Literature DB >> 1884140

Ambulatory monitoring and electronic measurement of urinary leakage in the diagnosis of detrusor instability and incontinence.

R J Webb1, P D Ramsden, D E Neal.   

Abstract

The ability of conventional artificial filling urodynamic studies (CMG) and ambulatory monitoring during natural bladder filling (AM) to detect phasic detrusor activity (detrusor instability) and incontinence was studied in 52 patients suspected on clinical grounds of having bladder dysfunction, but in whom a CMG had not provided an adequate explanation of their symptoms. Detrusor instability (DI) was found on AM in 31 patients who were not unstable on conventional CMG using the criteria of the International Continence Society: DI was diagnosed on filling in 20 patients and on provocation in a further 11. Incontinence was demonstrated by electronic nappy testing in 23 patients: 13 had urge incontinence due to DI, 7 had genuine stress incontinence alone and 3 had both genuine stress incontinence and detrusor instability. Thus DI was diagnosed significantly more frequently by AM than by CMG. Ambulatory monitoring was more sensitive in the diagnosis of instability and incontinence and it may prove to be a valuable aid in the diagnosis of bladder dysfunction not detected during conventional cystometry.

Entities:  

Mesh:

Year:  1991        PMID: 1884140     DOI: 10.1111/j.1464-410x.1991.tb15283.x

Source DB:  PubMed          Journal:  Br J Urol        ISSN: 0007-1331


  6 in total

1.  Implementation of a multi-functional ambulatory urodynamics monitoring system based on newly devised abdominal pressure measurement.

Authors:  Keo Sik Kim; Jeong Hwan Seo; Jin U Kang; Chul Gyu Song
Journal:  J Med Syst       Date:  2009-05-26       Impact factor: 4.460

2.  Instrumented Urethral Catheter and Its Ex Vivo Validation in a Sheep Urethra.

Authors:  Mahdi Ahmadi; Rajesh Rajamani; Gerald Timm; Serdar Sezen
Journal:  Meas Sci Technol       Date:  2017-01-13       Impact factor: 2.046

3.  Flexible Distributed Pressure Sensing Strip for a Urethral Catheter.

Authors:  Mahdi Ahmadi; Rajesh Rajamani; Gerald Timm; A S Sezen
Journal:  J Microelectromech Syst       Date:  2015-11-25       Impact factor: 2.417

4.  A comparative study of patient experiences of conventional fluoroscopic and four-hour ambulatory urodynamic studies.

Authors:  Seung-June Oh; Ja Hyeon Ku; Hwancheol Son; Jeong Yun Jeong
Journal:  Yonsei Med J       Date:  2006-08-31       Impact factor: 2.759

5.  Review of invasive urodynamics and progress towards non-invasive measurements in the assessment of bladder outlet obstruction.

Authors:  C J Griffiths; R S Pickard
Journal:  Indian J Urol       Date:  2009-01

6.  Urodynamic investigation by telemetry in Beagle dogs: validation and effects of oral administration of current urological drugs: a pilot study.

Authors:  Stéphanie Noël; Laurent Massart; Annick Hamaide
Journal:  BMC Vet Res       Date:  2013-10-08       Impact factor: 2.741

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.