Literature DB >> 2769860

Ambulatory monitoring of bladder and detrusor pressure during natural filling.

C J Griffiths1, M S Assi, R A Styles, P D Ramsden, D E Neal.   

Abstract

We have developed a system to perform fully ambulatory monitoring studies of the bladder. Bladder and rectal pressures are recorded during natural filling of the bladder for up to 6 hours. This system has been evaluated in 19 studies performed on 15 patients. The mean duration of the studies was 3 hours 51 minutes (standard deviation +/- 1 hour 3 minutes) and the mean number of voids per patient was 3.8 +/- 2.2. Visual inspection of the recorded data showed that subtraction of the rectal trace from the bladder trace provided a useful detrusor trace when subjects were ambulant as well as resting. When ambulant, movement caused typical peak-to-peak pressure variability in the bladder and rectal traces of approximately 30 +/- 20 cm. water (mean and standard deviation of peak-to-peak pressure for typical ambulant 5-minute sections for each patient), which after subtraction was reduced on the detrusor trace to 10 +/- 5 cm. water. The equivalent figures when resting were 9 +/- 5 cm. water, subtracting to less than 5 cm. water for the detrusor. Further measurements also were calculated for the whole of each trace. The system provided good quality recordings and should prove useful in future evaluations of natural fill urodynamic studies.

Entities:  

Mesh:

Year:  1989        PMID: 2769860     DOI: 10.1016/s0022-5347(17)38887-0

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  5 in total

Review 1.  Ambulatory monitoring.

Authors:  K Brown; P Hilton
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  1997

2.  Instrumented Urethral Catheter and Its Ex Vivo Validation in a Sheep Urethra.

Authors:  Mahdi Ahmadi; Rajesh Rajamani; Gerald Timm; Serdar Sezen
Journal:  Meas Sci Technol       Date:  2017-01-13       Impact factor: 2.046

Review 3.  Investigation of the neurogenic bladder.

Authors:  C J Fowler
Journal:  J Neurol Neurosurg Psychiatry       Date:  1996-01       Impact factor: 10.154

4.  Flexible Distributed Pressure Sensing Strip for a Urethral Catheter.

Authors:  Mahdi Ahmadi; Rajesh Rajamani; Gerald Timm; A S Sezen
Journal:  J Microelectromech Syst       Date:  2015-11-25       Impact factor: 2.417

5.  Review of invasive urodynamics and progress towards non-invasive measurements in the assessment of bladder outlet obstruction.

Authors:  C J Griffiths; R S Pickard
Journal:  Indian J Urol       Date:  2009-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.