129 Xe chemical shift in human blood and pulmonary blood oxygenation measurement in humans using hyperpolarized 129 Xe NMR.

Graham Norquay1, General Leung1, Neil J Stewart1, Jan Wolber1,2, Jim M Wild1.   

Abstract

PURPOSE: To evaluate the dependency of the 129 Xe-red blood cell (RBC) chemical shift on blood oxygenation, and to use this relation for noninvasive measurement of pulmonary blood oxygenation in vivo with hyperpolarized 129 Xe NMR.
METHODS: Hyperpolarized 129 Xe was equilibrated with blood samples of varying oxygenation in vitro, and NMR was performed at 1.5 T and 3 T. Dynamic in vivo NMR during breath hold apnea was performed at 3 T on two healthy volunteers following inhalation of hyperpolarized 129 Xe.
RESULTS: The 129 Xe chemical shift in RBCs was found to increase nonlinearly with blood oxygenation at 1.5 T and 3 T. During breath hold apnea, the 129 Xe chemical shift in RBCs exhibited a periodic time modulation and showed a net decrease in chemical shift of ∼1 ppm over a 35 s breath hold, corresponding to a decrease of 7-10 % in RBC oxygenation. The 129 Xe-RBC signal amplitude showed a modulation with the same frequency as the 129 Xe-RBC chemical shift.
CONCLUSION: The feasibility of using the 129 Xe-RBC chemical shift to measure pulmonary blood oxygenation in vivo has been demonstrated. Correlation between 129 Xe-RBC signal and 129 Xe-RBC chemical shift modulations in the lung warrants further investigation, with the aim to better quantify temporal blood oxygenation changes in the cardiopulmonary vascular circuit. Magn Reson Med 77:1399-1408, 2017.
© 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  129Xe spectroscopy; blood NMR; chemical shift; hyperpolarized gases; in vivo lung

Mesh:

Substances:

Year:  2016        PMID: 27062652      PMCID: PMC5363245          DOI: 10.1002/mrm.26225

