OBJECTIVE: Previous studies reported that the location of the center of rotation (COR) at instrumented level after cervical total disc replacement (TDR) deviated from its preoperative location. However, currently, it is unknown whether the deviated COR is linked to the range of motion (ROM) at instrumented level. The purpose of this study was to evaluate the clinical outcomes after cervical TDR with ProDisc-C (Synthes, West Chester, PA, USA), as well as investigate the location change of COR at instrumented level and its clinical significance.
METHODS: A total of 23 patients who underwent single-level cervical TDR with ProDisc-C were included. Japanese Orthopaedic Association (JOA) score and Neck Disability Index (NDI) were used to assess clinical outcomes. Radiographic parameters such as cervical ROM, instrumented segmental ROM, adjacent segmental ROM, and intervertebral height were analyzed. Additionally, the location change of COR at instrumented level and its clinical significance were further analyzed by the alteration of its coordinates (COR-X, COR-Y).
RESULTS: JOA scores increased significantly, while NDI scores decreased at final follow-up. No differences were found in cervical global ROM, instrumented segmental ROM, adjacent segmental ROM, and COR-Y at instrumented level between preoperative and final follow-up measurements (p>0.05); however, intervertebral height and COR-X increased significantly (p<0.05).
CONCLUSION: Cervical global ROM, instrumented segmental ROM, and adjacent segmental ROM could be effectively maintained, and intervertebral height was increased after TDR with ProDisc-C. The location of COR at instrumented level shifted forward after cervical TDR.

Entities:  

Mesh:

Year:  2016        PMID: 27130391     DOI: 10.3944/AOTT.2016.15.0182

Source DB:  PubMed          Journal:  Acta Orthop Traumatol Turc        ISSN: 1017-995X            Impact factor:   1.511


  3 in total

1.  Single-level cervical arthroplasty with ProDisc-C artificial disc: 10-year follow-up results in one centre.

Authors:  Yanbin Zhao; Feifei Zhou; Yu Sun; Shengfa Pan
Journal:  Eur Spine J       Date:  2019-09-05       Impact factor: 3.134

2.  Clinical and radiological outcome 1-year after cervical total disc replacement using the Signus ROTAIO - Prosthesis.

Authors:  Anna Lang; Sara Lener; Lukas Grassner; Anto Abramovic; Claudius Thomé; Dennis Päsler; Jens Lehmberg; Ralph Schär; Sebastian Hartmann
Journal:  Eur Spine J       Date:  2022-10-11       Impact factor: 2.721

3.  Mid-long-term follow-up of operated level kinematics after single-level artificial cervical disc replacement with Bryan disc.

Authors:  Chuanhong Li; Xing Yu; Yang Xiong; Yongdong Yang; Fengxian Wang; He Zhao
Journal:  J Orthop Surg Res       Date:  2022-03-09       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.