Literature DB >> 27081191

Design and Methods of a Randomized Trial of Continuous Glucose Monitoring in Persons With Type 1 Diabetes With Impaired Glycemic Control Treated With Multiple Daily Insulin Injections (GOLD Study).

Marcus Lind1, William Polonsky2, Irl B Hirsch3, Tim Heise4, Jan Bolinder5, Sofia Dahlqvist6, Nils-Gunnar Pehrsson7, Peter Moström8.   

Abstract

BACKGROUND: The majority of individuals with type 1 diabetes today have glucose levels exceeding guidelines. The primary aim of this study was to evaluate whether continuous glucose monitoring (CGM), using the Dexcom G4 stand-alone system, improves glycemic control in adults with type 1 diabetes treated with multiple daily insulin injections (MDI).
METHODS: Individuals with type 1 diabetes and inadequate glycemic control (HbA1c ≥ 7.5% = 58 mmol/mol) treated with MDI were randomized in a cross-over design to the Dexcom G4 versus conventional care for 6 months followed by a 4-month wash-out period. Masked CGM was performed before randomization, during conventional treatment, and during the wash-out period to evaluate effects on hypoglycemia, hyperglycemia, and glycemic variability. Questionnaires were used to evaluate diabetes treatment satisfaction, fear of hypoglycemia, hypoglycemia confidence, diabetes-related distress, overall well-being, and physical activity during the different phases of the trial. The primary endpoint was the difference in HbA1c at the end of each treatment phase.
RESULTS: A total of 205 patients were screened, of whom 161 were randomized between February and December 2014. Study completion is anticipated in April 2016.
CONCLUSIONS: It is expected that the results of this study will establish whether using the Dexcom G4 stand-alone system in individuals with type 1 diabetes treated with MDI improves glycemic control, reduces hypoglycemia, and influences quality-of-life indicators and glycemic variability.
© 2016 Diabetes Technology Society.

Entities:  

Keywords:  CGM; glycemic control; quality of life; randomized trial; type 1 diabetes mellitus

Mesh:

Substances:

Year:  2016        PMID: 27081191      PMCID: PMC5038549          DOI: 10.1177/1932296816642578

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  33 in total

1.  Diabetes treatment satisfaction questionnaire. Change version for use alongside status version provides appropriate solution where ceiling effects occur.

Authors:  C Bradley
Journal:  Diabetes Care       Date:  1999-03       Impact factor: 19.112

Review 2.  Insulin analogues.

Authors:  Irl B Hirsch
Journal:  N Engl J Med       Date:  2005-01-13       Impact factor: 91.245

3.  Psychometric evaluation of the Swedish version of the Hypoglycaemia Fear Survey.

Authors:  Therese Anderbro; Susanne Amsberg; Regina Wredling; Per-Eric Lins; Ulf Adamson; Jan Lisspers; Unn-Britt Johansson
Journal:  Patient Educ Couns       Date:  2008-05-08

4.  A clinical trial of the accuracy and treatment experience of the Dexcom G4 sensor (Dexcom G4 system) and Enlite sensor (guardian REAL-time system) tested simultaneously in ambulatory patients with type 1 diabetes.

Authors:  Viktorija Matuleviciene; Jeffrey I Joseph; Mervi Andelin; Irl B Hirsch; Stig Attvall; Aldina Pivodic; Sofia Dahlqvist; David Klonoff; Börje Haraldsson; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2014-09-18       Impact factor: 6.118

5.  Perceived accuracy in continuous glucose monitoring: understanding the impact on patients.

Authors:  William H Polonsky; Danielle Hessler
Journal:  J Diabetes Sci Technol       Date:  2014-11-10

6.  The psychometric properties of the Swedish version of the Problem Areas in Diabetes Scale (Swe-PAID-20): scale development.

Authors:  Susanne Amsberg; Regina Wredling; Per-Eric Lins; Ulf Adamson; Unn-Britt Johansson
Journal:  Int J Nurs Stud       Date:  2007-11-05       Impact factor: 5.837

7.  Assessment of diabetes-related distress.

Authors:  W H Polonsky; B J Anderson; P A Lohrer; G Welch; A M Jacobson; J E Aponte; C E Schwartz
Journal:  Diabetes Care       Date:  1995-06       Impact factor: 19.112

Review 8.  Clinical review: Realistic expectations and practical use of continuous glucose monitoring for the endocrinologist.