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


INTRODUCTION

Knowledge of tissue oxygenation can provide valuable insight into the pathophysiology of a spectrum of diseases. For example, in the discrimination of the penumbra following stroke 1 or identification of ischemia following myocardial infarction 2. Furthermore, hypoxia limits the efficacy of radiotherapy in the treatment of tumors 3. In lung diseases such as asthma and chronic obstructive pulmonary disease, hypoxia can influence the lifetime and the functionality of neutrophils that are associated with inflammation in the lungs 4. Surface blood oxygenation can be measured with an infrared finger probe, but this approach is depth‐limited. The accepted gold standard method of determining deep tissue oxygenation is with polarographic electrodes, as pioneered in the late 1950s 5. This invasive method, however, samples only a small amount of tissue and is able to provide assessment of oxygenation for only limited tissue volumes. Owing to this limitation, oxygenation is usually estimated using surrogate techniques, such as the monitoring of mixed venous oxygenation, heart rate, blood pressure, and oxygen saturation at the jugular bulb. However, these estimates can prove inaccurate as distal tissue oxygenation is not necessarily well represented by the more proximal measurements, and vice versa 6. MR perfusion imaging can be used to measure blood delivery to a tissue of interest, however, oxygen supply and demand can be independent of one another, e.g., revascularization of fibrotic tissue provides blood flow out of proportion to metabolic demand. Likewise, tissues with low levels of perfusion have an adequate oxygen supply while at rest, but an inadequate oxygen supply during periods of increased metabolic demand. Tissue perfusion alone, therefore, does not completely describe the underlying physiology of gas exchange 7 and thus direct, noninvasive measurement of blood oxygenation may be of interest in many clinical settings, as well as being of interest from a physiological perspective. Several techniques have been developed to quantify regional oxygenation using MRI. A promising method is the use of blood oxygen level dependent (BOLD) MRI 8, 9, where images that indicate impaired oxygen uptake can be generated, for example by cycling oxygen and carbogen levels 10. However, this technique provides only relative estimates of tissue oxygen partial pressure 11 because there are endogenous variations in magnetization relaxation parameters that can confound these measurements and thus make absolute oxygen concentration detection difficult. Moreover, BOLD signal response is governed by a mixture of dephasing and diffusion due to microscopic susceptibility gradients, and is therefore very much dependent upon the means of measurement, for example the choice of pulse sequence and field strength. Techniques that introduce exogenous tracers for MR oximetry, such as Overhauser‐enhanced MRI of unpaired radicals 12, 13 and 19F MRI 14, are promising for measurement of blood oxygenation; however, these tracers have yet to be applied in humans. In the lungs, the of inhaled hyperpolarized 3He gas in the airspaces 15, 16 has been used to quantify regional alveolar oxygen concentration, but regional ventilation‐perfusion mismatch and impaired gas transfer across the alveolar capillary interstitial barrier means this does not necessarily reflect the capillary blood oxygenation. Xenon has been in routine clinical use for many years as a tracer of blood perfusion 17, and the physiological effects of xenon gas administration are well known and characterized 18, 19. Hyperpolarized 129Xe MR has been shown in numerous studies to be a useful noninvasive probe of lung structure 20, 21, 22 and function 23, 24, 25, 26, 27, 28. Signal can be detected at low concentrations from this exogenous in vivo contrast agent, and owing to xenon's large, loosely bound electron cloud, 129Xe NMR is highly sensitive to the xenon chemical environment: 129Xe nuclei exhibit a marked change in resonance frequency when dissolved in different biological fluids and tissues 29, 30. Three distinct NMR peaks are observed in vivo when 129Xe gas is inhaled into the lungs. The largest peak originates from 129Xe gas in the alveolar airspaces and the two other peaks, centered approximately 200 ppm away from the gas peak, have been attributed to 129Xe dissolved in lung parenchymal tissue/blood plasma (TP) and in red blood cells (RBCs) 31, 32. Physiologically important information about gas exchange can be derived from the signal amplitudes and exchange kinetics of these distinct 129Xe resonances 20, 33. Furthermore, the 129Xe resonance frequency in RBCs was shown previously by Wolber et al. to be sensitive to blood oxygen saturation, sO2 34. Mechanisms underpinning the 129Xe chemical shift dependence on blood oxygenation are not yet fully understood, and the dependence is currently thought to be due to the conformational changes of hemoglobin as it binds and releases oxygen molecules 34. In the study reported here, spectra of hyperpolarized 129Xe dissolved in samples of human blood were obtained to validate the previous in vitro work conducted at B0 = 1.5 T by Wolber et al. 34. In so doing, we determine the relationship between the 129Xe‐RBC resonance frequency and blood oxygenation, over the full oxygenation range at the two clinically relevant field strengths of 1.5 T and 3 T. Using this relationship, measurements of RBC sO2 in vivo in healthy human lungs were then derived using whole lung NMR spectroscopy measurements of lung oxygen desaturation during breath hold apnea. A technique for the noninvasive dynamic detection of RBC sO2 in vivo using hyperpolarized 129Xe is hereby demonstrated.

METHODS

Hyperpolarized 129Xe Gas Preparation

For in vitro and in vivo studies, a gas mixture of 3 % isotopically enriched xenon (86 % 129Xe), 10 % nitrogen and 87 % helium was flowed through a glass cell (volume 500 cm3; temperature 373 K; total gas pressure 2 bars) on a home‐built 129Xe spin‐exchange optical pumping polarizer 35 at a flow rate of 300 sccm (standard cubic centimeters per minute). Upon exiting the cell, the hyperpolarized 129Xe was cryogenically separated in a liquid nitrogen‐cooled distilator and collected in its frozen state over a time of ∼20 min (xenon volume ∼ 200 mL) for in vitro samples and ∼60 min (xenon volume 600 mL) for in vivo samples.

