Literature DB >> 27102449

Diagnostic Accuracy of Real-Time Shear Wave Elastography for Staging of Liver Fibrosis: A Meta-Analysis.

Changtian Li1, Changsheng Zhang2, Junlai Li1, Huiping Huo1, Danfei Song1.   

Abstract

BACKGROUND The present meta-analysis, based on previous studies, was aimed to evaluate the test accuracy of real-time shear wave elastography (SWE) for the staging of liver fibrosis. MATERIAL AND METHODS A systematic search on MEDLINE, PubMed, Embase, and Google Scholar databases was conducted, and data on SWE tests and liver fibrosis staging were collected. For each cut-off stage of fibrosis (F≥2, F≥3, and F≥4), pooled results of sensitivity, specificity, and area under summary receiver operating characteristic (SROC) curve were analyzed. The study heterogeneity was evaluated by χ2 and I2 tests. I2>50% or P≤0.05 indicates there was heterogeneity, and then a random-effects model was applied. Otherwise, the fixed-effects model was used. The publication bias was evaluated using Deeks funnel plots asymmetry test and Fagan plot analysis was performed. RESULTS Finally, 934 patients from 8 published studies were included in the analysis. The pooled sensitivity and specificity of SWE for F≥2 were 85.0% (95% CI, 82-88%) and 81% (95% CI, 71-88%), respectively. The area under the SROC curve with 95% CI was presented as 0.88 (95% CI, 85-91%). The pooled sensitivity and specificity of SWE for F≥3 were 90.0% (95% CI, 83.0-95.0%) and 81.0% (95% CI, 75.0-86.0%), respectively, corresponding to an area of SROC of 0.94 (95% CI, 92-96%). The pooled sensitivity and specificity of SWE for F≥4 were 87.0% (95% CI, 80.0-92.0%) and 88.0% (95% CI, 80.0-93.0%), respectively, corresponding to an area of SROC of 0.92 (95% CI, 89-94%). CONCLUSIONS The overall accuracy of SWE is high and clinically useful for the staging of liver fibrosis. Compared to the results of meta-analyses on other tests, such as RTE, TE, and ARFI, the performance of SWE is nearly identical in accuracy for the evaluation of cirrhosis. For the evaluation of significant liver fibrosis (F≥2), the overall accuracy of SWE seems to be similar to ARFI, but more accurate than RTE and TE.

Entities:  

Mesh:

Year:  2016        PMID: 27102449      PMCID: PMC4844274          DOI: 10.12659/msm.895662

Source DB:  PubMed          Journal:  Med Sci Monit        ISSN: 1234-1010


Background

In patients suffering from chronic liver diseases (CLDs), the necrosis of hepatocytes and the progression of inflammatory reaction cause liver fibrosis [1]. Without timely and appropriate intervention, the liver fibrosis gradually progresses into cirrhosis, hepatocellular carcinoma (HCC), and, ultimately, liver failure [2]. The staging, i.e., the classification and identification of stages or degree of liver fibrosis, is of major clinical concern, because it is the strongest prognostic indicator and crucial for the optimization of treatment strategies [3]. Currently, liver biopsy (LB) is considered as the criterion standard to evaluate the degree of liver fibrosis [4,5]. However, liver biopsy is an invasive method possibly causing pain, hemorrhage, and even mortality. Moreover, liver biopsy is susceptible to inter/intra-observer variability, sampling error, and other limits [6-8]. In the recent years, the advances in imaging technology have enabled quantitative and noninvasive measurements of liver stiffness with various ultrasound-based elastographic methods, including Real-time Tissue Elastography (RTE), Transient Elastography (TE) (Fibroscan; Echosense, Paris, France), Acoustic Radiation Force Impulse Imaging (ARFI; Siemens, Erlangen, Germany), and Real-time Shear Wave Elastography (SWE) (Aixplorer; Supersonic Imagine, Aix-en-Provence, France) [9-13]. Among these methods, SWE is a new real-time technique using measurements of acoustically generated tissue shear wave propagation velocity to derive the estimates of liver stiffness. SWE has the advantages of providing anatomic B-mode US images and elastographic color maps according to the degree of stiffness simultaneously, which offers the potential of enhanced accuracy in the assessment of liver stiffness [14,15]. RTE, TE, and ARFI have been evaluated in several meta-analyses for their roles in staging liver fibrosis, and were shown to have clinically satisfactory high accuracy for the diagnosis of cirrhosis but intermediate accuracy for differentiating between mild and moderate liver fibrosis [16-18]. Although an increasing number of studies have evaluated the utility of SWE in assessing the degree of liver fibrosis, wide ranges of sensitivity and specificity were reported [12,14,15,19-28]. A systematic approach to this topic integrating the SWE data from independent studies may provide a better assessment of the utility of SWE in liver fibrosis staging. Therefore, we performed a meta-analysis to assess the overall performance of SWE in the diagnosis of liver fibrosis.

