Renato Roperto1, Anna Akkus1, Ozan Akkus2, Lisa Lang1, Manoel Damiao Sousa-Neto3, Sorin Teich1, Thiago Soares Porto1. 1. Department of Comprehensive Care, School of Dental Medicine, Case Western Reserve University, Ohio 44106, USA. 2. Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, 10900 Euclid Avenue, Ohio 44106, USA. 3. Department of Restorative Dentistry, Faculty of Dentistry, University of Sao Paulo (FORP-USP), Ribeirao Preto, SP, 14024-070, Brazil.
Abstract
BACKGROUND: The aim of this study was to determine the microtensile bond strength (μTBS) of ceramic and composite computer aided design-computer aided manufacturing (CAD-CAM) blocks bonded to dentin using different adhesive strategies. MATERIALS AND METHODS: In this in vitro study, 30 crowns of sound freshly extracted human molars were sectioned horizontally 3 mm above the cementoenamel junction to produce flat dentin surfaces. Ceramic and composite CAD/CAM blocks, size 14, were sectioned into slices of 3 mm thick. Before bonding, CAD/CAM block surfaces were treated according to the manufacturer's instructions. Groups were created based on the adhesive strategy used: Group 1 (GI) - conventional resin cement + total-etch adhesive system, Group 2 (GII) - conventional resin cement + self-etch adhesive system, and Group 3 (GIII) - self-adhesive resin cement with no adhesive. Bonded specimens were stored in 100% humidity for 24h at 37C, and then sectioned with a slow-speed diamond saw to obtain 1 mm × 1 mm × 6 mm microsticks. Microtensile testing was then conducted using a microtensile tester. μTBS values were expressed in MPa and analyzed by one-way ANOVA with post hoc (Tukey) test at the 5% significance level. RESULTS: Mean values and standard deviations of μTBS (MPa) were 17.68 (±2.71) for GI/ceramic; 17.62 (±3.99) for GI/composite; 13.61 (±6.92) for GII/composite; 12.22 (±4.24) for GII/ceramic; 7.47 (±2.29) for GIII/composite; and 6.48 (±3.10) for GIII/ceramic; ANOVA indicated significant differences among the adhesive modality and block interaction (P < 0.05), and no significant differences among blocks only, except between GI and GII/ceramic. Bond strength of GIII was consistently lower (P < 0.05) than GI and GII groups, regardless the block used. CONCLUSION: Cementation of CAD/CAM restorations, either composite or ceramic, can be significantly affected by different adhesive strategies used.
BACKGROUND: The aim of this study was to determine the microtensile bond strength (μTBS) of ceramic and composite computer aided design-computer aided manufacturing (CAD-CAM) blocks bonded to dentin using different adhesive strategies. MATERIALS AND METHODS: In this in vitro study, 30 crowns of sound freshly extracted human molars were sectioned horizontally 3 mm above the cementoenamel junction to produce flat dentin surfaces. Ceramic and composite CAD/CAM blocks, size 14, were sectioned into slices of 3 mm thick. Before bonding, CAD/CAM block surfaces were treated according to the manufacturer's instructions. Groups were created based on the adhesive strategy used: Group 1 (GI) - conventional resin cement + total-etch adhesive system, Group 2 (GII) - conventional resin cement + self-etch adhesive system, and Group 3 (GIII) - self-adhesive resin cement with no adhesive. Bonded specimens were stored in 100% humidity for 24h at 37C, and then sectioned with a slow-speed diamond saw to obtain 1 mm × 1 mm × 6 mm microsticks. Microtensile testing was then conducted using a microtensile tester. μTBS values were expressed in MPa and analyzed by one-way ANOVA with post hoc (Tukey) test at the 5% significance level. RESULTS: Mean values and standard deviations of μTBS (MPa) were 17.68 (±2.71) for GI/ceramic; 17.62 (±3.99) for GI/composite; 13.61 (±6.92) for GII/composite; 12.22 (±4.24) for GII/ceramic; 7.47 (±2.29) for GIII/composite; and 6.48 (±3.10) for GIII/ceramic; ANOVA indicated significant differences among the adhesive modality and block interaction (P < 0.05), and no significant differences among blocks only, except between GI and GII/ceramic. Bond strength of GIII was consistently lower (P < 0.05) than GI and GII groups, regardless the block used. CONCLUSION: Cementation of CAD/CAM restorations, either composite or ceramic, can be significantly affected by different adhesive strategies used.
