Literature DB >> 27156201

A randomized comparison of novel bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with acute coronary syndromes: The CENTURY II high risk ACS substudy.

Victor A Jiménez1, Andrés Iñiguez2, José A Baz2, Mariano Valdés3, Alberto Ortiz2, André Vuilliomenet4, Vicente Mainar5, Dariusz Dudek6, Shmuel Banai7, David Tüller8, Jean-Louis Bonnet9, Antonio De Miguel2, Guillermo Bastos2, William Wijns10, Shigeru Saito11.   

Abstract

BACKGROUND: To investigate clinical outcomes of percutaneous coronary intervention using a sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES) compared with a permanent polymer everolimus-eluting stent, Xience (PP-EES) in patients with high risk (ST-segment elevation and non-ST-segment elevation myocardial infarction) acute coronary syndromes (ACS) enrolled in the CENTURY II trial.
METHODS: CENTURY II is a prospective, multicenter, randomized, single blind, controlled trial comparing BP-SES and PP-EES, with primary endpoint of target lesion failure (TLF) at 9month post-stent implantation. Out of 1123 patients enrolled in CENTURY II trial, 264 high risk ACS patients were included in this subgroup analysis, and the clinical outcomes including target lesion failure (TLF), target vessel failure (TVF), cardiac death, myocardial infarction, and stent thrombosis were evaluated at 24months.
RESULTS: The baseline clinical, angiographic and procedural characteristics were similar between two groups. At 24months, TLF occurred in 6.3% of patients receiving a BP-SES and 6.5% of patients receiving a PP-EES (P=0.95); TVF was 6.3% in patients receiving a BP-SES and 9.4% in patients receiving a PP-EES (P=0.36). There were no significant differences in cardiac death, myocardial infarction and stent thrombosis rate.
CONCLUSIONS: BP-SES achieved similar safety and efficacy outcomes as PP-EES in this ACS subgroup of CENTURY II study, at 24-month follow-up. This finding is hypothesis-generating and needs to be confirmed in larger trials with longer follow-up.
Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Acute coronary syndrome; bioresorbable polymer; drug-eluting stent

Mesh:

Substances:

Year:  2016        PMID: 27156201     DOI: 10.1016/j.carrev.2016.04.001

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  5 in total

Review 1.  Evolutionary perspective of drug eluting stents: from thick polymer to polymer free approach.

Authors:  Sadia Hassan; Murtaza Najabat Ali; Bakhtawar Ghafoor
Journal:  J Cardiothorac Surg       Date:  2022-04-04       Impact factor: 1.637

Review 2.  The Ultimaster Biodegradable-Polymer Sirolimus-Eluting Stent: An Updated Review of Clinical Evidence.

Authors:  Alberto Chisari; Anna Maria Pistritto; Raffaele Piccolo; Alessio La Manna; Gian Battista Danzi
Journal:  Int J Mol Sci       Date:  2016-09-06       Impact factor: 5.923

Review 3.  Adverse cardiovascular events associated with biodegradable polymer drug-eluting stents and durable polymer everolimus-eluting stents: A systematic review and meta-analysis of 10 randomized controlled trials.

Authors:  Pravesh Kumar Bundhun; Girish Janoo; Chandra Mouli Yanamala; Feng Huang
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

4.  Biodegradable Polymer DES (Ultimaster) vs. Magnesium Bioresorbable Scaffold (BRS Magmaris) in Diabetic Population with NSTE-ACS: A One-Year Clinical Outcome of Two Sirolimus-Eluting Stents.

Authors:  Piotr Rola; Adrian Włodarczak; Mateusz Barycki; Marek Szudrowicz; Magdalena Łanocha; Jan Jakub Kulczycki; Karol Turkiewicz; Katarzyna Woźnica; Maciej Lesiak; Adrian Doroszko
Journal:  J Diabetes Res       Date:  2021-11-23       Impact factor: 4.011

5.  Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction.

Authors:  Paweł Gąsior; Marek Gierlotka; Krzysztof Szczurek-Katanski; Marcin Osuch; Magda Roleder; Michal Hawranek; Mariusz Gasior; Wojciech Wojakowski; Lech Polonski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2018-11-09       Impact factor: 1.426

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.