Material and Methods

Search strategy

Relevant published studies present in the databases of MEDLINE, PubMed, Embase, and Google Scholar were searched using the following terms: (elastography OR shear wave elastography) AND (liver OR hepatic) AND (diagnosis OR diagnostic test). For each relevant published study thus identified, the references cited in the study were further scrutinized to obtain more related studies. Our analysis was performed in accordance with the PRISMA statement.

Study inclusion

To be included, the articles had to meet the following criteria. First, the articles assessed the effects of SWE in diagnosis of liver fibrosis stages with quantitative determination. Second, the diagnosis of liver fibrosis was confirmed using the liver biopsy as the criterion standard and the fibrosis stages were scored according to METAVIR or comparable staging systems. Third, the studies provided available data on true positive (TP), false positive (FP), false negative (FN), and true negative (TN) or reported sufficient data (sensitivity, specificity, negative predictive value [NPV] and positive predictive value [PPV]) to derive these parameters. Fourth, every study enrolled at least 30 patients. Fifth, if 2 or more publications came from the same primary study, the publication with larger the sample size was included. The methodological quality of each article was evaluated by the Quality Assessment for Studies of Diagnostic Accuracy (QUADAS) tool (Table 1).
Table 1

Quality assessment of included sutdies.

Author, yearQ1Q2Q3Q4Q5Q6Q7Q8Q9Q10Q11Q12Q13Q14QUADAS score
Spectrum compositionSelection criteriaAppropriate reference standardDisease progression biasPartial verification biasDifferential verification biasIncorporation biasTest execution detailsReference execution detailsTest review biasDiagnostic review biasClinical review biasIntermediate resultsWithdrawals
Beland et al., 2014YesYesYesYesYesYesYesYesYesYesYesYesYesYes14
Ferraioli et al., 2012YesYesYesYesYesYesYesYesYesYesYesYesYesYes14
Zeng et al., 2014YesYesYesYesYesYesYesYesYesYesYesYesYesYes14
Yoon et al., 2014YesYesYesUnclearYesYesYesYesYesUnclearYesYesYesYes12
Jeong et al., 2014YesYesYesUnclearYesYesYesYesYesYesUnclearYesYesYes12
Samir et al., 2014YesYesYesYesYesYesYesYesYesYesYesYesYesYes14
Zheng et al., 2015YesYesYesYesYesYesYesYesYesYesYesYesYesYes14
Tada et al., 2015YesYesYesUnclearYesYesYesYesYesYesYesYesYesYes13

Data extraction

Two investigators independently extracted the following data from each article using standardized forms: 1) name of first author; 2) year of publication; 3) country; 4) number of patients; 5) sex distribution; 6) mean age, 7) diagnosis of liver diseases; 8) SWE parameter; 9) measurement location; and 10) cut-off stage of fibrosis. Disagreements were resolved by discussion between the 2 investigators.

