Literature DB >> 27162084

Quantification of residual dose estimation error on log file-based patient dose calculation.

Yoshiyuki Katsuta1, Noriyuki Kadoya2, Yukio Fujita3, Eiji Shimizu4, Kenichi Matsunaga4, Haruo Matsushita5, Kazuhiro Majima4, Keiichi Jingu5.   

Abstract

PURPOSE: The log file-based patient dose estimation includes a residual dose estimation error caused by leaf miscalibration, which cannot be reflected on the estimated dose. The purpose of this study is to determine this residual dose estimation error. METHODS AND MATERIALS: Modified log files for seven head-and-neck and prostate volumetric modulated arc therapy (VMAT) plans simulating leaf miscalibration were generated by shifting both leaf banks (systematic leaf gap errors: ±2.0, ±1.0, and ±0.5mm in opposite directions and systematic leaf shifts: ±1.0mm in the same direction) using MATLAB-based (MathWorks, Natick, MA) in-house software. The generated modified and non-modified log files were imported back into the treatment planning system and recalculated. Subsequently, the generalized equivalent uniform dose (gEUD) was quantified for the definition of the planning target volume (PTV) and organs at risks.
RESULTS: For MLC leaves calibrated within ±0.5mm, the quantified residual dose estimation errors that obtained from the slope of the linear regression of gEUD changes between non- and modified log file doses per leaf gap are in head-and-neck plans 1.32±0.27% and 0.82±0.17Gy for PTV and spinal cord, respectively, and in prostate plans 1.22±0.36%, 0.95±0.14Gy, and 0.45±0.08Gy for PTV, rectum, and bladder, respectively.
CONCLUSIONS: In this work, we determine the residual dose estimation errors for VMAT delivery using the log file-based patient dose calculation according to the MLC calibration accuracy.
Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  DVH; Log file; Patient QA; Radiotherapy; VMAT

Mesh:

Year:  2016        PMID: 27162084     DOI: 10.1016/j.ejmp.2016.04.015

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  9 in total

1.  Monitoring of mechanical errors and their dosimetric impact throughout the course of non-coplanar continuous volumetric-modulated arc therapy.

Authors:  Hideaki Hirashima; Mitsuhiro Nakamura; Yuki Miyabe; Megumi Uto; Kiyonao Nakamura; Takashi Mizowaki
Journal:  Radiat Oncol       Date:  2018-02-14       Impact factor: 3.481

2.  Trajectory log analysis and cone-beam CT-based daily dose calculation to investigate the dosimetric accuracy of intensity-modulated radiotherapy for gynecologic cancer.

Authors:  Yohei Utena; Jun Takatsu; Satoru Sugimoto; Keisuke Sasai
Journal:  J Appl Clin Med Phys       Date:  2021-01-10       Impact factor: 2.102

3.  Assessment of log-based fingerprinting system of Mobius3D with Elekta linear accelerators.

Authors:  Yu-Yun Noh; Jihun Kim; Jin Sung Kim; Han-Back Shin; Min Cheol Han; Tae Suk Suh
Journal:  J Appl Clin Med Phys       Date:  2021-11-27       Impact factor: 2.102

4.  Insensitivity of machine log files to MLC leaf backlash and effect of MLC backlash on clinical dynamic MLC motion: An experimental investigation.

Authors:  Michael Barnes; Dennis Pomare; Marcus Doebrich; Therese S Standen; Joshua Wolf; Peter Greer; John Simpson
Journal:  J Appl Clin Med Phys       Date:  2022-06-09       Impact factor: 2.243

5.  Development of a Monte Carlo based robustness calculation and evaluation tool.

Authors:  Hannes A Loebner; Werner Volken; Silvan Mueller; Jenny Bertholet; Paul-Henry Mackeprang; Gian Guyer; Daniel M Aebersold; Marco F M Stampanoni; Peter Manser; Michael K Fix
Journal:  Med Phys       Date:  2022-05-04       Impact factor: 4.506

6.  Evaluation of 4-Hz log files and secondary Monte Carlo dose calculation as patient-specific quality assurance for VMAT prostate plans.

Authors:  Philipp Szeverinski; Matthias Kowatsch; Thomas Künzler; Marco Meinschad; Patrick Clemens; Alexander F DeVries
Journal:  J Appl Clin Med Phys       Date:  2021-06-20       Impact factor: 2.102

7.  Patient-Specific Quality Assurance Using Monte Carlo Dose Calculation and Elekta Log Files for Prostate Volumetric-Modulated Arc Therapy.

Authors:  Yoshiyuki Katsuta; Noriyuki Kadoya; Yukio Fujita; Eiji Shimizu; Kenichi Matsunaga; Kinya Sawada; Haruo Matsushita; Kazuhiro Majima; Keiichi Jingu
Journal:  Technol Cancer Res Treat       Date:  2017-12-05

8.  Quality assurance of geometric accuracy based on an electronic portal imaging device and log data analysis for Dynamic WaveArc irradiation.

Authors:  Hideaki Hirashima; Yuki Miyabe; Mitsuhiro Nakamura; Nobutaka Mukumoto; Takashi Mizowaki; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2018-04-06       Impact factor: 2.102

9.  Practical implications for the quality assurance of modulated radiation therapy techniques using point detector arrays.

Authors:  Steffi Kantz; Almut Troeller McDermott; Matthias Söhn; Sabine Reinhardt; Claus Belka; Katia Parodi; Michael Reiner
Journal:  J Appl Clin Med Phys       Date:  2017-08-30       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.