Literature DB >> 27111277

Voltammetric Mechanism of Multiion Detection with Thin Ionophore-Based Polymeric Membrane.

Peter J Greenawalt1, Shigeru Amemiya1.   

Abstract

The capability to detect multianalyte ions in their mixed solution is an important advantage of voltammetry with an ionophore-based polymeric membrane against the potentiometric and optical counterparts. This advanced capability is highly attractive for the analysis of physiological ions at millimolar concentrations in biological and biomedical samples. Herein, we report on the comprehensive response mechanisms based on the voltammetric exchange and transfer of millimolar multiions at a thin polymeric membrane, where an ionophore is exhaustively depleted upon the transfer of the most favorable primary ion, I(zI). With a new voltammetric ion-exchange mechanism, the primary ion is exchanged with the secondary favorable ion, J(zJ), at more extreme potentials to transfer a net charge of |zJ|/nJ - |zI|/nI for each ionophore molecule, which forms 1:nI and 1:nJ complexes with the respective ions. Alternatively, an ion-transfer mechanism utilizes the second ionophore that independently transfers the secondary ion without ion exchange. Experimentally, a membrane is doped with a Na(+)- or Li(+)-selective ionophore to detect not only the primary ion, but also the secondary alkaline earth ion, based on the ion-exchange mechanism, where both ions form 1:1 complexes with the ionophores to transfer a net charge of +1. Interestingly, the resultant peak potentials of the secondary divalent ion vary with its sample activity to yield an apparently super-Nernstian slope as predicted theoretically. By contrast, the voltammetric exchange of calcium ion (nI = 3) with lithium ion (nJ = 1) by a Ca(2+)-selective ionophore is thermodynamically unfavorable, thereby requiring a Li(+)-selective ionophore for the ion-transfer mechanism.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27111277      PMCID: PMC5029862          DOI: 10.1021/acs.analchem.6b00397

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  18 in total

1.  Stripping voltammetry of nanomolar potassium and ammonium ions using a valinomycin-doped double-polymer electrode.

Authors:  Benjamin Kabagambe; Anahita Izadyar; Shigeru Amemiya
Journal:  Anal Chem       Date:  2012-08-28       Impact factor: 6.986

2.  Subnanomolar ion detection by stripping voltammetry with solid-supported thin polymeric membrane.

Authors:  Yushin Kim; Patrick J Rodgers; Ryoichi Ishimatsu; Shigeru Amemiya
Journal:  Anal Chem       Date:  2009-09-01       Impact factor: 6.986

3.  A phase boundary potential model for apparently "twice-nernstian" responses of liquid membrane ion-selective electrodes.

Authors:  S Amemiya; P Bühlmann; Y Umezawa
Journal:  Anal Chem       Date:  1998-02-01       Impact factor: 6.986

4.  Voltammetric ion-selective electrodes for the selective determination of cations and anions.

Authors:  Jie Zhang; Alexander R Harris; Robert W Cattrall; Alan M Bond
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

5.  Electrochemical mechanism of ion-ionophore recognition at plasticized polymer membrane/water interfaces.

Authors:  Ryoichi Ishimatsu; Anahita Izadyar; Benjamin Kabagambe; Yushin Kim; Jiyeon Kim; Shigeru Amemiya
Journal:  J Am Chem Soc       Date:  2011-09-20       Impact factor: 15.419

6.  Extraction or adsorption? Voltammetric assessment of protamine transfer at ionophore-based polymeric membranes.

Authors:  Mohammed B Garada; Benjamin Kabagambe; Shigeru Amemiya
Journal:  Anal Chem       Date:  2015-05-08       Impact factor: 6.986

7.  Voltammetric characterization of ion-ionophore complexation using thin polymeric membranes: asymmetric thin-layer responses.

Authors:  Peter J Greenawalt; Mohammed B Garada; Shigeru Amemiya
Journal:  Anal Chem       Date:  2015-07-30       Impact factor: 6.986

8.  Ionophore-Based Voltammetric Ion Activity Sensing with Thin Layer Membranes.

Authors:  Maria Cuartero; Gaston A Crespo; Eric Bakker
Journal:  Anal Chem       Date:  2016-01-08       Impact factor: 6.986

9.  Voltammetric heparin-selective electrode based on thin liquid membrane with conducting polymer-modified solid support.

Authors:  Jidong Guo; Shigeru Amemiya
Journal:  Anal Chem       Date:  2006-10-01       Impact factor: 6.986

10.  Subnanomolar detection limit of stripping voltammetric Ca²⁺-selective electrode: effects of analyte charge and sample contamination.

Authors:  Benjamin Kabagambe; Mohammed B Garada; Ryoichi Ishimatsu; Shigeru Amemiya
Journal:  Anal Chem       Date:  2014-07-11       Impact factor: 6.986

View more
  1 in total

1.  Voltammetric Ion Selectivity of Thin Ionophore-Based Polymeric Membranes: Kinetic Effect of Ion Hydrophilicity.

Authors:  Shigeru Amemiya
Journal:  Anal Chem       Date:  2016-08-23       Impact factor: 6.986

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.