PURPOSE: This study tested the materials available on the market for Cerec CAD/CAM, comparing the mean flexural strength in an ISO standardized set-up, since the ISO standard for testing such materials was issued later than the marketing of the materials tested.
METHODS: Following the recent Standard ISO 6872:2008, eight types of ceramic blocks were tested: Paradigm C, IPS Empress CAD LT, IPS Empress CAD Multi, Cerec Blocs, Cerec Blocs PC, Triluxe, Triluxe Forte, Mark II. Specimens were cut out from ceramic blocks, finished, polished, and tested in a three-point bending test apparatus until failure. Flexural strength, Weibull characteristic strength, and Weibull modulus, were calculated.
RESULTS: The results obtained from the materials for flexural strength were IPS Empress CAD (125.10 +/- 13.05), Cerec Blocs (112.68 +/- 7.97), Paradigm C (109.14 +/- 10.10), Cerec Blocs PC (105.40 +/- 5.39), Triluxe Forte (105.06 +/- 4.93), Mark II (102.77 +/- 3.60), Triluxe (101.95 +/- 7.28) and IPS Empress CAD Multi (100.86 +/- 15.82). All the tested materials had a flexural strength greater than 100 MPa, thereby satisfying the requirements of the ISO standard for the clinical indications of the materials tested. In all tested materials the Weibull characteristic strength was greater than 100 MPa.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24479276

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  8 in total

1.  CEREC CAD/CAM Chairside System.

Authors:  G Sannino; F Germano; L Arcuri; E Bigelli; C Arcuri; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2015-04-13

Review 2.  Assessment of Chair-side Computer-Aided Design and Computer-Aided Manufacturing Restorations: A Review of the Literature.

Authors:  Kusai Baroudi; Shukran Nasser Ibraheem
Journal:  J Int Oral Health       Date:  2015-04

Review 3.  Dental biomaterials for chairside CAD/CAM: State of the art.

Authors:  Hugo Lambert; Jean-Cédric Durand; Bruno Jacquot; Michel Fages
Journal:  J Adv Prosthodont       Date:  2017-12-14       Impact factor: 1.904

4.  Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study.

Authors:  Hattanas Kumchai; Patrapan Juntavee; Arthur F Sun; Dan Nathanson
Journal:  Dent J (Basel)       Date:  2020-04-27

5.  A pilot trial on lithium disilicate partial crowns using a novel prosthodontic functional index for teeth (FIT).

Authors:  Edoardo Ferrari Cagidiaco; Simone Grandini; Cecilia Goracci; Tim Joda
Journal:  BMC Oral Health       Date:  2019-12-09       Impact factor: 2.757

6.  Clinical Evaluation of Time Efficiency and Fit Accuracy of Lithium Disilicate Single Crowns between Conventional and Digital Impression.

Authors:  Ji-Su Park; Young-Jun Lim; Bongju Kim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  Materials (Basel)       Date:  2020-11-30       Impact factor: 3.623

7.  Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin.

Authors:  Renato Roperto; Anna Akkus; Ozan Akkus; Lisa Lang; Manoel Damiao Sousa-Neto; Sorin Teich; Thiago Soares Porto
Journal:  Dent Res J (Isfahan)       Date:  2016 Mar-Apr

8.  The Application of a Novel Ceramic Liner Improves Bonding between Zirconia and Veneering Porcelain.

Authors:  Hee-Sung Lee; Tae-Yub Kwon
Journal:  Materials (Basel)       Date:  2017-09-02       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.