Assessment of automated scoring of polysomnographic recordings in a population with suspected sleep-disordered breathing.

Stephen D Pittman1, Mary M MacDonald, Robert B Fogel, Atul Malhotra, Koby Todros, Baruch Levy, Amir B Geva, David P White.   

Abstract

STUDY
OBJECTIVES: To assess the accuracy of an automated system (Morpheus I Sleep Scoring System) for analyzing and quantifying polysomnographic data from a population with sleep-disordered breathing.
SETTING: Sleep laboratory affiliated with a tertiary care academic medical center. MEASUREMENTS AND
RESULTS: 31 diagnostic polysomnograms were blindly analyzed prospectively with the investigational automated system and manually by 2 registered polysomnography technologists (M1 & M2) from the same laboratory. Sleep stages, arousals, periodic limb movements, and respiratory events (apneas and hypopneas) were scored by all 3. Agreement, Cohen kappa, and intraclass correlation coefficients were tabulated for each variable and compared between scoring pairs (A-M1, A-M2, M1-M2). The 26,876 epochs (224 hours of recording time) were analyzed. For sleep staging, agreement/kappa were A-M1: 78%/0.67, A-M2: 73%/0.61, and M1-M2: 82%/0.73. The mean respiratory disturbance indexes were M1: 20.6+/-23.0, M2: 22.5+/-24.5, and A: 23.7+/-23.4 events per hour of sleep. The respiratory disturbance index concordance between each scoring pair was excellent (intraclass correlation coefficients > or = 0.95 for all pairs), although there was disagreement in the classification of moderate sleep-disordered breathing (percentage of positive agreement: A-M1, 37.5% and A-M2, 44.4%) defined as a respiratory disturbance index between 15 and 30 events per hour of sleep. For respiratory-event detection, agreement/kappa were A-M1 and A-M2: 90%/0.66 and M1-M2: 95%/0.82. The agreement and kappa for limb movement detection were A-M1: 93%/0.68, A-M2: 92%/0.66, and M1-M2: 96%/0.77. The scoring of arousals was less reliable (agreement range: 76%-84%, kappa range: 0.28-0.57) for all pairs.
CONCLUSIONS: Agreement between manual scorers in a population with moderate sleep-disordered breathing was close to the average pairwise agreement of 87% reported in the Sleep Heart Health Study. The automated classification of sleep stages was also close to this standard. The automated scoring system holds promise as a rapid method to score polysomnographic records, but expert verification of the automated scoring is required.

Entities:  

Mesh:

Year:  2004        PMID: 15586793     DOI: 10.1093/sleep/27.7.1394

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  32 in total

1.  Development of the National Healthy Sleep Awareness Project Sleep Health Surveillance Questions.

Authors:  Timothy I Morgenthaler; Janet B Croft; Leslie C Dort; Lauren D Loeding; Janet M Mullington; Sherene M Thomas
Journal:  J Clin Sleep Med       Date:  2015-09-15       Impact factor: 4.062

Review 2.  The why, when and how to test for obstructive sleep apnea in patients with atrial fibrillation.

Authors:  Lien Desteghe; Jeroen M L Hendriks; R Doug McEvoy; Ching Li Chai-Coetzer; Paul Dendale; Prashanthan Sanders; Hein Heidbuchel; Dominik Linz
Journal:  Clin Res Cardiol       Date:  2018-04-12       Impact factor: 5.460

3.  Fully parametric sleep staging compatible with the classical criteria.

Authors:  Urszula Malinowska; Hubert Klekowicz; Andrzej Wakarow; Szymon Niemcewicz; Piotr J Durka
Journal:  Neuroinformatics       Date:  2009-12

4.  Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System.

Authors:  Naresh M Punjabi; Naima Shifa; Georg Dorffner; Susheel Patil; Grace Pien; Rashmi N Aurora
Journal:  Sleep       Date:  2015-10-01       Impact factor: 5.849

5.  Inter-expert and intra-expert reliability in sleep spindle scoring.

Authors:  Sabrina L Wendt; Peter Welinder; Helge B D Sorensen; Paul E Peppard; Poul Jennum; Pietro Perona; Emmanuel Mignot; Simon C Warby
Journal:  Clin Neurophysiol       Date:  2014-11-10       Impact factor: 3.708

6.  EOG-based auto-staging: less is more.

Authors:  Christian Berthomier; Marie Brandewinder
Journal:  Sleep Breath       Date:  2015-02-06       Impact factor: 2.816

7.  Performance of a New Portable Wireless Sleep Monitor.

Authors:  Magdy Younes; Marc Soiferman; Wayne Thompson; Eleni Giannouli
Journal:  J Clin Sleep Med       Date:  2017-02-15       Impact factor: 4.062

8.  Prevalence and Clinical Correlates of a Short Onset REM Period (SOREMP) during Routine PSG.

Authors:  Alyssa Cairns; Richard Bogan
Journal:  Sleep       Date:  2015-10-01       Impact factor: 5.849

9.  Performance of an automated polysomnography scoring system versus computer-assisted manual scoring.

Authors:  Atul Malhotra; Magdy Younes; Samuel T Kuna; Ruth Benca; Clete A Kushida; James Walsh; Alexandra Hanlon; Bethany Staley; Allan I Pack; Grace W Pien
Journal:  Sleep       Date:  2013-04-01       Impact factor: 5.849

10.  Artificial intelligence in sleep medicine: background and implications for clinicians.

Authors:  Cathy A Goldstein; Richard B Berry; David T Kent; David A Kristo; Azizi A Seixas; Susan Redline; M Brandon Westover
Journal:  J Clin Sleep Med       Date:  2020-04-15       Impact factor: 4.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.