Statistical analysis

According to the METAVIR scoring system, the hepatic fibrosis could be staged into 5 groups (F0, no fibrosis; F1, portal fibrosis without septa; F2, portal fibrosis and few septa, but intact architecture; F3, numerous septa, architectural distortion, but no obvious cirrhosis; and F4, cirrhosis). Our assessments of the diagnostic accuracy were made for the discrimination of F0 versus F1–4, F0/1 versus F2–4, F0–2 versus F3/4, and F0–3 versus F4. In this study, these discriminations were also described as F≥1, F≥2, F≥3, and F≥4, respectively. Based on this, the 2×2 contingency tables including TP, FP, TN, and FN results were established. The pooled sensitivity and specificity with corresponding 95% confidence intervals (CIs) were used to analyze the degree of accuracy of SWE in identifying the stages of liver fibrosis. The summary receiver operating characteristic (SROC) curve also was used to present the results. χ2 and I2 tests were calculated to evaluate the study heterogeneity. I2>50% or P≤0.05 suggests the heterogeneity exists, and a random-effects model was applied in the analysis for the heterogenic data. Otherwise, the fixed-effects model was applied. The publication bias was assessed by Deeks funnel plot asymmetry test. Fagan plot analysis was also performed. Pre-test probabilities of 25%, 50%, and 75% were assumed. The corresponding post-test probabilities were calculated following a “positive” or “negative” result based on the summary sensitivity and specificity of SWE, which showed the relationship among the prior probability specified, the likelihood ratio, and posterior test probability [18,29]. The meta-analysis was completed in Stata 12.0 (StataCorp., College Station, TX, USA).

Results

Study characteristics

A total of 405 published studies were retrieved using the search strategy described in the methods section. We excluded 350 articles for lack of relevance, based on inspecting the abstracts. Full texts of 55 articles were obtained for further evaluation. Then, 8 articles were selected in the meta-analysis [14,15,19-22,26,27] (Figure 1). The 8 published studies were performed in the United States, Italy, China, Korea, and Japan. There were 934 patients and their ages ranged from 12 to 82 years. Diseases etiology was categorized as hepatitis C virus (HCV), hepatitis B virus (HBV), and others. All the studies used the METAVIR scoring system. The adopted diagnosis parameter was E (Young’s modulus) expressed in kPa. The features of the studies are shown in Table 2. It should be mentioned that in the study conducted by Beland et al., the liver stiffness was measured in kPa on an ultrasound machine and converted to m/s by using the conversion formula [22].
Figure 1

Flow chart for articles selection in the meta-analysis. We obtained 405 articles in the search. After 350 articles were excluded for not being related to the topic, 55 records were used for further evaluation. Finally, 8 articles were included.

Table 2

Characteristics of studies evaluating the performance of SWE for staging of liver fibrosis.

StudyAgeSample sizeMale, nDisease spectrumDetection positionCut-off stage of fibrosis
Beland et al. 2014 (America) [20]21–725025HCV, othersThe biopsy siteF≥2
Ferraioli et al. 2012 (Italy) [17]19–7612187HCVThe right lobeF≥2, F≥3, F≥4
Zeng et al. 2014 (China) [18]20–59206167HBVThe right lobeF≥2, F≥3, F≥4
Yoon et al. 2014 (Korea) [19]18–7512987HBV, HCV, othersThe right lobeF≥2
Jeong et al. 2014 (Korea) [13]12–827032HBV, HCV, othersThe right lobeF≥2, F≥3, F≥4
Samir et al. 2014 (America) [12]18–7413670HCV, othersThe right upper lobeF≥2, F≥3, F≥4
Zheng et al. 2015 (China) [24]18–67167119HBV, HCV, othersThe right lobeF≥2, F≥4
Tada et al. 2015 (Japan) [25]24–785523HCVThe right lobeF≥2

HCV – hepatitis C virus; HBV – hepatitis B virus.