Blood Sample Preparation and Analysis

Whole blood samples were withdrawn by a clinician from three self‐consenting healthy male volunteers (two Caucasian, ages 23 and 27; one Asian, age 35) by venipuncture and transferred into lithium heparin vacuum containers approximately 2–3 h before the start of the NMR experiments. All blood samples were allowed to equilibrate to a temperature of 20 ± 2 °C (the temperature at which the scanner room is maintained). Before conducting the NMR experiments, the xenon was first dissolved in the blood. To ensure effective mixing, the xenon and blood were passed through an exchange module 25, 36 (Superphobic MicroModule 0.5 X 1 G680 Contactor, Membrana, USA), which provided an exchange surface area of 100 cm2. The exchange module was also used to control the oxygenation of the blood samples before they were mixed with xenon. A clinical blood gas analyzer (Radiometer, ABL80, UK) was used to analyze each blood sample and determine the following physiological parameters: sO2 (fraction of hemoglobin molecules that are fully oxygenated), pO2 (partial pressure of O2 in whole blood), pCO2 (partial pressure of CO2 in whole blood), HCT (fraction of red blood cells within whole blood) and pH. Immediately after acquiring NMR spectra as described below, approximately 0.1 mL of blood was withdrawn directly from the NMR sample syringe and taken to the blood gas analyzer for analysis. Full experimental details of the xenon/oxygen dissolution method and RBC sO2 measurement technique have been described previously in a study reporting the relaxation behavior of 129Xe in blood 37.

In Vitro NMR Spectroscopy

A custom‐built, eight‐turn solenoid radiofrequency (RF) coil of 15 mm inner diameter was used for transmission/reception at the frequency of 129Xe dissolved in RBCs and plasma. The gas exchange membrane was positioned near the sensitive volume of the NMR coil to reduce the xenon‐blood transit time to the coil and, thus minimizing relaxation. To calibrate the excitation flip angle, a small sample of the hyperpolarized 129Xe‐blood mixture was placed within the active coil volume. Hard pulses of duration 500 μs were used to acquire spectra, and from these, the 129Xe‐RBC signal decrease was fitted to (cos α) ‐1, where α is the flip angle to be calibrated and n is the RF pulse number 37. The excitation flip angles used were calculated to be in the range 10–15°. Spectra were acquired on both 1.5 T (GE, HDx, USA) and 3 T (Philips, Achieva, Netherlands) MR scanners. At both B 0 field strengths, 20 pulse‐acquire measurements were made with 512 sample points, a receiver bandwidth of 2.5 kHz and a repetition time (TR) of 500 ms. Free induction decay data were imported into MATLAB (R2011b, MathWorks, USA) for spectral analysis. Zero‐order phase corrections (on the 129Xe‐RBC resonance), followed by first‐order phase corrections (to phase the 129Xe‐plasma resonance, using the 129Xe‐RBC resonance as the zero frequency point) were performed on the averaged raw data, and absorption spectra, Re[L], were fitted in the chemical shift (δ) domain to a linear combination of two Lorentzians where , are the amplitudes of the RBC and plasma 129Xe resonances; , are the maxima of the 129Xe‐RBC and 129Xe‐plasma resonances; and , are the full width half maxima of the two respective peaks. Figure 1a shows an example of a fit to a typical in vitro 1.5 T 129Xe‐blood spectrum.
Figure 1

a: Single‐shot 129Xe‐blood spectrum at 1.5 T. The measured absorption spectrum (blue line) was fitted to a linear combination of two Lorentzians (Equation (1), solid black line) to determine peak positions. b: Example 129Xe‐blood spectra acquired at 3 T. With increasing oxygenation, the peak associated with 129Xe dissolved in RBCs is seen to shift measurably toward a higher resonance frequency.

a: Single‐shot 129Xe‐blood spectrum at 1.5 T. The measured absorption spectrum (blue line) was fitted to a linear combination of two Lorentzians (Equation (1), solid black line) to determine peak positions. b: Example 129Xe‐blood spectra acquired at 3 T. With increasing oxygenation, the peak associated with 129Xe dissolved in RBCs is seen to shift measurably toward a higher resonance frequency.

