Literature DB >> 8862295

Early and delayed technetium-99m-tetrofosmin myocardial SPECT compared in normal volunteers.

I Matsunari1, Y Tanishima, J Taki, K Ono, H Nishide, S Fujino, M Matoba, K Ichiyanagi, N Tonami.   

Abstract

UNLABELLED: This study was performed to test the feasibility of early SPECT imaging with 99mTc-tetrofosmin with the presence of high hepatic activity.
METHODS: Thirteen normal volunteers were injected 600-740 MBq of 99mTc-tetrofosmin at rest and were imaged at 10 min and 1 hr after injection. The SPECT images were reconstructed for 180 degrees 360 degrees data. The early and delayed SPECT and anterior planar projection images were analyzed.
RESULTS: After excluding one subject because of high hepatic activity overlapping to the myocardium, 4 of 12 subjects (33%) had abnormal scans with reduced uptake in the inferior wall on the early 180 degrees SPECT image. In contrast, only one (8%) showed equivocally reduced uptake on the 360 degrees SPECT image. In the delayed images, all subjects had a normal 180 degrees and 360 degrees SPECT scan. Quantitative data showed reduced regional activities in the inferior wall on the early SPECT scan, especially in the 180 degrees data. There were no changes in the mean anterior-to-inferior ratio in the anterior planar projection images over time, suggesting that the reduced activity in the early SPECT images reflected an artifactual effect.
CONCLUSION: Our data indicate that it would be best to perform late imaging in patients with suspected coronary artery disease using 99mTc-tetrofosmin.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8862295

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  8 in total

1.  Organ biodistribution and myocardial uptake, washout, and redistribution kinetics of Tc-99m N-DBODC5 when injected during vasodilator stress in canine models of coronary stenoses.

Authors:  Kengo Hatada; Mirta Ruiz; Laurent M Riou; Ronaldo L Lima; Allen R Goode; Denny D Watson; George A Beller; David K Glover
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

2.  Attenuation-corrected rest thallium-201/stress technetium 99m sestamibi myocardial SPECT in normals.

Authors:  I Matsunari; G Böning; S I Ziegler; I Kosa; S G Nekolla; E P Ficaro; M Schwaiger
Journal:  J Nucl Cardiol       Date:  1998 Jan-Feb       Impact factor: 5.952

3.  Fast myocardial perfusion imaging with 99mTc in challenging patients using conventional SPECT cameras.

Authors:  Athanasios Katsikis; Athanasios Theodorakos; Anna Kouzoumi; Elpida Kitziri; Evangelos Georgiou; Maria Koutelou
Journal:  J Nucl Cardiol       Date:  2016-03-14       Impact factor: 5.952

4.  Effects of Glycosylation on Biodistribution and Imaging Quality of Necrotic Myocardium of Iodine-131-Labeled Sennidins.

Authors:  Ling Li; Dongjian Zhang; Shengwei Yang; Shaoli Song; Jindian Li; Qin Wang; Cong Wang; Yuanbo Feng; Yicheng Ni; Jian Zhang; Wei Liu; Zhiqi Yin
Journal:  Mol Imaging Biol       Date:  2016-12       Impact factor: 3.488

5.  Validation of early image acquisitions following Tc-99 m sestamibi injection using a semiconductors camera of cadmium-zinc-telluride.

Authors:  Celine Meyer; Pierre Weinmann
Journal:  J Nucl Cardiol       Date:  2016-04-20       Impact factor: 5.952

6.  Assessment of 18F-labeled mitochondrial complex I inhibitors as PET myocardial perfusion imaging agents in rats, rabbits, and primates.

Authors:  Ming Yu; Mary Guaraldi; Mikhail Kagan; Mahesh Mistry; Jennifer McDonald; Jody Bozek; Padmaja Yalamanchili; Megan Hayes; Michael Azure; Ajay Purohit; Heike Radeke; David S Casebier; Simon P Robinson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-08-21       Impact factor: 9.236

7.  Tetrofosmin early time gated post-stress single-photon emission computed tomography imaging: feasibility and potential benefits.

Authors:  Laurent Philippe; Bertrand Mérino; Tanguy Blaire; Alban Bailliez; Danielle Casset-Senon; Maurice Levy; Arnaud Halley; Guillaume Divry
Journal:  J Nucl Cardiol       Date:  2010-11-11       Impact factor: 5.952

8.  Performance of a semiconductor SPECT system: comparison with a conventional Anger-type SPECT instrument.

Authors:  Yasuyuki Takahashi; Masao Miyagawa; Yoshiko Nishiyama; Hayato Ishimura; Teruhito Mochizuki
Journal:  Ann Nucl Med       Date:  2012-09-06       Impact factor: 2.668

  8 in total