Literature DB >> 27162726

Evaluation of the Ex-PRESS(®) P-50 implant under scleral flap in combined cataract and glaucoma surgery.

Valentín Huerva1, Jordi Soldevila1, Francisco J Ascaso2, Laura Lavilla2, M Jesús Muniesa1, M Carmen Sánchez1.   

Abstract

AIM: To evaluate the efficacy and safety of glaucoma drainage device Ex-PRESS(®) P-50 for combined cataract surgery and glaucoma.
METHODS: Patients having cataract and open angle glaucoma or patients with open advanced glaucoma which needed two or more antiglaucoma medications were included. Combined cataract surgery and glaucoma with Ex-PRESS(®) P-50 model placed under scleral flap was performed.
RESULTS: Out of 40 eyes of 40 patients (55% male and 45% female) completed the study during one-year follow-up. The mean of age was 76.6±11.02y. The intraocular pressure (IOP) decreased significantly during the 12-month follow-up from 23.5 mm Hg to 16.8 mm Hg (Wilcoxon signed ranks test, P<0.001). A 59.5% of patients did not need any topical treatment, 10.8% of them needed one active principle, 27% needed two active principles, and 2.7% of them needed three active principles for successful IOP control (<21 mm Hg).
CONCLUSION: Combined surgery of phacoemulsification with ExPRESS(®) P-50 lowers IOP from the preoperative baseline and reduces significantly the number of antiglaucoma active principles for IOP control after the operation.

Entities:  

Keywords:  Ex-PRESS; cataract surgery; combined surgery; glaucoma surgery

Year:  2016        PMID: 27162726      PMCID: PMC4853349          DOI: 10.18240/ijo.2016.04.11

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  22 in total

1.  Long-term follow-up of initially successful trabeculectomy.

Authors:  T C Chen; J T Wilensky; M A Viana
Journal:  Ophthalmology       Date:  1997-07       Impact factor: 12.079

2.  Spontaneous extrusion of a stainless steel glaucoma drainage implant (Ex-PRESS).

Authors:  M Tavolato; S Babighian; A Galan
Journal:  Eur J Ophthalmol       Date:  2006 Sep-Oct       Impact factor: 2.597

3.  Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap.

Authors:  Peter J G Maris; Kyoko Ishida; Peter A Netland
Journal:  J Glaucoma       Date:  2007-01       Impact factor: 2.503

4.  Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery.

Authors:  Elliott M Kanner; Peter A Netland; Steven R Sarkisian; Haiming Du
Journal:  J Glaucoma       Date:  2009-08       Impact factor: 2.503

5.  Randomized, prospective, comparative trial of EX-PRESS glaucoma filtration device versus trabeculectomy (XVT study).

Authors:  Peter A Netland; Steven R Sarkisian; Marlene R Moster; Iqbal Ike K Ahmed; Garry Condon; Sarwat Salim; Mark B Sherwood; Carla J Siegfried
Journal:  Am J Ophthalmol       Date:  2013-11-07       Impact factor: 5.258

6.  Trabeculectomy. Preliminary report of a new method.

Authors:  J E Cairns
Journal:  Am J Ophthalmol       Date:  1968-10       Impact factor: 5.258

7.  Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification.

Authors:  C E Traverso; F De Feo; A Messas-Kaplan; P Denis; S Levartovsky; E Sellem; F Badalà; Z Zagorski; A Bron; S Gandolfi; M Belkin
Journal:  Br J Ophthalmol       Date:  2005-04       Impact factor: 4.638

8.  Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study.

Authors:  Sonja Wamsley; Marlene R Moster; Sushma Rai; Heryberto S Alvim; Joann Fontanarosa
Journal:  Am J Ophthalmol       Date:  2004-12       Impact factor: 5.258

Review 9.  [Combined glaucoma cataract surgeries].

Authors:  S Milazzo; J Touboul; D Brémond-Gignac; E Hachet
Journal:  J Fr Ophtalmol       Date:  2012-08-22       Impact factor: 0.818

10.  The first report on intermediate-term outcome of Ex-PRESS glaucoma filtration device implanted under scleral flap in Japanese patients.

Authors:  Tetsuya Sugiyama; Maho Shibata; Shota Kojima; Mari Ueki; Tsunehiko Ikeda
Journal:  Clin Ophthalmol       Date:  2011-07-29
View more
  1 in total

1.  Evaluation of EX-PRESS glaucoma implant in elderly diabetic patients after 23G vitrectomy.

Authors:  Anita Lyssek-Boroń; Adam Wylęgała; Dariusz Dobrowolski; Ewelina Kowalczyk; Katarzyna Polanowska; Edward Wylęgała
Journal:  Clin Interv Aging       Date:  2017-04-10       Impact factor: 4.458

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.