Literature DB >> 2721255

Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand.

K Reinhart1, T Rudolph, D L Bredle, L Hannemann, S M Cain.   

Abstract

Because central venous O2 saturation (superior vena cava, ScvO2) can be monitored with less patient risk than mixed venous O2 saturation (pulmonary artery, SvO2), we examined the correlations between SvO2 and ScvO2 over a broad range of cardiorespiratory conditions, including hypoxia, hemorrhage, and resuscitation in anesthetized dogs. The correlation coefficient (r) between SvO2 and ScvO2 in 179 simultaneously drawn blood samples from 22 dogs was 0.97. In another nine dogs, the two sites were continuously and simultaneously monitored with fiberoptic catheters; r was 0.96 with a mean difference of 3.7 +/- 2.9 percent (SD) saturation. In each dog the changes in ScvO2 closely paralleled the changes in SvO2. Although absolute values of ScvO2 are not sufficiently identical to SvO2 to calculate O2 uptake or pulmonary shunt precisely, close tracking of changes in the two sites across a wide range of hemodynamic conditions warrant further consideration of ScvO2 for patient monitoring of trends in O2 supply/demand.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2721255     DOI: 10.1378/chest.95.6.1216

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  45 in total

Review 1.  Emerging therapies in severe sepsis.

Authors:  S J Finney; T W Evans
Journal:  Thorax       Date:  2002-10       Impact factor: 9.139

2.  Does central venous oxygen saturation accurately reflect mixed venous oxygen saturation? Nothing is simple, unfortunately.

Authors:  J L Vincent
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

3.  Using physiological models and decision theory for selecting appropriate ventilator settings.

Authors:  S E Rees; C Allerød; D Murley; Y Zhao; B W Smith; S Kjaergaard; P Thorgaard; S Andreassen
Journal:  J Clin Monit Comput       Date:  2006-09-15       Impact factor: 2.502

Review 4.  Venous oximetry.

Authors:  Frank Bloos; Konrad Reinhart
Journal:  Intensive Care Med       Date:  2005-06-04       Impact factor: 17.440

5.  Methods of monitoring shock.

Authors:  Ednan K Bajwa; Atul Malhotra; B Taylor Thompson
Journal:  Semin Respir Crit Care Med       Date:  2004-12       Impact factor: 3.119

6.  Neutropenic patient with fever and abdominal pain.

Authors:  Hallie Metz; Carrie Tibbles
Journal:  Intern Emerg Med       Date:  2008-03       Impact factor: 3.397

Review 7.  Clinical evidence of blood transfusion effectiveness.

Authors:  Andreas Pape; Peter Stein; Oliver Horn; Oliver Habler
Journal:  Blood Transfus       Date:  2009-10       Impact factor: 3.443

8.  Accuracy of continuous central venous oxygen saturation monitoring in patients undergoing cardiac surgery.

Authors:  Werner Baulig; Alexander Dullenkopf; Andreas Kobler; Barbara Baulig; Hans Rudolf Roth; Edith R Schmid
Journal:  J Clin Monit Comput       Date:  2008-04-29       Impact factor: 2.502

9.  Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock.

Authors:  Hugo Mozina; Matej Podbregar
Journal:  Crit Care       Date:  2010-03-23       Impact factor: 9.097

10.  Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill.

Authors:  Konrad Reinhart; Hans-Jörg Kuhn; Christiane Hartog; Donald L Bredle
Journal:  Intensive Care Med       Date:  2004-06-09       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.