Literature DB >> 2720982

Correction of instrument- and reagent-based differences in determination of the International Normalized Ratio (INR) for monitoring anticoagulant therapy.

J L van Rijn1, N A Schmidt, W P Rutten.   

Abstract

As recommended by the World Health Organization, standardization of prothrombin time assays involves conversion of prothrombin times into International Normalized Ratios (INR). We investigated the effect of two different methods (Nycomed's Thrombotest, and Instrumentation Laboratory's PT-fibrinogen) and three coagulation instruments (Schnitger & Gross, KC-10, and ACL) on calculations of INR. The INR plots showed considerable scatter of individual values around the regression lines when the two different methods were compared. Systematic differences in the outcome of INR calculation were related to the use of the different coagulation instruments. Prothrombin times obtained with the different instruments were linearly correlated. We used the bias of these lines to correct results for both the patients' samples and the reference samples. This correction yielded INR values from the different instruments that agreed well.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2720982

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  6 in total

Review 1.  Oral anticoagulant therapy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Walter Ageno; Alexander S Gallus; Ann Wittkowsky; Mark Crowther; Elaine M Hylek; Gualtiero Palareti
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

2.  Screening INR deviation of local prothrombin time systems.

Authors:  L Poller
Journal:  J Clin Pathol       Date:  1998-05       Impact factor: 3.411

3.  Multicentre evaluation of the Thrombotest International Sensitivity Index used with a steel ball coagulometer.

Authors:  A M van den Besselaar; R H Peters
Journal:  J Clin Pathol       Date:  1996-05       Impact factor: 3.411

4.  A New Generation Prothrombin Time Method for INR.

Authors:  Juha Horsti; Helena Uppa; Juhani A Vilpo
Journal:  Open Med Chem J       Date:  2008-02-27

5.  Point-of-care and standard laboratory coagulation testing during cardiovascular surgery: balancing reliability and timeliness.

Authors:  J C Fitch; G P Mirto; K L Geary; D W Byrne; R L Hines
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

6.  Evaluation of the Steelex M600H coagulometer prothrombin time-international normalized ratio assay with Steelex test reagents.

Authors:  Yasemin U Budak; Kağan Huysal; Murat Polat; Gülsevil Tarakçi; Hakan Uçar
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.