Tooth-colored ceramic restorations are becoming increasingly popular worldwide. Computer aided design/computer aided manufacturing (CAD/CAM) materials and chair-side machines that are capable of fabricating such restorations are of a particular interest so that a single dental appointment often can suffice to deliver the restoration.[123]CAD/CAM ceramic restorations are simply bonded to teeth previously prepared to receive crowns, inlays, or onlays.[4] Cavity mechanical retention is usually not required once the primary source of retention is based on the adhesive interaction with the tooth substrate.Currently, CAD/CAM blocks are available in a variety of different materials, shades, and sizes. The most common type of CAD/CAM block (feldspathic ceramic blocks) has been the subject of investigation in several studies, where strength,[56] color stainability,[7] margin fit,[8910] and other parameters were evaluated. The newly emergent leucite glass ceramic and lithium disilicate ceramic blocks are gaining popularity due to better mechanical and aesthetic properties when compared to the feldspathic ceramic.[111213] In addition to ceramic materials, CAD/CAM restorations also can be milled from composite blocks[4] and from a hybrid of composite resin and ceramic.[14] The ceramic blocks are manufactured by Vita and are a mixture of 30% by weight feldspathic crystalline particles embedded in a glassy matrix. It has a flexural strength of 112 MPa and a Young's modulus of 63 GPa.[15] Long-term clinical studies of inlays and onlays fabricated with this material have shown survival rates of 95% over 10-year of clinical life.[16] The second type of CAD/CAM block (composite blocks) are manufactured by 3M ESPE and they are made of 3M Z100 restorative material with 85% by weight ultrafinezirconia-silica ceramic particles that reinforce a highly cross-linked polymeric matrix based on Bisphenol Adiglycidyl ether dimethacrylate and (tri[ethyleneglycol] dimethacrylate). It has a flexural strength of 109 MPa and a Young's modulus of 8 GPa.[4]After completion of the tooth milling process, two separate adhesive treatments are utilized to cement the restorations. First, the inner treated surface of the restoration receives the adhesive system and the luting agent. The inner surface restoration treatments vary depending on the restoration material. For example, ceramic restoration requires 30 s etching using 10% hydrofluoric acid on the ceramic inner surface to create a micro-retentive surface. A silane coupling agent is then applied to the restoration in order to create a chemical bonding with the resin-based luting cement. For the composite restoration, a sandblasting technique with aluminum oxide (50 μm) is generally the only necessary surface treatment for this type of restorative material. On tooth surface, total-etch or self-etch adhesive techniques are employed to create an interaction with the resin luting agent. Either total-etch or self-etch adhesive techniques aim to create hybrid layer on the dentin surface. The so-called self-adhesive resin cement does not require a separate phosphoric acid application; however, previous studies have reported low bond strength on enamel and particularly on dentin.[17] Therefore, an understanding of the effects of different strategies of adhesion when cementing different CAD/CAM restoration is of paramount clinical importance and not fully explored in the literature.This study was designed to determine the microtensile bond strength of ceramic and composite CAD-CAM blocks bonded to dentin using three different adhesive strategies: (i) Conventional resin cement with total-etch adhesive technique; (ii) conventional resin cement with self-etch adhesive technique; and finally (iii) self-adhesive resin cement with no adhesives. First, we determined whether the bond strength of CAD/CAM ceramic and composite blocks are influenced by the different adhesive strategies, and second, we examined if the type of CAD/CAM block differs in terms of bonding adhesion, regardless of the adhesive strategy used.
