Five-year experience with the adjustable transobturator male system for the treatment of male stress urinary incontinence: a single-center evaluation.

Sandra Mühlstädt1, Alexander Friedl2, Nasreldin Mohammed3, André Schumann3, Karl Weigand3, Felix Kawan3, Christian Göllert3, Christin Kahlert3, Gerit Theil3, Kersten Fischer3, Paolo Fornara3.   

Abstract

BACKGROUND: We report on our 5-year experience with the adjustable transobturator male system (ATOMS®, A.M.I., Feldkirch, Austria).
METHODS: Between 10-2009 and 10-2014, 54 patients received an ATOMS. The mean follow-up of this retrospective observational trial was 27.5 ± 18.4 (2.3-59) months. Within each follow-up, the following were evaluated: micturition protocol, 24-h pad count, uroflowmetry and residual volume. Statistical analysis was performed with SigmaPlot® 11.0, p < 0.05 considered as significant.
RESULTS: Stress urinary incontinence (SUI) I°, II° and III° was seen in 1 (1.9 %), 16 (29.6 %) and 37 patients (68.5 %), respectively. In summary, 48.1 % of the patients became "dry" (0-"safty pad"/day), while 29.6 % achieved at least an "improvement" of about more than 50 % (1-2 pads/day), which corresponds to an overall success rate of 77.7 %. The mean number of pads/day decreased from 7.7 to 1.6. Regarding the initial degree of SUI, patients with mild or moderate incontinence had a significantly better outcome (p = 0.002, 95 % CI 0.9066 to 2.760). Postoperative complications were scaled according to the Clavien classification, in which we have seen 4 grade I-, 1 grade IIIa- and 9 grade IIIb-complications (overall 25.9 %). The evaluation of quality of life by ICIQ-SF showed a significant improvement (p = 0.0001, 95 % CI -14.56 to -11.75).
CONCLUSION: The treatment of male SUI using the ATOMS incontinence system achieved the best results in patients with mild and moderate incontinence. For severe incontinent patients, the system represents an efficient alternative.

Entities:  

Keywords:  ATOMS; Adjustability; Artificial implants; Male stress urinary incontinence; Sphincter cushions

Mesh:

Year:  2016        PMID: 27156092     DOI: 10.1007/s00345-016-1839-x

Source DB:  PubMed          Journal:  World J Urol        ISSN: 0724-4983            Impact factor:   4.226


  21 in total

1.  Long-term functional outcomes after artificial urinary sphincter implantation in men with stress urinary incontinence.

Authors:  Priscilla Léon; Emmanuel Chartier-Kastler; Morgan Rouprêt; Vanina Ambrogi; Pierre Mozer; Véronique Phé
Journal:  BJU Int       Date:  2014-10-23       Impact factor: 5.588

2.  Initial experience and results with a new adjustable transobturator male system for the treatment of stress urinary incontinence.

Authors:  Jürgen Seweryn; Wilhelm Bauer; Anton Ponholzer; Paul Schramek
Journal:  J Urol       Date:  2012-01-20       Impact factor: 7.450

3.  Examining the validity of pressure ulcer risk assessment scales: developing and using illustrated patient simulations to collect the data.

Authors:  D Gould; D Kelly; L Goldstone; J Gammon
Journal:  J Clin Nurs       Date:  2001-09       Impact factor: 3.036

Review 4.  Systematic review and meta-analysis of studies reporting urinary continence recovery after robot-assisted radical prostatectomy.

Authors:  Vincenzo Ficarra; Giacomo Novara; Raymond C Rosen; Walter Artibani; Peter R Carroll; Anthony Costello; Mani Menon; Francesco Montorsi; Vipul R Patel; Jens-Uwe Stolzenburg; Henk Van der Poel; Timothy G Wilson; Filiberto Zattoni; Alexandre Mottrie
Journal:  Eur Urol       Date:  2012-06-01       Impact factor: 20.096

5.  A transobturator adjustable system for male incontinence: 30-month follow-up of a multicenter study.

Authors:  Salomon Victor Romano; Wilhelm Huebner; Flavio Trigo Rocha; Fernando Pires Vaz; Valter Muller; Fabio Nakamura
Journal:  Int Braz J Urol       Date:  2014 Nov-Dec       Impact factor: 1.541

Review 6.  The artificial urinary sphincter after a quarter of a century: a critical systematic review of its use in male non-neurogenic incontinence.