Summary estimates of sensitivity and specificity

Table 3 shows the test results of SWE in identifying the stages of liver fibrosis: area under curve (AUC), cutoff values, sensitivity, and specificity. There was no study discriminating F0 versus F1–4. Therefore, the data for F≥1 were not synthesized.
Table 3

The test results of SWE in detecting the stages of liver fibrosis.

StudyDiagnosis parameterFibrosis F≥2Fibrosis F≥3Fibrosis F≥4
Cut-offSensitivity/specificity (%)AUCCut-offSensitivity/specificity (%)AUCCut-offSensitivity/specificity (%)AUC
Beland et al. 2014 [20]SWV1.87 m/s75/750.82NANA/NANANANA/NANA
Ferraioli et al. 2012 [17]E7.1 kPa90/87.50.928.7 kPa97.3/95.10.9810.4 kPa87.5/96.80.98
Zeng et al. 2014 [18]E7.2 kPa86.36/86.960.9179.1 kPa91.94/85.710.94511.7 kPa91.89/89.70.945
Yoon et al. 2014 [19]E6.65 kPa78.8/75.60.852NANA/NANANANA/NANA
Jeong et al. 2014 [13]E8.6 kPa78.2/93.30.91510.46 kPa88.6/800.91314 kPa77.3/85.40.878
Samir et al. 2014 [12]E7.29 kPa91.4/52.50.778.9 kPa76.5/76.50.829.59 kPa71.4/82.20.82
Zheng et al. 2015 [24]ENA85.7/73.90.86NANA/NANANA91.2/79.70.93
Tada et al. 2015 [25]E8.8 kPa88.9/91.90.94NANA/NANANANA/NANA

Note: SWV, shear wave velocity; E, Young’s modulus.

The 8 studies all provided quantitative values for discriminating F0/1 versus F2–4. A total of 934 patients were included in the meta-analysis. The cutoff value ranged from 6.65–8.8 kPa. The pooled analysis indicated that the overall sensitivity and specificity were 85.0% (95% CI, 82–88%) and 81% (95% CI, 71–88%), respectively (Figure 2). The area under SROC curve with 95% CI was presented as 0.88 (95% CI, 0.85–0.91) (Figure 3).
Figure 2

Forest plots of sensitivity and specificity for each study according to (A) F≥2, (B) F≥3, and (C) F≥4.

Figure 3

Summary receiver operating characteristic (SROC) curves for estimating the testing accuracy of SWE for (A) F≥2, (B) F≥3, and (C) F≥4. The AUC of SROC was 0.88 (0.85–0.91), 0.94 (0.92–0.96), and 0.92 (0.89–0.94) for F≥2, F≥3, and F≥4, respectively.

The diagnostic accuracies of SWE for F≥3 and F≥4 were also evaluated. A total of 533 patients were included to analyze the test results of SWE for F≥3. The combined outcomes revealed the test sensitivity and specificity at 90.0% (95% CI, 83.0%–95.0%) and 81.0% (95% CI, 75.0–86.0%), respectively, for F≥3 (Figure 2). The corresponding area of SROC was 0.94 (95% CI, 0.92–0.96) (Figure 3). A total of 700 patients were included to analyze the test of SWE for the detection of liver cirrhosis (F≥4). The test sensitivity and specificity of SWE were 87.0% (95% CI, 80.0–92.0%) and 88.0% (95% CI, 80.0–93.0%) (Figure 2). The area of SROC was 0.92 (95% CI, 0.89–0.94) (Figure 3).

