Literature DB >> 29600184

Comparison of visual outcomes with implantation of trifocal versus bifocal intraocular lens after phacoemulsification: a Meta-analysis.

Juan-Juan Yang1, Qiu-Ping Liu2, Jing-Ming Li1, Li Qin1.   

Abstract

AIM: To compare a trifocal intraocular lens (IOL) and a bifocal IOL implantation in improving visual function after cataract surgery.
METHODS: Eligible literatures were systematically searched through EMBASE and PubMed databases. The inclusion criteria were prospective comparative clinical trials on cataract surgery comparing trifocal IOL with bifocal IOL implantation that assessed visual acuity, contrast sensitivity and subjective vision quality. The effects were computed as standardized mean differences and pooled using fixed-effect or random-effect models.
RESULTS: Four prospective randomized controlled trials (RCTs) and five cohorts provided data were included by a systematic review, comprising 265 eyes implanted with trifocal IOLs and 264 eyes implanted with bifocal IOLs. Monocular distance visual acuity (VA) showed a statistically significant but small difference that favored trifocal IOLs (MD=-0.06; 95%CI, -0.10 to -0.02; Z=2.90, P=0.004 for uncorrected distance VA, and MD= -0.02; 95%CI, -0.03 to -0.00; Z=2.02, P=0.04 for corrected distance VA), but the data did not suggest that the effect of trifocal IOL implantation would clinically outperform bifocal IOL implantation. There was no significant difference in monocular near VA (MD=-0.01; 95%CI, -0.07 to 0.04; Z=0.42, P=0.68 for distance-corrected near VA, and MD=-0.01; 95%CI, -0.06 to 0.03; Z=0.55, P=0.58 for corrected near VA) or refraction between two groups. Contrast sensitivity and subjective visual quality had no conclusive results.
CONCLUSION: All results indicate that trifocal IOL and bifocal IOL had similar levels of monocular distance and near VA.

Entities:  

Keywords:  Meta-analysis; bifocal intraocular lens; trifocal intraocular lens; visual function

Year:  2018        PMID: 29600184      PMCID: PMC5861240          DOI: 10.18240/ijo.2018.03.20

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  15 in total

1.  Comparative analysis of the visual performance after cataract surgery with implantation of a bifocal or trifocal diffractive IOL.

Authors:  Peter Mojzis; Lucia Kukuckova; Katarina Majerova; Katerina Liehneova; David P Piñero
Journal:  J Refract Surg       Date:  2014-10       Impact factor: 3.573

2.  Comparison of a trifocal intraocular lens with a +3.0 D bifocal IOL: results of a prospective randomized clinical trial.

Authors:  Soraya M R Jonker; Noël J C Bauer; Natalia Y Makhotkina; Tos T J M Berendschot; Frank J H M van den Biggelaar; Rudy M M A Nuijts
Journal:  J Cataract Refract Surg       Date:  2015-08       Impact factor: 3.351

3.  Comparison Between Mix-and-Match Implantation of Bifocal Intraocular Lenses and Bilateral Implantation of Trifocal Intraocular Lenses.

Authors:  Rafael Bilbao-Calabuig; Felix González-López; Ferrer Amparo; Gemma Alvarez; Sunni R Patel; Fernando Llovet-Osuna
Journal:  J Refract Surg       Date:  2016-10-01       Impact factor: 3.573

4.  Visual function and higher order aberration after implantation of aspheric and spherical multifocal intraocular lenses: a meta-analysis.

Authors:  Jian-Ping Liu; Fan Zhang; Jiang-Yue Zhao; Li-Wei Ma; Jin-Song Zhang
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

5.  Quality-of-life and visual function after manual small incision cataract Surgery in South Western Nigeria.

Authors:  O Olawoye; A Ashaye; C Bekibele; A J Ajuwon
Journal:  West Afr J Med       Date:  2012 Apr-Jun

6.  Prospective Clinical Comparison of Patient Outcomes Following Implantation of Trifocal or Bifocal Intraocular Lenses.

Authors:  Béatrice Cochener
Journal:  J Refract Surg       Date:  2016-03       Impact factor: 3.573

7.  Visual performance after the implantation of a new trifocal intraocular lens.

Authors:  Jérôme C Vryghem; Steven Heireman
Journal:  Clin Ophthalmol       Date:  2013-10-01

8.  Contrast sensitivity and spherical aberration in eyes implanted with AcrySof IQ and AcrySof Natural intraocular lens: the results of a meta-analysis.

Authors:  Jianping Liu; Jiangyue Zhao; Liwei Ma; Guangcong Liu; Di Wu; Jinsong Zhang
Journal:  PLoS One       Date:  2013-10-18       Impact factor: 3.240

9.  Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses.

Authors:  Kjell Gunnar Gundersen; Rick Potvin
Journal:  Clin Ophthalmol       Date:  2016-05-10

10.  Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens.

Authors:  Kjell Gunnar Gundersen; Rick Potvin
Journal:  Clin Ophthalmol       Date:  2016-03-17
View more
  4 in total

1.  Visual Outcomes and Optical Quality of Accommodative, Multifocal, Extended Depth-of-Focus, and Monofocal Intraocular Lenses in Presbyopia-Correcting Cataract Surgery: A Systematic Review and Bayesian Network Meta-analysis.

Authors:  Jeong-Yeon Cho; Yeo Kyoung Won; Jongyeop Park; Jin Hyun Nam; Ji-Yoon Hong; Serim Min; Nahyun Kim; Tae-Young Chung; Eui-Kyung Lee; Sun-Hong Kwon; Dong Hui Lim
Journal:  JAMA Ophthalmol       Date:  2022-09-22       Impact factor: 8.253

2.  Trifocal intraocular lenses versus bifocal intraocular lenses after cataract extraction among participants with presbyopia.

Authors:  Diego Zamora-de La Cruz; Karla Zúñiga-Posselt; John Bartlett; Mario Gutierrez; Samuel A Abariga
Journal:  Cochrane Database Syst Rev       Date:  2020-06-18

3.  Bilateral trifocal IOL implantation in a pediatric case of cataract following steroid-therapy for acute lymphoblastic leukemia.

Authors:  Timur M Yildirim; Gerd U Auffarth; Hyeck-Soo Son; Christian Huber; Flemming Beisse; Ramin Khoramnia
Journal:  Am J Ophthalmol Case Rep       Date:  2018-11-20

4.  Comparison of the clinical efficacy of AcrySof® IQ and TECNIS® toric intraocular lenses: A real-world study.

Authors:  Juan-Juan Yang; Ya-Zhou Qin; Li Qin; Jing-Ming Li
Journal:  Exp Ther Med       Date:  2020-08-28       Impact factor: 2.447

  4 in total