Literature DB >> 27067470

Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?

Christopher Del Balso1, Matthew G Teeter2, Sok Chuen Tan1, James L Howard1, Brent A Lanting1.   

Abstract

BACKGROUND: Wear and tribocorrosion at the modular head-neck taper interface may be a cause of failure in metal-on-polyethylene total hip arthroplasty (THA). The present investigation endeavored to elucidate the effect of femoral head diameter on fretting and corrosion in retrieved head-neck tapers.
METHODS: A retrieval analysis of THA prostheses in vivo for a minimum of 1 year was performed. Twenty-three femoral heads of 32-mm diameter were matched with 28-mm heads based on time in vivo and head length (-3 mm to +8 mm). All included implants featured a single taper design from a single manufacturer. Fretting and corrosion damage scoring was performed for each implant under stereomicroscopic visualization.
RESULTS: Head diameter was observed to affect fretting (P = .01), with 32-mm femoral heads exhibiting greater total fretting scores than 28-mm heads. Fretting damage was greatest (P = .01) in the central concentric zone of the femoral head bore tapers, regardless of head diameter, length, or stem offset. No significant effect on total corrosion scores was observed for any head or stem variable. Retrieved implant total corrosion scores were positively correlated (ρ = 0.51, P < .001) with implantation time.
CONCLUSION: Increased femoral head diameter in THA may produce greater fretting damage owing to and increased head-neck moment arm. There is no associated increase in corrosion with 28-mm and 32-mm heads of this taper design. The longer a THA prosthesis is implanted, the greater the risk of damage due to corrosion.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  corrosion; fretting; metal-on-polyethylene; total hip arthroplasty; trunnionosis

Mesh:

Substances:

Year:  2016        PMID: 27067470     DOI: 10.1016/j.arth.2016.03.009

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  13 in total

Review 1.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

2.  Do Well-functioning THAs Retrieved at Autopsy Exhibit Evidence of Fretting and Corrosion?

Authors:  Jeffrey Lange; Amanda Wach; Chelsea N Koch; Robert H Hopper; Henry Ho; Charles A Engh; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2018-10       Impact factor: 4.176

3.  No Increase in Survival for 36-mm versus 32-mm Femoral Heads in Metal-on-polyethylene THA: A Registry Study.

Authors:  Georgios Tsikandylakis; Johan Kärrholm; Nils P Hailer; Antti Eskelinen; Keijo T Mäkelä; Geir Hallan; Ove Nord Furnes; Alma B Pedersen; Søren Overgaard; Maziar Mohaddes
Journal:  Clin Orthop Relat Res       Date:  2018-12       Impact factor: 4.176

Review 4.  Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation.

Authors:  Ming Han Lincoln Liow; Young-Min Kwon
Journal:  Int Orthop       Date:  2016-10-20       Impact factor: 3.075

Review 5.  Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

Authors:  Michael Morlock; Dennis Bünte; Julian Gührs; Nicholas Bishop
Journal:  HSS J       Date:  2016-09-20

Review 6.  Total hip arthroplasty instability in Italy.

Authors:  Francesco Falez; Matteo Papalia; Fabio Favetti; Gabriele Panegrossi; Filippo Casella; Gianluca Mazzotta
Journal:  Int Orthop       Date:  2016-12-20       Impact factor: 3.075

7.  Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.

Authors:  Rajkumar Thangaraj; Jan Kuiper; Ralph D Perkins
Journal:  J Clin Orthop Trauma       Date:  2018-01-03

8.  Acute trunnion failure of a TMZF alloy stem with large diameter femoral heads.

Authors:  E J Fahey; E Pomeroy; F E Rowan
Journal:  J Orthop       Date:  2020-01-10

9.  Head size in primary total hip arthroplasty.

Authors:  Georgios Tsikandylakis; Maziar Mohaddes; Peter Cnudde; Antti Eskelinen; Johan Kärrholm; Ola Rolfson
Journal:  EFORT Open Rev       Date:  2018-05-21

Review 10.  Trunnion corrosion: what surgeons need to know in 2018.

Authors:  J R Berstock; M R Whitehouse; C P Duncan
Journal:  Bone Joint J       Date:  2018-01       Impact factor: 5.082