Study heterogeneity and publication bias

In the heterogeneity test, the sensitivity of F≥2 (I2=1.16%, P=0.42), specificity of F≥3 (I2=47.32%, P=0.13) and sensitivity of F≥4 (I2=15.48%, P=0.32) showed no heterogeneity, while there were heterogeneities for specificity of F≥2 (I2=86.43%, P<0.01), sensitivity of F≥3 (I2=51.32%, P=0.10), and specificity of F≥4 (I2=78.05%, P<0.01). Therefore, the sensitivity of F≥2, specificity of F≥3 and sensitivity of F≥4 were analyzed under the fixed-effects model, while specificity of F≥2, sensitivity of F≥3 and specificity of F≥4 were analyzed under the random-effects model. According to Deeks funnel plot asymmetry test, no publication bias was detected for the analysis of F≥2, F≥3 and F≥4 (P=0.924, 0.494 and 0.343) (Figure 4).
Figure 4

The funnel plot analysis. The analyses showed no potential publication bias for analysis of (A) F≥2, (B) F≥3, and (C) F≥4 (P=0.924, 0.494, 0.343).

Fagan plot analysis

The Fagan plot demonstrated that when the pre-test probabilities were 25% or 50% or 75%, the positive post-probabilities of significant fibrosis (F≥2) were 60%, 82% and 93%, and the negative post-probabilities were 6%, 15% and 35%, respectively (Figure 5). For F≥3, when the pre-test probabilities were 25% or 50% or 75%, the positive post-probabilities were 61%, 83%, and 93%, and the negative post-probabilities were 4%, 11%, and 26%, respectively (Figure 5). For F≥4, when the pre-test probabilities was 25% or 50% or 75%, the positive post-probabilities were 70%, 88%, and 96%, and the negative post-probabilities were 5%, 13%, and 31%, respectively (Figure 5).
Figure 5

Fagan plot analysis to evaluate the clinical utility of SWE for (A) F≥2, (B) F≥3, and (C) F≥4.

