Literature DB >> 27065719

Flexible Distributed Pressure Sensing Strip for a Urethral Catheter.

Mahdi Ahmadi1, Rajesh Rajamani1, Gerald Timm2, A S Sezen1.   

Abstract

A multi-sensor flexible strip is developed for a urethral catheter to measure distributed pressure in a human urethra. The developed sensor strip has important clinical applications in urodynamic testing for analyzing the causes of urinary incontinence in patients. There are two major challenges in the development of the sensor. First, a highly sensitive sensor strip that is flexible enough for urethral insertion into a human body is required and second, the sensor has to work reliably in a liquid in-vivo environment in the human body. Capacitive force sensors are designed and micro-fabricated using polyimide/PDMS substrates and copper electrodes. To remove the parasitic influence of urethral tissues which create fringe capacitance that can lead to significant errors, a reference fringe capacitance measurement sensor is incorporated on the strip. The sensing strip is embedded on a catheter and experimental in-vitro evaluation is presented using a bench-top pressure chamber. The sensors on the strip are able to provide the required sensitivity and range. Preliminary experimental results also show promise that by using measurements from the reference parasitic sensor on the strip, the influence of parasitics from human tissue on the pressure measurements can be removed.

Entities:  

Keywords:  capacitive sensors; catheter pressure sensors; in vivo force sensors; in vivo sensors; instrumented catheter; parasitic capacitance; urethral sensors

Year:  2015        PMID: 27065719      PMCID: PMC4824413          DOI: 10.1109/JMEMS.2015.2444992

Source DB:  PubMed          Journal:  J Microelectromech Syst        ISSN: 1057-7157            Impact factor:   2.417


  15 in total

1.  Good urodynamic practices: uroflowmetry, filling cystometry, and pressure-flow studies.

Authors:  Werner Schäfer; Paul Abrams; Limin Liao; Anders Mattiasson; Francesco Pesce; Anders Spangberg; Arthur M Sterling; Norman R Zinner; Philip van Kerrebroeck
Journal:  Neurourol Urodyn       Date:  2002       Impact factor: 2.696

2.  Urodynamic changes induced by the intravaginal electrode during pelvic floor electrical stimulation.

Authors:  Julio Resplande; Shahram Gholami; Homero Bruschini; Miguel Srougi
Journal:  Neurourol Urodyn       Date:  2003       Impact factor: 2.696

3.  Ambulatory monitoring and electronic measurement of urinary leakage in the diagnosis of detrusor instability and incontinence.

Authors:  R J Webb; P D Ramsden; D E Neal
Journal:  Br J Urol       Date:  1991-08

Review 4.  Prevalence and incidence of urinary incontinence in community-dwelling populations.

Authors:  A R Herzog; N H Fultz
Journal:  J Am Geriatr Soc       Date:  1990-03       Impact factor: 5.562

5.  Economic costs of urinary incontinence in 1995.

Authors:  T H Wagner; T W Hu
Journal:  Urology       Date:  1998-03       Impact factor: 2.649

6.  Urinary incontinence in Belgium: a population-based epidemiological survey.

Authors:  C Schulman; H Claes; J Matthijs
Journal:  Eur Urol       Date:  1997       Impact factor: 20.096

7.  Urinary incontinence among community-dwelling people aged 40 years or older in Japan: prevalence, risk factors, knowledge and self-perception.

Authors:  T Ueda; M Tamaki; S Kageyama; N Yoshimura; O Yoshida
Journal:  Int J Urol       Date:  2000-03       Impact factor: 3.369

Review 8.  Urinary incontinence, pelvic floor dysfunction, exercise and sport.

Authors:  Kari Bø
Journal:  Sports Med       Date:  2004       Impact factor: 11.136

9.  Prevalence of urinary incontinence among Spanish older people living at home.

Authors:  J Damián; J M Martín-Moreno; F Lobo; J Bonache; J Cerviño; L Redondo-Márquez; E Martínez-Agulló
Journal:  Eur Urol       Date:  1998-10       Impact factor: 20.096

10.  Ambulatory monitoring of bladder and detrusor pressure during natural filling.

Authors:  C J Griffiths; M S Assi; R A Styles; P D Ramsden; D E Neal
Journal:  J Urol       Date:  1989-09       Impact factor: 7.450

View more
  4 in total

1.  Novel Supercapacitor-Based Force Sensor Insensitive to Parasitic Noise.

Authors:  Ye Zhang; Rajesh Rajamani; Serdar Sezen
Journal:  IEEE Sens Lett       Date:  2017-10-24

2.  Instrumented Urethral Catheter and Its Ex Vivo Validation in a Sheep Urethra.

Authors:  Mahdi Ahmadi; Rajesh Rajamani; Gerald Timm; Serdar Sezen
Journal:  Meas Sci Technol       Date:  2017-01-13       Impact factor: 2.046

3.  Transparent Flexible Active Faraday Cage Enables In Vivo Capacitance Measurement in Assembled Microsensor.

Authors:  Mahdi Ahmadi; Rajesh Rajamani; Serdar Sezen
Journal:  IEEE Sens Lett       Date:  2017-08-15

Review 4.  Sensor Fusion and Smart Sensor in Sports and Biomedical Applications.

Authors:  José Jair Alves Mendes; Mário Elias Marinho Vieira; Marcelo Bissi Pires; Sergio Luiz Stevan
Journal:  Sensors (Basel)       Date:  2016-09-23       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.