Literature DB >> 27070243

Staging Sleep in Polysomnograms: Analysis of Inter-Scorer Variability.

Magdy Younes1,2,3, Jill Raneri2, Patrick Hanly2.   

Abstract

STUDY
OBJECTIVES: To determine the reasons for inter-scorer variability in sleep staging of polysomnograms (PSGs).
METHODS: Fifty-six PSGs were scored (5-stage sleep scoring) by 2 experienced technologists, (first manual, M1). Months later, the technologists edited their own scoring (second manual, M2) based upon feedback from the investigators that highlighted differences between their scoring. The PSGs were then scored with an automatic system (Auto) and the technologists edited them, epoch-by-epoch (Edited-Auto). This resulted in 6 different manual scores for each PSG. Epochs were classified as scorer errors (one M1 score differed from the other 5 scores), scorer bias (all 3 scores of each technologist were similar, but differed from the other technologist) and equivocal (sleep scoring was inconsistent within and between technologists).
RESULTS: Percent agreement after M1 was 78.9% ± 9.0% and was unchanged after M2 (78.1% ± 9.7%) despite numerous edits (≈40/PSG) by the scorers. Agreement in Edited-Auto was higher (86.5% ± 6.4%, p < 1E-9). Scorer errors (< 2% of epochs) and scorer bias (3.5% ± 2.3% of epochs) together accounted for < 20% of M1 disagreements. A large number of epochs (92 ± 44/PSG) with scoring agreement in M1 were subsequently changed in M2 and/or Edited-Auto. Equivocal epochs, which showed scoring inconsistency, accounted for 28% ± 12% of all epochs, and up to 76% of all epochs in individual patients. Disagreements were largely between awake/NREM, N1/N2, and N2/N3 sleep.
CONCLUSION: Inter-scorer variability is largely due to epochs that are difficult to classify. Availability of digitally identified events (e.g., spindles) or calculated variables (e.g., depth of sleep, delta wave duration) during scoring may greatly reduce scoring variability.
© 2016 American Academy of Sleep Medicine.

Entities:  

Keywords:  PSG; automated scoring; inter-observer variability; sleep stages

Mesh:

Year:  2016        PMID: 27070243      PMCID: PMC4877322          DOI: 10.5664/jcsm.5894

Source DB:  PubMed          Journal:  J Clin Sleep Med        ISSN: 1550-9389            Impact factor:   4.062


  21 in total

1.  Assessment of automated scoring of polysomnographic recordings in a population with suspected sleep-disordered breathing.

Authors:  Stephen D Pittman; Mary M MacDonald; Robert B Fogel; Atul Malhotra; Koby Todros; Baruch Levy; Amir B Geva; David P White
Journal:  Sleep       Date:  2004-11-01       Impact factor: 5.849

2.  Utility of Technologist Editing of Polysomnography Scoring Performed by a Validated Automatic System.

Authors:  Magdy Younes; Wayne Thompson; Colleen Leslie; Tanya Egan; Eleni Giannouli
Journal:  Ann Am Thorac Soc       Date:  2015-08

3.  Performance of an automated polysomnography scoring system versus computer-assisted manual scoring.

Authors:  Atul Malhotra; Magdy Younes; Samuel T Kuna; Ruth Benca; Clete A Kushida; James Walsh; Alexandra Hanlon; Bethany Staley; Allan I Pack; Grace W Pien
Journal:  Sleep       Date:  2013-04-01       Impact factor: 5.849

4.  An E-health solution for automatic sleep classification according to Rechtschaffen and Kales: validation study of the Somnolyzer 24 x 7 utilizing the Siesta database.

Authors:  Peter Anderer; Georg Gruber; Silvia Parapatics; Michael Woertz; Tatiana Miazhynskaia; Gerhard Klosch; Bernd Saletu; Josef Zeitlhofer; Manuel J Barbanoj; Heidi Danker-Hopfe; Sari-Leena Himanen; Bob Kemp; Thomas Penzel; Michael Grozinger; Dieter Kunz; Peter Rappelsberger; Alois Schlogl; Georg Dorffner
Journal:  Neuropsychobiology       Date:  2005-04-18       Impact factor: 2.328

5.  Process and outcome for international reliability in sleep scoring.

Authors:  Xiaozhe Zhang; Xiaosong Dong; Jan W Kantelhardt; Jing Li; Long Zhao; Carmen Garcia; Martin Glos; Thomas Penzel; Fang Han
Journal:  Sleep Breath       Date:  2014-05-07       Impact factor: 2.816

6.  Scoring variability between polysomnography technologists in different sleep laboratories.

Authors:  Nancy A Collop
Journal:  Sleep Med       Date:  2002-01       Impact factor: 3.492

7.  Interrater reliability between scorers from eight European sleep laboratories in subjects with different sleep disorders.