Discussion

SWE, a novel ultrasound-based technique, differs from conventional elastography in which the radiation force is produced by ultrasonic beam to induce the mechanical vibrations automatically. The reliability and reproducibility of SWE does not depend on the sonographer’s ability to stress or vibrate tissue correctly. Based on the ultrafast sonographic tracking techniques and the Young’s modulus formula, the quantitative information could be delivered as an elasticity index expressed in kilopascals, and real-time elastographic color maps can be displayed, showing stiffer tissue in red and softer tissue in blue. Therefore, SWE could quantify tissue stiffness directly and can be considered as a diagnostic tool that might compensate the limitations of RTE, TE and ARFI [30]. In this meta-analysis, we evaluated the performance of SWE for the assessment of liver stiffness. To the best of our knowledge, this is the first meta-analysis on this topic. Through systematic literature search and screening process, 8 studies assessing the performance of SWE in the diagnosis of liver fibrosis satisfied the inclusion criteria. Sufficient elastographic data including the quantitative stiffness information expressed in kPa could be extracted from these studies to perform a meta-analysis. The results of our meta-analysis indicate that SWE has high diagnostic accuracy in diagnosing F≥3 (sensitivity 90%, specificity 81%), F≥4 (sensitivity 87%, specificity 88%) and relatively high accuracy in F≥2 (sensitivity 85%, specificity 81%). For any cut-off stage of the liver fibrosis, both summary specificity and sensitivity are above 80%. It should be noted that our included studies used patients who underwent liver biopsy with various liver diseases. According to Tsochatzis et al., different etiologies of liver disease might have different stiffness cut-offs for a given fibrosis stage [31]. Nierhoff et al. conducted a meta-analysis to explore the efficiency of ARFI for the staging of liver fibrosis. They reported that there was a slight trend towards higher diagnostic accuracy in studies with patients only infected with HCV than in studies with patients with different liver diseases. Further subgroup analyses showed a significantly better diagnostic accuracy for the diagnosis of severe fibrosis for the studies without HBV-infected patients than for those including HBV-infected patients. Moreover, given that patients who underwent liver biopsy represent a population biased towards more severe liver diseases, the conclusion from the current study may find more validity among patients with more severe liver diseases than those with mild liver diseases. The majority of our included studies chose the right lobe as the measurement location. Samir et al. found that the SWE Young modulus of upper right lobe showed the highest correlation with fibrosis stage [14]. When compared with the results of meta-analyses on RTE, ARFI, and TE, the pooled sensitivity and specificity of SWE (87%, 88%) seems to be similar for the diagnosis of cirrhosis (F≥4). The pooled sensitivity and specificity of RTE, ARFI, and TE were 74% and 84%, 87% and 87%, 83% and 89%, respectively. But for the diagnosis of significant fibrosis (F2), the overall accuracy of SWE is higher than that of TE and RTE, and nearly identical with ARFI. For TE and RTE, the summary sensitivities were both reported as 79% and the specificities were 78% and 76% respectively, while for ARFI, the pooled sensitivity was reported as 74% and specificity was 83% [32-34]. Differentiating significant fibrosis (F2–4) from non-significant fibrosis (F0 and F1) has considerable clinical significance for patients with CLDs, especially for the HCV patients because significant fibrosis (F≥2) at the time of diagnosis has been shown to correlate with long-term cirrhosis risk [35,36]. In this regard, SWE may fill an important void. Furthermore, the elastographic techniques, such as ARFI and TE, have some common limitations. The influence of hepatic inflammation and steatosis on the tissue stiffness is still a matter of debate. According to Rizzo et al., ARFI was not associated with alanine transaminase (ALT) or liver steatosis, while TE was significantly correlated with the ALT value. However, Bota et al. reported that at least 2 stages of liver fibrosis between ARFI results and histologic assessment were associated [37-39]. In the study of Samir et al., the authors rejected the effect of inflammation or steatosis on the fibrosis estimation with the use of SWE [14]. The overall results suggested that SWE has high accuracy in diagnosing F≥3 (sensitivity 90%, specificity 81%), F≥4 (sensitivity 87%, specificity 88%), and moderate accuracy in diagnosing F≥2 (sensitivity 85%, specificity 81%). It is also essential to know that test utility varies with disease perceived risk. Therefore, Fagan plot analysis was performed in this study. In the stage of F≥2, when the pre-test probability is 75%, 93% of the patients following “positive” results could be correctly diagnosed. However, when the pre-test probability – is 25%, there is only 60% probability of correctly diagnosing F≥2 with a “positive” result. Similarly, for the stage of F≥3, when the pre-test probability changes from 75% to 25%, the post-test probability accordingly decreases from 93% to 61%. Finally, for F≥4, the post-test probability decreases from 96% to 70%. This analysis indicates that for the staging of liver fibrosis in the low-risk population, SWE still lack appropriate accuracy. Our study has several limitations. Firstly, we only identify 8 eligible studies that met the inclusion criteria. This may be due to the fact that SWE is still a new technique and large-scale studies are required to validate the clinical use of SWE in staging of liver fibrosis. Furthermore, we could not perform subgroup analyses for various liver diseases such as HCV because of the limited number of studies. In addition, our results were generated from different etiological groups within the same analysis. It is known that the relationship between the progression of liver fibrosis and the liver elasticity varies depending on the underlying liver disease. Therefore, in future studies we encourage the researchers to be more rigorous in patient selection.

Conclusions

Our meta-analysis demonstrates that for the staging of liver fibrosis, the overall accuracy of SWE is good. Compared with the results of meta-analyses on RTE, TE, and ARFI, the performance of SWE seems to be nearly identical for the evaluation of cirrhosis. For the evaluation of significant liver fibrosis (F≥2), the overall accuracy of SWE seems to be similar to ARFI, but higher than RTE and TE. However, the conclusion is made just from the data described in this article and some meta-analyses on other elastographic techniques. Large-scale, well-designed, and multi-center studies are needed to validate the conclusion and further evaluate the potential of SWE.
  38 in total

1.  Shear-wave elastography for the estimation of liver fibrosis in chronic liver disease: determining accuracy and ideal site for measurement.

Authors:  Anthony E Samir; Manish Dhyani; Abhinav Vij; Atul K Bhan; Elkan F Halpern; Jorge Méndez-Navarro; Kathleen E Corey; Raymond T Chung
Journal:  Radiology       Date:  2014-11-13       Impact factor: 11.105

Review 2.  A systematic review of the quality of liver biopsy specimens.