In Vivo NMR Spectroscopy

Whole‐lung spectroscopy experiments were then performed at 3 T (Philips, Achieva, Netherlands) on two healthy male Caucasian volunteers (24 and 28 years old). All experiments were performed during breath hold apnea lasting 35–40 s. A 360 μs duration 90° hard pulse centered ∼200 ppm downfield from the gaseous 129Xe resonance was used for excitation of the 129Xe dissolved in RBCs (129Xe‐RBC) and parenchymal tissue/blood plasma (129Xe‐TP) using a flexible quadrature transmit/receive RF coil tuned to 35.35 MHz (Clinical MR Solutions, USA). See Figure 2 for relative signal intensities corresponding to 129Xe‐gas, 129Xe‐RBC, and 129Xe‐TP peaks in the lungs measured at 3 T.
Figure 2

Magnitude NMR spectrum of 129Xe acquired from the human lungs after a hard pulse excitation centered ∼220 ppm away from the gas peak (depicted here as a large peak outlined in blue). Spectral peaks associated with parenchymal tissue/blood plasma (TP) and RBCs are an order of magnitude smaller and have broader linewidths (shorter T 2*s) than the 129Xe‐gas peak. Inset: 129Xe‐gas resonance flip angle calibration for a hard pulse centered on the 129Xe‐dissolved resonance.

Magnitude NMR spectrum of 129Xe acquired from the human lungs after a hard pulse excitation centered ∼220 ppm away from the gas peak (depicted here as a large peak outlined in blue). Spectral peaks associated with parenchymal tissue/blood plasma (TP) and RBCs are an order of magnitude smaller and have broader linewidths (shorter T 2*s) than the 129Xe‐gas peak. Inset: 129Xe‐gas resonance flip angle calibration for a hard pulse centered on the 129Xe‐dissolved resonance. Two separate pulse‐acquire sequences with TRs of 100 ms (performed on the 28‐year‐old volunteer) and 800 ms (performed on both volunteers) were used, and the effective flip angle excitation on the 129Xe gas peak was determined to be ∼2.5° (see Figure 2) for a 90° excitation of the dissolved phase 129Xe. For the TR = 800 ms breath hold experiments, 2048 samples were acquired at a bandwidth of 3 kHz, corresponding to a spectral resolution of 1.46 Hz (0.04 ppm). To achieve a TR of 100 ms at 3 kHz bandwidth, the number of samples was decreased to 128, reducing the spectral resolution to ∼0.7 ppm. The spectra were phased and fitted to a double Lorentzian using the same method outlined in the previous section.

RESULTS

In Vitro Spectroscopy

The relationship between the chemical shift of 129Xe and sO2 of blood was calibrated in a controlled in vitro environment. The resonance frequency of 129Xe dissolved in plasma was used as a reference as it was found not to vary as a function of blood oxygenation in vitro. Increasing RBC sO2 caused an increase in the resonance frequency of 129Xe dissolved in RBCs. The RBC‐plasma peak separation increased from approximately 20.4 ppm, when the blood was in a completely deoxygenated state, to approximately 25.5 ppm when the blood was in a fully oxygenated state. This observed chemical shift versus sO2 behavior was consistent at B0 magnetic field strengths of both 1.5 T and 3 T. To quantify the change in RBC‐plasma peak separation, , as a function of sO2, the 129Xe‐RBC and 129Xe‐plasma peak locations, and , were determined by fitting the spectra to Equation (1). Blood gas analysis was performed immediately after acquiring the NMR spectra to quantify the RBC sO2. The extracted peak separations are plotted as a function of sO2 in Figure 3, where it can be observed that the chemical shift of 129Xe in RBCs appears to be nonlinearly dependent on the measured sO2, which is consistent with the previous observations of Wolber et al. 34. 1.5 T and 3 T data were fitted to a single empirical equation where, and are empirical constants and is the RBC‐plasma peak separation in fully deoxygenated blood (see Figure 3). The similarity in the measured 129Xe chemical shift values at 1.5 T and 3 T shown in Figure 3, therefore, suggest that the relationship between the 129Xe chemical shift and RBC sO2 is independent of the static magnetic field strength.
Figure 3

The 129Xe‐RBC chemical shift plotted against the measured blood oxygen saturation, sO2, with the 129Xe‐plasma peak as a 0 ppm reference peak. Data from the two field strengths are denoted by black open circles (1.5 T) and blue open squares (3 T). The black line is a fit to both the 1.5 T and 3 T data using Equation (2). The grey triangle represents blood equilibrated with carbon monoxide (simulating the fully oxygenated conformation of hemoglobin).

