Literature DB >> 27143744

Placement of iliosacral screws using 3D image-guided (O-Arm) technology and Stealth Navigation: comparison with traditional fluoroscopy.

A A Theologis1, S Burch1, M Pekmezci1.   

Abstract

AIMS: We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy.
MATERIALS AND METHODS: Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers.
RESULTS: There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (sd) 1922) than during fluoroscopy (11.9 mRem sd 14.8) (p < 0.01).
CONCLUSION: O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. TAKE HOME MESSAGE: Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696-702. ©2016 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Accuracy; Iliosacral screw; Navigation; O-Arm; Radiation exposure; Sacral fracture

Mesh:

Year:  2016        PMID: 27143744     DOI: 10.1302/0301-620X.98B5.36287

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  11 in total

1.  Head-mounted display augmented reality to guide pedicle screw placement utilizing computed tomography.

Authors:  Jacob T Gibby; Samuel A Swenson; Steve Cvetko; Raj Rao; Ramin Javan
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-06-22       Impact factor: 2.924

2.  Accuracy of screw fixation using the O-arm® and StealthStation® navigation system for unstable pelvic ring fractures.

Authors:  Jun Takeba; Kensuke Umakoshi; Satoshi Kikuchi; Hironori Matsumoto; Suguru Annen; Naoki Moriyama; Yuki Nakabayashi; Norio Sato; Mayuki Aibiki
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-11-09

3.  Intra-operative multi-dimensional fluoroscopy of guidepin placement prior to iliosacral screw fixation for posterior pelvic ring injuries and sacroiliac dislocation: an early case series.

Authors:  James C Shaw; Milton L Chip Routt; Joshua L Gary
Journal:  Int Orthop       Date:  2017-03-29       Impact factor: 3.075

4.  Interactive Flying Frustums (IFFs): spatially aware surgical data visualization.

Authors:  Javad Fotouhi; Mathias Unberath; Tianyu Song; Wenhao Gu; Alex Johnson; Greg Osgood; Mehran Armand; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-03-12       Impact factor: 2.924

Review 5.  Computer-Assisted Surgical Navigation for Primary and Metastatic Bone Malignancy of the Pelvis: Current Evidence and Future Directions.

Authors:  Alexander B Christ; Derek G Hansen; John H Healey; Nicola Fabbri
Journal:  HSS J       Date:  2021-07-07

6.  Accuracy of navigated and conventional iliosacral screw placement in B- and C-type pelvic ring fractures.

Authors:  Josephine Berger-Groch; Marie Lueers; Johannes Maria Rueger; Wolfgang Lehmann; Darius Thiesen; Jan Philipp Kolb; Maximilian Johannes Hartel; Lars Gerhard Grossterlinden
Journal:  Eur J Trauma Emerg Surg       Date:  2018-07-20       Impact factor: 3.693

7.  Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate.

Authors:  Lin Jin; Jialiang Guo; Junfei Guo; Yingchao Yin; Zhiyong Hou; Yingze Zhang
Journal:  Biomed Res Int       Date:  2016-11-15       Impact factor: 3.411

8.  A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study.

Authors:  Fan Yang; Sheng Yao; Kai-Fang Chen; Feng-Zhao Zhu; Ze-Kang Xiong; Yan-Hui Ji; Ting-Fang Sun; Xiao-Dong Guo
Journal:  BMC Musculoskelet Disord       Date:  2018-11-13       Impact factor: 2.362

9.  Minimally Invasive Screw Fixation of Unstable Pelvic Fractures Using the "Blunt End" Kirschner Wire Technique Assisted by 3D Printed External Template.

Authors:  Kaifang Chen; Sheng Yao; Fan Yang; Deepak Drepaul; Dionne Telemacque; Fengzhao Zhu; Lian Zeng; Zekang Xiong; Tingfang Sun; Xiaodong Guo
Journal:  Biomed Res Int       Date:  2019-10-24       Impact factor: 3.411

10.  Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study.

Authors:  Pol Maria Rommens; Eva Mareike Nolte; Johannes Hopf; Daniel Wagner; Alexander Hofmann; Martin Hessmann
Journal:  Eur J Trauma Emerg Surg       Date:  2020-04-15       Impact factor: 3.693

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.