Authors:  Evangelos Cholongitas; Marco Senzolo; Richard Standish; Laura Marelli; Alberto Quaglia; David Patch; Amar P Dhillon; Andrew Kenneth Burroughs
Journal:  Am J Clin Pathol       Date:  2006-05       Impact factor: 2.493

3.  Diagnostic accuracy of two-dimensional shear wave elastography for the non-invasive staging of hepatic fibrosis in chronic hepatitis B: a cohort study with internal validation.

Authors:  Jie Zeng; Guang-Jian Liu; Ze-Ping Huang; Jian Zheng; Tao Wu; Rong-Qin Zheng; Ming-De Lu
Journal:  Eur Radiol       Date:  2014-07-17       Impact factor: 5.315

4.  Performance of real-time strain elastography, transient elastography, and aspartate-to-platelet ratio index in the assessment of fibrosis in chronic hepatitis C.

Authors:  Giovanna Ferraioli; Carmine Tinelli; Antonello Malfitano; Barbara Dal Bello; Gaetano Filice; Carlo Filice; Elisabetta Above; Giorgio Barbarini; Enrico Brunetti; Willy Calderon; Marta Di Gregorio; Raffaella Lissandrin; Serena Ludovisi; Laura Maiocchi; Giuseppe Michelone; Mario Mondelli; Savino F A Patruno; Alessandro Perretti; Gianluigi Poma; Paolo Sacchi; Marco Zaramella; Mabel Zicchetti
Journal:  AJR Am J Roentgenol       Date:  2012-07       Impact factor: 3.959

5.  Utility of real-time shear wave elastography for assessing liver fibrosis in patients with chronic hepatitis C infection without cirrhosis: Comparison of liver fibrosis indices.

Authors:  Toshifumi Tada; Takashi Kumada; Hidenori Toyoda; Takanori Ito; Yasuhiro Sone; Seiji Okuda; Nozomi Tsuji; Yumi Imayoshi; Eisuke Yasuda
Journal:  Hepatol Res       Date:  2015-02-04       Impact factor: 4.288

6.  Two-dimensional shear-wave elastography and conventional US: the optimal evaluation of liver fibrosis and cirrhosis.

Authors:  Jian Zheng; Huanyi Guo; Jie Zeng; Zeping Huang; Bowen Zheng; Jie Ren; Erjiao Xu; Kai Li; Rongqin Zheng
Journal:  Radiology       Date:  2015-01-07       Impact factor: 11.105

7.  Liver fibrosis evaluation using real-time shear wave elastography: applicability and diagnostic performance using methods without a gold standard.

Authors:  Thierry Poynard; Mona Munteanu; Elena Luckina; Hugo Perazzo; Yen Ngo; Luca Royer; Larysa Fedchuk; Florence Sattonnet; Raluca Pais; Pascal Lebray; Marika Rudler; Dominique Thabut; Vlad Ratziu
Journal:  J Hepatol       Date:  2013-01-12       Impact factor: 25.083

Review 8.  [Clinical application of non-invasive diagnosis for hepatic fibrosis].

Authors:  Sung Won Cho; Jae Youn Cheong
Journal:  Korean J Hepatol       Date:  2007-06

9.  Study of detection times for liver stiffness evaluation by shear wave elastography.

Authors:  Ze-Ping Huang; Xin-Ling Zhang; Jie Zeng; Jian Zheng; Ping Wang; Rong-Qin Zheng
Journal:  World J Gastroenterol       Date:  2014-07-28       Impact factor: 5.742

10.  The role of elastosonography in the differentiation of parotid gland lesions: report of three cases and review of the literature.

