Literature DB >> 27094241

Flexural Rigidity, Taper Angle, and Contact Length Affect Fretting of the Femoral Stem Trunnion in Total Hip Arthroplasty.

Ying-Ying J Kao1, Chelsea N Koch2, Timothy M Wright2, Douglas E Padgett1.   

Abstract

BACKGROUND: Modularity at the head-neck junction in total hip arthroplasty allows for intraoperative adjustments but may be a source of metallic debris. We determined how flexural rigidity, taper angle, contact length, and lever arm affect fretting and corrosion at this junction.
METHODS: A total of 77 metal-on-polyethylene total hip arthroplasties retrieved over a 10-year period at a single institution were obtained. Head tapers and stem trunnions were graded for fretting and corrosion.
RESULTS: Stem fretting was inversely related to rigidity and taper angle, while positively correlated to contact length. Head fretting and head and stem corrosion were not associated with any of these parameters.
CONCLUSION: Design and assembly factors at the modular head-neck connection affected stem fretting among the retrieved components, suggesting that these parameters are important to consider when choosing a modular system.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  flexural rigidity; modular total hip; taper corrosion; taper fretting; total hip arthroplasty

Mesh:

Substances:

Year:  2016        PMID: 27094241     DOI: 10.1016/j.arth.2016.02.079

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Do Well-functioning THAs Retrieved at Autopsy Exhibit Evidence of Fretting and Corrosion?

Authors:  Jeffrey Lange; Amanda Wach; Chelsea N Koch; Robert H Hopper; Henry Ho; Charles A Engh; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2018-10       Impact factor: 4.176

2.  How Useful Is Magnetic Resonance Imaging in Evaluating Adverse Local Tissue Reaction?

Authors:  Douglas E Padgett; Edwin P Su; Timothy M Wright; Alissa J Burge; Hollis G Potter
Journal:  J Arthroplasty       Date:  2020-01-15       Impact factor: 4.757

3.  MRI of THA Correlates With Implant Wear and Tissue Reactions: A Cross-sectional Study.

Authors:  Matthew F Koff; Christina Esposito; Parina Shah; Mauro Miranda; Elexis Baral; Kara Fields; Thomas Bauer; Douglas E Padgett; Timothy Wright; Hollis G Potter
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

4.  Ceramic Bearings with Titanium Adapter Sleeves Implanted During Revision Hip Arthroplasty Show Minimal Fretting or Corrosion: a Retrieval Analysis.

Authors:  Chelsea N Koch; Mark Figgie; Mark P Figgie; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  HSS J       Date:  2017-06-22

5.  Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.

Authors:  Rajkumar Thangaraj; Jan Kuiper; Ralph D Perkins
Journal:  J Clin Orthop Trauma       Date:  2018-01-03

6.  Acute trunnion failure of a TMZF alloy stem with large diameter femoral heads.

Authors:  E J Fahey; E Pomeroy; F E Rowan
Journal:  J Orthop       Date:  2020-01-10

7.  In Vivo Damage of the Head-Neck Junction in Hard-on-Hard Total Hip Replacements: Effect of Femoral Head Size, Metal Combination, and 12/14 Taper Design.

Authors:  Massimiliano Baleani; Paolo Erani; Barbara Bordini; Federica Zuccheri; Mateusz Kordian Mąkosa; Dalila De Pasquale; Alina Beraudi; Susanna Stea
Journal:  Materials (Basel)       Date:  2017-07-01       Impact factor: 3.623

8.  Horror of three synergistic factors in THA: high mechanical stress, dissimilar metals, low elasticity stem: a case report.

Authors:  Seiya Ishii; Yasuhiro Homma; Takehisa Matsukawa; Tomonori Baba; Ayano Kubota; Kazuhito Yokoyama; Kazuo Kaneko; Muneaki Ishijima
Journal:  Arthroplasty       Date:  2021-10-05

9.  Effect of head size and rotation on taper corrosion in a hip simulator.

Authors:  Christian M Wight; Cari M Whyne; Earl R Bogoch; Radovan Zdero; Ryan M Chapman; Douglas W van Citters; William R Walsh; Emil Schemitsch
Journal:  Bone Jt Open       Date:  2021-11
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.