MATERIALS AND METHODS
In this in vitro study, 30 freshly extracted human molars were sterilized via gamma radiation. Crowns of selected sound third molars were sectioned horizontally 3 mm above the cementoenamel junction to expose sound dentin on a flat surface. The sectioned teeth were examined microscopically under × 10 magnification to ensure the absence of defects or caries, and then stored for 24 h in a temperature-controlled (37°C) incubator (Boekel Analog Model 139400, PA, USA) with 100% humidity to avoid dehydration.The CAD/CAM ceramic (Vita Mark II, Vita, Postfach, Germany) and composite blocks (Paradigm, 3M ESPE, St. Paul, MN, USA) were sectioned into 3 mm thick slices using a slow-speed saw equipped with a water-cooled diamond blade (IsoMet 1000-Buehler, Lake Bluff, IL, USA). For the ceramic blocks, one side was treated with 5% hydrofluoric acid (Cerec Ceramic Etch, Vita, CA, USA) for 30 s, then rinsed and air-dried. Two layers of silane coupling agent (Monobond Plus - IvoclairVivadent, Amherst, NY, USA) were applied to the etched surface for 30 s using a microbrush (Microbrush International, Grafton, Wi, USA) and air-dried. For the composite block, one side was sandblasted with a 50 μm aluminum oxide jet (A.E. Aubin 1400 RC, New Milford, CT, USA) for 5 s and cleaned in an ultrasonic unit for 5 min (Branson Ultrasonic Cleaner, Danbury, CT, USA).For this study, three different adhesive strategies were selected: (i) Conventional resin cement with total-etch adhesive system (Calibra + conventional bottle Primer and Bond NT associated with primer and Bond activator - Dentsply) and labelled Group 1 (GI) (n = 30); (ii) conventional resin cement with a self-etch adhesive system (Panavia F2.0 + Clearfil SE Bond - Kuraray) and called Group 2 (GII) (n = 30); (iii) self-adhesive resin cement without adhesive system (SmartCem2 - Dentsply) called Group 3 (GIII) (n = 30).For GI, teeth were etched with 34% phosphoric acid (Caulk Tooth Conditioner Gel 34%, Dentsply Caulk, Milford, DE, USA) for 30 s (enamel) and 15 s (dentin) and then rinsed for 30 s with distilled water. Both enamel and dentin were air-dried, avoiding complete dehydration of the surfaces. Adhesive system and resin cement were mixed and applied following the manufacturer's instructions [Table 1].
Table 1
Resin cements tested in this study
Resin cements tested in this studyFor GII, enamel and dentin etching techniques with phosphoric acid were not necessary. Self-etch adhesive and resin cement were applied according to the manufacturer's instructions.For GIII, neither enamel nor dentin were etched or received adhesive application. The resin cement was mixed and applied following the manufacturer's instructions.For all groups, ceramic and composite CAD/CAM block slices were bonded to the teeth under a constant seating force of approximately 50 N for 5 min using a special device designed to simulate finger pressure and equipped with a 5 kg weight whereas a high power L.E.D. light curing unit (SmartLite Max LED Curing Light, Dentsply Caulk, Milford, DE, USA) was used to cure the resin cements. Each surface of the teeth (buccal, lingual, mesial, and distal) was exposed to the light for 20 s. Then, teeth were stored in distilled water for 24 h at 37°C.The teeth were then sectioned into rectangular microsticks (6 mm × 1 mm × 1 mm) using a slow-speed saw with a water-cooled 40 micron diamond blade (MTI, Richmond, CA, USA). Only microsticks from the most central portion of the dentin were used. The microsticks were bonded onto a specially designed metal apparatus using all-purpose Super Glue (Loctite, Westlake, Ohio, USA) and placed onto a tensile tester machine (BiscoMicrotensile Tester T-61010K, Schaumburg, Illinois, USA), where the bond strength was tested with a cross speed of 0.5 mm/min. Thirty unbroken microsticks were tested per cement group (n = 90). Using a stereomicroscope at × 35 magnification (Nikon SMZ445, Melville, NY, USA) microsticks were also submitted for a failure analysis [Figure 1].
Figure 1
Steps for fabrication of the rectangular microsticks (ceramic and composite).
Steps for fabrication of the rectangular microsticks (ceramic and composite).Microtensile data were expressed in Mega Pascal (MPa), by dividing the load at failure (Newton) to the bonding surface area (mm2) and analysed by a Statistical Software (SPSS version 22.0, IBM Software, Armonk, NY, USA) using two-way ANOVA with post hoc (Tukey) test at the 95% confidence.
RESULTS
The μTBS mean values, standard deviations, and results of comparisons among different interactions are presented in Table 2 and statistical analysis (two-way ANOVA) in Table 3. ANOVA revealed significant differences among the adhesive strategy groups and adhesive strategy + blocks interaction (P < 0.05); graphically presented in [Figure 2] and then the Tukey post hoc test was applied to identify whether these differences occur. No significant differences between types of blocks only were found, except when the comparisons are among the strategy GII/ceramic block and strategy GI/ceramic and composite blocks. The GII showed better interaction when used with CAD/CAM composite block. Bond strength of GII was consistently lower than GI group regardless of the block used; however, no statistical significance (P > 0.05) was found when strategy GII/composite blocks only was compared with GI/ceramic or composite blocks; consequently, the strategy GII/ceramic blocks showed statistical significant differences when compared with strategy GI. Furthermore, the strategy GIII, which was consistently lower than GII, showed the statistical significant difference (P < 0.05), regardless of the block used; graphically represented in Figure 3. For all groups, specimens failed predominantly at the interface resin cement-dentin.
