver correlation scores for a single active measurement. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2016        PMID: 27218479     DOI: 10.1055/s-0036-1584184

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  8 in total

1.  Validity and reliability of smartphone inclinometer applications for measurement of elbow range of motion in paediatric patients.

Authors:  Denis P Koong; Jillian Lee; Tegan L Cheng; David G Little
Journal:  J Child Orthop       Date:  2020-10-01       Impact factor: 1.548

2.  Evaluation of benefits and accuracy of a mobile application in planning total knee arthroplasties.

Authors:  João Bosco Sales Nogueira; Abrahão Cavalcante Gomes de Souza Carvalho; Edgar Marçal de Barros Filho; Leonardo Heráclio do Carmo Araújo; Marcelo José Cortez Bezerra; Marco Kawamura Demange
Journal:  Rev Bras Ortop       Date:  2018-02-27

3.  Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: A systematic review.

Authors:  Justin W L Keogh; Alistair Cox; Sarah Anderson; Bernard Liew; Alicia Olsen; Ben Schram; James Furness
Journal:  PLoS One       Date:  2019-05-08       Impact factor: 3.240

4.  A Recurrent Synovial Osteochondromatosis of the Knee: A Case Report.

Authors:  Sripur Manandhar; Jiazhen Li; Xin-Chang Lu; Yan Zhang; Yi Zhang; Yongkui Liu; Chao Zhang
Journal:  Int Med Case Rep J       Date:  2021-02-10

5.  Accuracy and reliability of a smartphone application for measuring the knee joint angle.

Authors:  Keisuke Ishii; Hiroyuki Oka; Yuji Honda; Daisuke Oguro; Youichiro Konno; Kousuke Kumeta; Shouta Nishihara; Hazuki Matsuyama; Ichiro Kaneko; Yasuo Takeuchi; Yoshinobu Watanabe; Hirotaka Kawano; Naoshi Ogata
Journal:  J Phys Ther Sci       Date:  2021-05-15

Review 6.  The Use of mHealth in Orthopedic Surgery: A Scoping Review.

Authors:  Sara Dionisi; Noemi Giannetta; Emanuele Di Simone; Francesco Ricciardi; Gloria Liquori; Aurora De Leo; Lorenzo Moretti; Christian Napoli; Marco Di Muzio; Giovanni Battista Orsi
Journal:  Int J Environ Res Public Health       Date:  2021-11-28       Impact factor: 3.390

7.  Comparison of a Smartphone App to Manual Knee Range of Motion Measurements.

Authors:  Paul W Knapp; Robert A Keller; Kathryn A Mabee; Jing Shi; Raji Pillai; Nicholas B Frisch
Journal:  Arthroplast Today       Date:  2022-04-04

8.  Accuracy and reliability of knee goniometry methods.

Authors:  Graeme Ethan Hancock; Tracey Hepworth; Kevin Wembridge
Journal:  J Exp Orthop       Date:  2018-10-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.