Literature DB >> 26712342

Ionophore-Based Voltammetric Ion Activity Sensing with Thin Layer Membranes.

Maria Cuartero1, Gaston A Crespo1, Eric Bakker1.   

Abstract

As shown in recent work, thin layer ion-selective multi-ionophore membranes can be interrogated by cyclic voltammetry to detect the ion activity of multiple species simultaneously and selectively. Additional fundamental evidence is put forward on ion discrimination with thin multi-ionophore-based membranes with thicknesses of 200 ± 25 nm and backside contacted with poly-3-octylthiophene (POT). An anodic potential scan partially oxidizes the POT film (to POT(+)), thereby initiating the release of hydrophilic cations from the membrane phase to the sample solution at a characteristic potential. Varying concentration of added cation-exchanger demonstrates that it limits the ion transfer charge and not the deposited POT film. Voltammograms with multiple peaks are observed with each associated with the transfer of one type of ion (lithium, potassium, and sodium). Experimental conditions (thickness and composition of the membrane and concentration of the sample) are chosen that allow one to describe the system by a thermodynamic rather than kinetic model. As a consequence, apparent stability constants for sodium, potassium, and lithium (assuming 1:1 stoichiometry) with their respective ionophores are calculated and agree well with the values obtained by the potentiometric sandwich membrane technique. As an analytical application, a membrane containing three ionophores was used to determine lithium, sodium, and potassium in artificial samples at the same location and within a single voltammetric scan. Lithium and potassium were also determined in undiluted human plasma in the therapeutic concentration range.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26712342     DOI: 10.1021/acs.analchem.5b03611

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Spectroelectrochemistry with Ultrathin Ion-Selective Membranes: Three Distinct Ranges for Analytical Sensing.

Authors:  Yujie Liu; Gastón A Crespo; María Cuartero
Journal:  Anal Chem       Date:  2022-06-10       Impact factor: 8.008

2.  Voltammetric Mechanism of Multiion Detection with Thin Ionophore-Based Polymeric Membrane.

Authors:  Peter J Greenawalt; Shigeru Amemiya
Journal:  Anal Chem       Date:  2016-05-09       Impact factor: 6.986

Review 3.  Multianalyte Physiological Microanalytical Devices.

Authors:  Anna Nix Davis; Adam R Travis; Dusty R Miller; David E Cliffel
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2017-06-12       Impact factor: 12.400

4.  Electrochemical Detection of Electrolytes Using a Solid-State Ion-Selective Electrode of Single-Piece Type Membrane.

Authors:  Li-Da Chen; Wei-Jhen Wang; Gou-Jen Wang
Journal:  Biosensors (Basel)       Date:  2021-04-07

5.  Cation Exchange Membranes Coated with Polyethyleneimine and Crown Ether to Improve Monovalent Cation Electrodialytic Selectivity.

Authors:  Shanshan Yang; Shuaijun Yu; Lu Yu; Yuanwei Liu; Junbin Liao; Jiangnan Shen; Congjie Gao
Journal:  Membranes (Basel)       Date:  2021-05-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.