Literature DB >> 27135090

Impact of low mesopic contrast sensitivity outcomes in different types of modern multifocal intraocular lenses.

Ana B Plaza-Puche1, Jorge L Alio1,2, Esperanza Sala1, Peter Mojzis3.   

Abstract

PURPOSE: To investigate the low mesopic contrast sensitivity function (LMCSF) of patients implanted with different modern optical bifocal and trifocal designs of multifocal intraocular lenses (mfIOLs).
METHODS: This prospective, comparative, nonrandomized consecutive case series included 180 eyes that underwent cataract surgery. Six groups of eyes were differentiated: group A, eyes with the diffractive AT LISA tri 839MP; group B, eyes with diffractive FineVision; group C, eyes with the bifocal Lentis Mplus-LS313; group D, eyes with the diffractive bifocal Acri.Lisa 366D; group E, eyes with the diffractive apodized Acrysof ReSTOR SN6AD1; group F, as the control group, implanted with a monofocal spherical intraocular lens. The LMCSF was evaluated with the OPTEC® 6500 device at 3 months postoperatively using a luminance of 3 cd/m2.
RESULTS: No significant differences among groups were detected in LMCSF for the spatial frequencies of 1.5, 3.0, 6.0, and 12.0 cpd (1.5 cpd: F = 1.81, p = 0.13; 3.0 cpd: F = 1.14, p = 0.14; 6.0 cpd: F = 1.87, p = 0.11; 12.0 cpd: F = 1.26, p = 0.29), but significant differences were found among groups for the spatial frequency of 18 cpd (F = 2.62, p = 0.03). When comparing the groups in pairs, only statistically significant differences were observed between groups E and F for the spatial frequency of 18.0 cpd (t = 3.27, p = 0.03) with better values for group F.
CONCLUSION: No significant differences were observed in LMCSF among the different mfIOLs studied. The third focus of trifocal IOL models did not adversely affect the LMCSF. The ReSTOR SN6AD1 showed the poorest LMCSF for the highest spatial frequency analyzed when compared with the control group.

Entities:  

Mesh:

Year:  2016        PMID: 27135090     DOI: 10.5301/ejo.5000777

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  15 in total

1.  Comparison of visual outcomes with implantation of trifocal versus bifocal intraocular lens after phacoemulsification: a Meta-analysis.

Authors:  Juan-Juan Yang; Qiu-Ping Liu; Jing-Ming Li; Li Qin
Journal:  Int J Ophthalmol       Date:  2018-03-18       Impact factor: 1.779

2.  Trifocal diffractive intraocular lens implantation in patients after previous corneal refractive laser surgery for myopia.

Authors:  Qiu-Mei Li; Feng Wang; Zhe-Ming Wu; Zhen Liu; Chuan Zhan; Bing-Heng Chen; Jing Sima; Knut Stieger; Shao-Wei Li
Journal:  BMC Ophthalmol       Date:  2020-07-17       Impact factor: 2.209

3.  Comparison between bilateral implantation of a trifocal intraocular lens (Alcon Acrysof IQ® PanOptix) and extended depth of focus lens (Tecnis® Symfony® ZXR00 lens).

Authors:  Mohsen Farvardin; Mohammadkarim Johari; Adel Attarzade; Feisal Rahat; Reza Farvardin; Zahra Farvardin
Journal:  Int Ophthalmol       Date:  2020-10-10       Impact factor: 2.031

4.  Visual performance, reading ability and patient satisfaction after implantation of a diffractive trifocal intraocular lens.

Authors:  Rita Mencucci; Eleonora Favuzza; Orsola Caporossi; Stanislao Rizzo
Journal:  Clin Ophthalmol       Date:  2017-11-13

Review 5.  Clinical comparison of patient outcomes following implantation of trifocal or bifocal intraocular lenses: a systematic review and meta-analysis.

Authors:  Zeren Shen; Yuchen Lin; Yanan Zhu; Xin Liu; Jie Yan; Ke Yao
Journal:  Sci Rep       Date:  2017-03-28       Impact factor: 4.379

6.  Trifocal intraocular lenses: a comparison of the visual performance and quality of vision provided by two different lens designs.

Authors:  Kjell G Gundersen; Rick Potvin
Journal:  Clin Ophthalmol       Date:  2017-06-08

7.  Comparison of clinical performance between trifocal and bifocal intraocular lenses: A meta-analysis.

Authors:  Zequan Xu; Danmin Cao; Xu Chen; Song Wu; Xin Wang; Qiang Wu
Journal:  PLoS One       Date:  2017-10-26       Impact factor: 3.240

8.  Comparison of the clinical efficacy of AcrySof® IQ and TECNIS® toric intraocular lenses: A real-world study.

Authors:  Juan-Juan Yang; Ya-Zhou Qin; Li Qin; Jing-Ming Li
Journal:  Exp Ther Med       Date:  2020-08-28       Impact factor: 2.447

9.  Trifocal versus Bifocal Diffractive Intraocular Lens Implantation after Cataract Surgery or Refractive Lens Exchange: a Meta-analysis.

Authors:  Chang Ho Yoon; In-Soo Shin; Mee Kum Kim
Journal:  J Korean Med Sci       Date:  2018-09-27       Impact factor: 2.153

Review 10.  Comparison of the Clinical Performance of Refractive Rotationally Asymmetric Multifocal IOLs with Other Types of IOLs: A Meta-Analysis.

Authors:  Zequan Xu; Wenzhe Li; Lianqun Wu; Shuang Xue; Xu Chen; Qiang Wu
Journal:  J Ophthalmol       Date:  2018-09-27       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.