Table 2
Mean bond strength values (±SD) of investigated adhesive strategies and CAD/CAM blocks
Table 3
Two-way ANOVA values
Figure 2
Bond strength results for different adhesive strategies used.
Figure 3
Comparison of evaluated adhesive strategies only.
Mean bond strength values (±SD) of investigated adhesive strategies and CAD/CAM blocksTwo-way ANOVA valuesBond strength results for different adhesive strategies used.Comparison of evaluated adhesive strategies only.
DISCUSSION
This research was designed to determine if the bond strength of CAD/CAM ceramic and composite blocks to dentin is influenced by different adhesive strategies. Our results show that these strategies do in fact influence bond strength. Based on this study, the conventional adhesive method using resin cement associated with a total-etch adhesive system is still the best option when cementing CAD/CAM restorations.The second question was whether the different types of CAD/CAM block differ in terms of bonding adhesion, irrespective of the adhesive strategy used. The type of block turned out to be irrelevant.One of the main advantages of CAD/CAM technology is the fact that restorations can be delivered in a single dental appointment avoiding the necessity of temporary restorations, final impressions, and lab phase. Clinicians are always looking for a simpler and faster bonding technique when dealing with cementation of indirect restorations. In our study, the total-etch adhesive (GI) showed the best values in terms of bonding adhesion when used with resin cement. However, this technique is time consuming requiring the application of different products onto the tooth surface before seating the restoration.Newer self-adhesive resin cement have the potential to simplify into a single-step the bonding process to cement indirect restorations. These new cement introduced successful integration of components from different material classes such as glass ionomer and composite resin cement technologies. Self-adhesive materials are based on a great quantity of acidic methacrylate monomers with phosphoric acid groups and reactive carbon double bonds.[17] Once in contact with the tooth structure, these phosphoric acid groups of the methacrylate monomers bond to Ca2+ ions in the tooth structure. At the same time, single monomer molecules are chemically cross-linked to form a polymer network, completing the polymerization reaction.[18] However, the use of self-adhesive resin cement to bond indirect restoration is controversial. Some authors believe that the methacrylate phosphoric esters cannot adequately penetrate the partly dissolved smear layer retained on the dentin, resulting in interfacial gaps and, consequently, lower bond strength.[19]Although GII seems to be more successful than the GIII strategy in terms of bonding adhesion, previous studies have shown that the use of self-etching primers may behave as permeable membranes after polymerization, because of their higher concentration of hydrophilic and ionic resin monomers.[20] These studies also suggested the desirability of a subsequent application of a more hydrophobic resin coating layer on top of the self-etch adhesive in order to decrease the permeability and water diffusion from an adhesive-composite interface. Furthermore, other authors reported that the 10-MDP phosphate-based functional monomer present in the Clearfil SE bond system showed a good chemical interaction with the hydroxyapatite left around the collagen within the hybrid layer and this interaction appears to be important for long-term adhesive stability.[21] Therefore, the bonding adhesion between MDP and hydroxyapatite is stable due to the low solubility of the MDP-calcium salt in water.[22] In contrast, some authors have reported that self-etch adhesive systems have low interaction with enamel hydroxyapatite and an additional pretreatment of the enamel with 37% phosphoric acid for 30 s before adhesive application should be performed.[2324] Although our study was limited to only dentin surface, further studies on enamel should be performed using the same methodology.Our study also showed that composite and ceramic blocks have similar bonding adhesion with resin cement, regardless the adhesive strategy used. Both ceramic and composite surface treatment indeed improved the surface roughness and interaction with the resin cement.
CONCLUSION
In light of the fact that differences in bonding strategies can interfere with the survivability of CAD/CAM restoration, our results should be tested in a clinical setting in future studies. Finally, cementation of CAD/CAM restorations, either composite or ceramic, can be significantly affected by different adhesive strategies.
Financial support and sponsorship
Nil.
Conflicts of interest
The authors of this manuscript declare that they have no conflicts of interest, real or perceived, financial or non-financial in this article.
Authors: Marcela Riguera Pivetta; Sandra Kiss Moura; Lucia Pereira Barroso; Antonio Carlos Lascala; Alessandra Reis; Alessandro Dourado Loguercio; Rosa Helena Miranda Grande Journal: J Esthet Restor Dent Date: 2008 Impact factor: 2.843
Authors: Claudio Poggio; Andrea Scribante; Federica Della Zoppa; Marco Colombo; Riccardo Beltrami; Marco Chiesa Journal: Dent Traumatol Date: 2013-01-09 Impact factor: 3.333