Authors:  Idil Gunes Tatar; Onur Ergun; Aydin Kurt; Mustafa Sahin; Baki Hekimoğlu
Journal:  Pol J Radiol       Date:  2014-11-06
View more
  10 in total

1.  Measurement of Liver Stiffness with 2D-Shear Wave Elastography (2D-SWE) in Bariatric Surgery Candidates Reveals Acceptable Diagnostic Yield Compared to Liver Biopsy.

Authors:  Tannaz Jamialahmadi; Mohsen Nematy; Ali Jangjoo; Ladan Goshayeshi; Reza Rezvani; Kamran Ghaffarzadegan; Mehdi Jabbari Nooghabi; Payman Shalchian; Mahtab Zangui; Zeinab Javid; Saeid Doaei; Farnood Rajabzadeh
Journal:  Obes Surg       Date:  2019-08       Impact factor: 4.129

2.  Quantification of Liver Fibrosis, Steatosis, and Viscosity Using Multiparametric Ultrasound in Patients with Non-Alcoholic Liver Disease: A "Real-Life" Cohort Study.

Authors:  Alexandru Popa; Felix Bende; Roxana Șirli; Alina Popescu; Victor Bâldea; Raluca Lupușoru; Radu Cotrău; Renata Fofiu; Camelia Foncea; Ioan Sporea
Journal:  Diagnostics (Basel)       Date:  2021-04-26

Review 3.  Quantitative and noninvasive assessment of chronic liver diseases using two-dimensional shear wave elastography.

Authors:  Li-Ting Xie; Chun-Hong Yan; Qi-Yu Zhao; Meng-Na He; Tian-An Jiang
Journal:  World J Gastroenterol       Date:  2018-03-07       Impact factor: 5.742

4.  Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis.

Authors:  Dong Wook Kim; Chong Hyun Suh; Kyung Won Kim; Junhee Pyo; Chan Park; Seung Chai Jung
Journal:  Korean J Radiol       Date:  2019-06       Impact factor: 3.500

5.  Histological improvement in chronic hepatitis B patients treated with bicyclol: real world experience.

Authors:  Xiaoling Chi; Huanming Xiao; Meijie Shi; Gaoshu Cai; Yubao Xie; Junmin Jiang; Guangjun Tian; Shuduo Wu; Chaozhen Zhang; Pengtao Zhao; Jiezhen Chen
Journal:  BMC Gastroenterol       Date:  2019-06-13       Impact factor: 3.067

6.  Accuracy of real-time shear wave elastography in staging hepatic fibrosis: a meta-analysis.

Authors:  Juan Fu; Biao Wu; Huazhi Wu; Feng Lin; Wei Deng
Journal:  BMC Med Imaging       Date:  2020-02-11       Impact factor: 1.930

7.  Ultrasound shear wave elastography and liver biopsy to determine liver fibrosis in adult patients.

Authors:  Mohammad M Gharibvand; Mohammad Asare; Azim Motamedfar; Pezhman Alavinejad; Mohammad Momeni
Journal:  J Family Med Prim Care       Date:  2020-02-28

8.  Shear Wave Elastography in the Evaluation of Renal Parenchymal Stiffness in Patients With Chronic Kidney Disease: A Meta-Analysis.

Authors:  Xian Ling Mo; Hui Yan Meng; Yan Yan Wu; Xue Yan Wei; Zong Ke Li; Su Qin Yang
Journal:  J Clin Med Res       Date:  2022-02-24

9.  Value of Endobronchial Ultrasound Elastography in Diagnosis of Central Lung Lesions.

Authors:  Hai-Yan He; Jin-Liang Chen; Hang Ma; Jie Zhu; Dan-Dan Wu; Xue-Dong Lv
Journal:  Med Sci Monit       Date:  2017-07-05

Review 10.  Comparison of diagnostic accuracy of magnetic resonance elastography and Fibroscan for detecting liver fibrosis in chronic hepatitis B patients: A systematic review and meta-analysis.

Authors:  Huanming Xiao; Meijie Shi; Yubao Xie; Xiaoling Chi
Journal:  PLoS One       Date:  2017-11-06       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.