Authors:  Frank Van der Aa; Marcus J Drake; George R Kasyan; Andreas Petrolekas; Jean-Nicolas Cornu
Journal:  Eur Urol       Date:  2012-11-23       Impact factor: 20.096

7.  AdVance/AdVance XP transobturator male slings: preoperative degree of incontinence as predictor of surgical outcome.

Authors:  Argimiro Collado Serra; Luís Resel Folkersma; José L Domínguez-Escrig; Alvaro Gómez-Ferrer; José Rubio-Briones; Eduardo Solsona Narbón
Journal:  Urology       Date:  2013-03-07       Impact factor: 2.649

8.  A prospective study evaluating the efficacy of the artificial sphincter AMS 800 for the treatment of postradical prostatectomy urinary incontinence and the correlation between preoperative urodynamic and surgical outcomes.

Authors:  Flavio Trigo Rocha; Cristiano Mendes Gomes; Anuar Ibrahim Mitre; Sami Arap; Miguel Srougi
Journal:  Urology       Date:  2008-01       Impact factor: 2.649

Review 9.  Epidemiology of male urinary incontinence.

Authors:  Kari A O Tikkinen; Arnav Agarwal; Tomas L Griebling
Journal:  Curr Opin Urol       Date:  2013-11       Impact factor: 2.309

10.  First experience with the ATOMS(®) implant, a new treatment option for male urinary incontinence.

Authors:  Sonia Pérez González; Jose Ramón Cansino; María Alejandra Portilla; Simón Claudio Rodriguez; Luis Hidalgo; Javier De la Peña
Journal:  Cent European J Urol       Date:  2014-12-05
View more
  8 in total

1.  Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and male Readjustment Mechanical External (REMEEX) system for post-prostatectomy incontinence.

Authors:  Javier C Angulo; Sonia Ruiz; Martín Lozano; Ignacio Arance; Miguel Virseda; David Lora
Journal:  World J Urol       Date:  2020-06-11       Impact factor: 4.226

2.  Application of En Bloc and Urethral Mucosal Flap Sparing Techniques Improve the Functional Outcomes in Holmium Laser Enucleation of Prostate: A Retrospective Case Control Study.

Authors:  Jizhi Zhou; Zengrong Hua; Min Tang; Xiaoxin Meng; Pu Li
Journal:  Am J Mens Health       Date:  2022 Sep-Oct

3.  Patient satisfaction with adjustable transobturator male system in the Iberian multicenter study.

Authors:  Javier C Angulo; Ignacio Arance; Antonio Ojea; Manuel Carballo; Andrés Rodríguez; Javier Pereira; Miguel Rebassa; Antoine Teyrouz; Gregorio Escribano; Fernando Teba; Blanca Madurga; Francisco E Martins; Francisco Cruz
Journal:  World J Urol       Date:  2019-01-16       Impact factor: 4.226

4.  Implant of ATOMS® system for the treatment of postoperative male stress urinary incontinence: results of a single centre.

Authors:  Alessandro Giammò; Enrico Ammirati; Annarita Tullio; Gianni Bodo; Alberto Manassero; Paolo Gontero; Roberto Carone
Journal:  Int Braz J Urol       Date:  2019 Jan-Feb       Impact factor: 1.541

5.  Effectiveness of Adjustable Transobturator Male System (ATOMS) to Treat Male Stress Incontinence: A Systematic Review and Meta-Analysis.

Authors:  Cristina Esquinas; Javier C Angulo
Journal:  Adv Ther       Date:  2018-12-17       Impact factor: 3.845

Review 6.  Adjustable sling for the treatment of post-prostatectomy urinary incontinence: systematic review and meta-analysis.

Authors:  Laercio Antonio da Silva; Rogério Simonetti; Edina Mariko Koga da Silva
Journal:  Einstein (Sao Paulo)       Date:  2019-09-23

7.  Holmium laser enucleation of prostate by using en-bloc and bladder neck preservation technique: technical consideration and influence on functional outcomes.

Authors:  Pu Li; Chengming Wang; Min Tang; Peng Han; Xiaoxin Meng
Journal:  Transl Androl Urol       Date:  2021-01

8.  Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence.

Authors:  Javier C Angulo; Sandra Schönburg; Alessandro Giammò; Francisco J Abellán; Ignacio Arance; David Lora
Journal:  PLoS One       Date:  2019-12-02       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.