Authors:  Irl B Hirsch
Journal:  J Clin Endocrinol Metab       Date:  2009-04-21       Impact factor: 5.958

9.  Psychometric properties of the hypoglycemia fear survey-ii for adults with type 1 diabetes.

Authors:  Linda A Gonder-Frederick; Karen M Schmidt; Karen A Vajda; Megan L Greear; Harsimran Singh; Jaclyn A Shepard; Daniel J Cox
Journal:  Diabetes Care       Date:  2011-02-23       Impact factor: 19.112

10.  Evidence of a strong association between frequency of self-monitoring of blood glucose and hemoglobin A1c levels in T1D exchange clinic registry participants.

Authors:  Kellee M Miller; Roy W Beck; Richard M Bergenstal; Robin S Goland; Michael J Haller; Janet B McGill; Henry Rodriguez; Jill H Simmons; Irl B Hirsch
Journal:  Diabetes Care       Date:  2013-02-01       Impact factor: 19.112

View more
  6 in total

Review 1.  Improving the clinical value and utility of CGM systems: issues and recommendations : A joint statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group.

Authors:  John R Petrie; Anne L Peters; Richard M Bergenstal; Reinhard W Holl; G Alexander Fleming; Lutz Heinemann
Journal:  Diabetologia       Date:  2017-10-25       Impact factor: 10.122

Review 2.  Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.

Authors:  David Rodbard
Journal:  Diabetes Technol Ther       Date:  2017-06       Impact factor: 6.118

3.  The Association Between HbA1c and Time in Hypoglycemia During CGM and Self-Monitoring of Blood Glucose in People With Type 1 Diabetes and Multiple Daily Insulin Injections: A Randomized Clinical Trial (GOLD-4).

Authors:  Shilan Seyed Ahmadi; Klara Westman; Aldina Pivodic; Arndís F Ólafsdóttir; Sofia Dahlqvist; Irl B Hirsch; Jarl Hellman; Magnus Ekelund; Tim Heise; William Polonsky; Magnus Wijkman; Erik Schwarcz; Marcus Lind
Journal:  Diabetes Care       Date:  2020-07-08       Impact factor: 19.112

4.  Continuous glucose monitoring and glycemic control among youth with type 1 diabetes: International comparison from the T1D Exchange and DPV Initiative.

Authors:  Daniel J DeSalvo; Kellee M Miller; Julia M Hermann; David M Maahs; Sabine E Hofer; Mark A Clements; Eggert Lilienthal; Jennifer L Sherr; Martin Tauschmann; Reinhard W Holl
Journal:  Pediatr Diabetes       Date:  2018-07-01       Impact factor: 4.866

5.  A Randomized Clinical Trial of the Effect of Continuous Glucose Monitoring on Nocturnal Hypoglycemia, Daytime Hypoglycemia, Glycemic Variability, and Hypoglycemia Confidence in Persons with Type 1 Diabetes Treated with Multiple Daily Insulin Injections (GOLD-3).

Authors:  Arndís F Ólafsdóttir; William Polonsky; Jan Bolinder; Irl B Hirsch; Sofia Dahlqvist; Hans Wedel; Thomas Nyström; Magnus Wijkman; Erik Schwarcz; Jarl Hellman; Tim Heise; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2018-04-02       Impact factor: 6.118

6.  The majority of people with type 1 diabetes and multiple daily insulin injections benefit from using continuous glucose monitoring: An analysis based on the GOLD randomized trial (GOLD-5).

Authors:  Arndís F Ólafsdóttir; Jan Bolinder; Tim Heise; William Polonsky; Magnus Ekelund; Magnus Wijkman; Aldina Pivodic; Elsa Ahlén; Erik Schwarcz; Thomas Nyström; Jarl Hellman; Irl B Hirsch; Marcus Lind
Journal:  Diabetes Obes Metab       Date:  2020-12-10       Impact factor: 6.577

  6 in total