Authors:  Heidi Danker-Hopfe; D Kunz; G Gruber; G Klösch; J L Lorenzo; S L Himanen; B Kemp; T Penzel; J Röschke; H Dorn; A Schlögl; E Trenker; G Dorffner
Journal:  J Sleep Res       Date:  2004-03       Impact factor: 3.981

8.  Agreement in computer-assisted manual scoring of polysomnograms across sleep centers.

Authors:  Samuel T Kuna; Ruth Benca; Clete A Kushida; James Walsh; Magdy Younes; Bethany Staley; Alexandra Hanlon; Allan I Pack; Grace W Pien; Atul Malhotra
Journal:  Sleep       Date:  2013-04-01       Impact factor: 5.849

9.  Expert and crowd-sourced validation of an individualized sleep spindle detection method employing complex demodulation and individualized normalization.

Authors:  Laura B Ray; Stéphane Sockeel; Melissa Soon; Arnaud Bore; Ayako Myhr; Bobby Stojanoski; Rhodri Cusack; Adrian M Owen; Julien Doyon; Stuart M Fogel
Journal:  Front Hum Neurosci       Date:  2015-09-24       Impact factor: 3.169

10.  Automatic Sleep Spindle Detection and Genetic Influence Estimation Using Continuous Wavelet Transform.

Authors:  Marek Adamczyk; Lisa Genzel; Martin Dresler; Axel Steiger; Elisabeth Friess
Journal:  Front Hum Neurosci       Date:  2015-11-19       Impact factor: 3.169

View more
  31 in total

1.  Performance of a New Portable Wireless Sleep Monitor.

Authors:  Magdy Younes; Marc Soiferman; Wayne Thompson; Eleni Giannouli
Journal:  J Clin Sleep Med       Date:  2017-02-15       Impact factor: 4.062

2.  Minimizing Interrater Variability in Staging Sleep by Use of Computer-Derived Features.

Authors:  Magdy Younes; Patrick J Hanly
Journal:  J Clin Sleep Med       Date:  2016-10-15       Impact factor: 4.062

3.  Reliability of the American Academy of Sleep Medicine Rules for Assessing Sleep Depth in Clinical Practice.

Authors:  Magdy Younes; Samuel T Kuna; Allan I Pack; James K Walsh; Clete A Kushida; Bethany Staley; Grace W Pien
Journal:  J Clin Sleep Med       Date:  2018-02-15       Impact factor: 4.062

4.  Noninvasive three-state sleep-wake staging in mice using electric field sensors.

Authors:  H Kloefkorn; L M Aiani; A Lakhani; S Nagesh; A Moss; W Goolsby; J M Rehg; N P Pedersen; S Hochman
Journal:  J Neurosci Methods       Date:  2020-06-30       Impact factor: 2.390

Review 5.  Wearable Sleep Technology in Clinical and Research Settings.

Authors:  Massimiliano de Zambotti; Nicola Cellini; Aimée Goldstone; Ian M Colrain; Fiona C Baker
Journal:  Med Sci Sports Exerc       Date:  2019-07       Impact factor: 5.411

6.  The Accuracy, Night-to-Night Variability, and Stability of Frontopolar Sleep Electroencephalography Biomarkers.

Authors:  Daniel J Levendowski; Luigi Ferini-Strambi; Charlene Gamaldo; Mindy Cetel; Robert Rosenberg; Philip R Westbrook
Journal:  J Clin Sleep Med       Date:  2017-06-15       Impact factor: 4.062

Review 7.  Reinventing polysomnography in the age of precision medicine.

Authors:  Diane C Lim; Diego R Mazzotti; Kate Sutherland; Jesse W Mindel; Jinyoung Kim; Peter A Cistulli; Ulysses J Magalang; Allan I Pack; Philip de Chazal; Thomas Penzel
Journal:  Sleep Med Rev       Date:  2020-03-20       Impact factor: 11.609

8.  Noncontact identification of sleep-disturbed breathing from smartphone-recorded sounds validated by polysomnography.

Authors:  Sanjiv Narayan; Priyanka Shivdare; Tharun Niranjan; Kathryn Williams; Jon Freudman; Ruchir Sehra
Journal:  Sleep Breath       Date:  2018-07-18       Impact factor: 2.816

9.  Sleep-wake parameters can be detected in patients with chronic stroke using a multisensor accelerometer: a validation study.

Authors:  Elie Gottlieb; Leonid Churilov; Emilio Werden; Thomas Churchward; Matthew P Pase; Natalia Egorova; Mark E Howard; Amy Brodtmann
Journal:  J Clin Sleep Med       Date:  2021-02-01       Impact factor: 4.062

10.  The aging slow wave: a shifting amalgam of distinct slow wave and spindle coupling subtypes define slow wave sleep across the human lifespan.

Authors:  Brice V McConnell; Eugene Kronberg; Peter D Teale; Stefan H Sillau; Grace M Fishback; Rini I Kaplan; Angela J Fought; A Ranjitha Dhanasekaran; Brian D Berman; Alberto R Ramos; Rachel L McClure; Brianne M Bettcher
Journal:  Sleep       Date:  2021-10-11       Impact factor: 5.849

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.