Literature DB >> 20121252

Voltammetric ion-selective electrodes for the selective determination of cations and anions.

Jie Zhang1, Alexander R Harris, Robert W Cattrall, Alan M Bond.   

Abstract

A general theory has been developed for voltammetric ion sensing of cations and anions based on the use of an electrode coated with a membrane containing an electroactive species, an ionophore, and a supporting electrolyte dissolved in a plasticizer. In experimental studies, a membrane coated electrode is fabricated by the drop coating method. In one configuration, a glassy carbon electrode is coated with a poly(vinyl chloride) based membrane, which contains the electroactive species, ionophore, plasticizer and supporting electrolyte. In the case of a cation sensor, ionophore facilitated transfer of the target cation from the aqueous solution to the membrane phase occurs during the course of the reduction of the electroactive species present in the membrane in order to maintain charge neutrality. The formal potential is calculated from the cyclic voltammogram as the average of the reduction and oxidation peak potentials and depends on the identity and concentration of the ion present in the aqueous solution phase. A plot of the formal potential versus the logarithm of the concentration exhibits a close to Nernstian slope of RT/F millivolts per decade change in concentration when the concentration of K(+) and Na(+) is varied over the concentration range of 0.1 mM to 1 M when K(+) or Na(+) ionophores are used in the membrane. The slope is close to RT/2F millivolts for a Ca(2+) voltammetric ion-selective electrode fabricated using a Ca(2+) ionophore. The sensor measurement time is only a few seconds. Voltammetric sensors for K(+), Na(+), and Ca(2+) constructed in this manner exhibit the sensitivity and selectivity required for determination of these ions in environmentally and biologically important matrixes. Analogous principles apply to the fabrication of anion voltammetric sensors.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20121252     DOI: 10.1021/ac902296r

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Electrochemical sensors and biosensors.

Authors:  Danielle W Kimmel; Gabriel LeBlanc; Mika E Meschievitz; David E Cliffel
Journal:  Anal Chem       Date:  2011-11-11       Impact factor: 6.986

2.  Electrochemical Sensing and Imaging Based on Ion Transfer at Liquid/Liquid Interfaces.

Authors:  Shigeru Amemiya; Jiyeon Kim; Anahita Izadyar; Benjamin Kabagambe; Mei Shen; Ryoichi Ishimatsu
Journal:  Electrochim Acta       Date:  2013-11-01       Impact factor: 6.901

3.  Voltammetric Mechanism of Multiion Detection with Thin Ionophore-Based Polymeric Membrane.

Authors:  Peter J Greenawalt; Shigeru Amemiya
Journal:  Anal Chem       Date:  2016-05-09       Impact factor: 6.986

4.  Scalable approach towards specific and ultrasensitive cation sensing under harsh environmental conditions by engineering the analyte-transducer interface.

Authors:  Sudeshna Mondal; Chandramouli Subramaniam
Journal:  Nanoscale Adv       Date:  2021-05-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.