The 129Xe‐RBC chemical shift plotted against the measured blood oxygen saturation, sO2, with the 129Xe‐plasma peak as a 0 ppm reference peak. Data from the two field strengths are denoted by black open circles (1.5 T) and blue open squares (3 T). The black line is a fit to both the 1.5 T and 3 T data using Equation (2). The grey triangle represents blood equilibrated with carbon monoxide (simulating the fully oxygenated conformation of hemoglobin).

In Vivo Detection of Chemical Shift

To determine whether a similar shift in the resonance frequency of 129Xe in RBCs could be detected in vivo as a potential noninvasive probe for pulmonary blood oxygenation, a series of NMR spectra were acquired during breath hold apnea, which provides a simple model for blood oxygenation change. Figure 4 shows a waterfall plot of representative dissolved 129Xe spectra acquired as a function of time during one such experiment. The SNR of the spectrum at the beginning of the acquisition series was measured to be ∼50, dropping to ∼7 after 35 s of breath hold apnea. For these typical SNRs, it was possible to perform good Lorentzian fits on the data, enabling accurate peak assignment. The 129Xe resonance located at 0 ppm corresponds to the 129Xe‐TP resonance and the resonance located downfield is from 129Xe dissolved in RBCs. For all datasets, an initial rapid drop in the 129Xe‐RBC signal was observed, which we believe to be a result of RF‐induced depolarization of the postcapillary signal from the 129Xe in the pulmonary veins for TRs shorter than (TR = 100 ms), or of the order of (TR = 800 ms), the RBC capillary transit time of ∼750 ms 38.
Figure 4

Waterfall plot of a typical time series of in vivo 129Xe‐dissolved spectra. The resonance at 0 ppm is from 129Xe dissolved in parenchymal parenchymal tissue/blood plasma (TP) and the resonance downfield is from 129Xe dissolved in RBCs. Each spectrum was acquired using a flip angle of 90° and a TR of 800 ms. The decay in both compartments follows approximately the T 1 relaxation (due to the presence of oxygen in the lungs and RF excitation) of the 129Xe‐gas, the magnetization reservoir that acts to replenish the 129Xe‐dissolved signal between RF pulses.

Waterfall plot of a typical time series of in vivo 129Xe‐dissolved spectra. The resonance at 0 ppm is from 129Xe dissolved in parenchymal parenchymal tissue/blood plasma (TP) and the resonance downfield is from 129Xe dissolved in RBCs. Each spectrum was acquired using a flip angle of 90° and a TR of 800 ms. The decay in both compartments follows approximately the T 1 relaxation (due to the presence of oxygen in the lungs and RF excitation) of the 129Xe‐gas, the magnetization reservoir that acts to replenish the 129Xe‐dissolved signal between RF pulses. For TR = 800 ms, the 129Xe‐TP signal exhibited a monotonic decay over the breath hold time (Figure 5a). It was assumed that this signal decay follows the of the 129Xe gas (dominated by dipolar coupling of the nuclear spin with paramagnetic oxygen in the lungs), which acts as a longitudinal magnetization reservoir, replenishing the 129Xe‐dissolved magnetization in between RF pulses. With this assumption, a fit (corrected for 129Xe‐gas signal decay due to off‐resonance RF excitations of 2.5° on the gas resonance, which result from the side bands of the hard RF pulses used) was performed on the decaying 129Xe‐TP signal, resulting in an approximate 129Xe‐gas value of 18.8 s, which is in good agreement with previously measured 129Xe‐gas values of ∼ 20 s 39. Although the 129Xe‐RBC signal was observed to decay with the same overall rate as the 129Xe‐TP signal, it did not decay monotonically; instead, the signal was observed to modulate periodically over the breath hold time (see Figure 5a).
Figure 5

a: Decaying in vivo 129Xe‐dissolved signal in human lungs during breath‐hold apnea. The red circles and black squares represent 129Xe in RBCs and parenchymal tissue/blood plasma (TP), respectively. While the 129Xe‐TP signal decays monotonically, the 129Xe‐RBC signal does not. The black line is an exponential fit to the decaying 129Xe‐TP signal, from which a 129Xe‐gas was estimated. b: 129Xe‐RBC signal divided by the fitted exponential in (a), expressed as a fractional change (Δ) in signal intensity.

a: Decaying in vivo 129Xe‐dissolved signal in human lungs during breath‐hold apnea. The red circles and black squares represent 129Xe in RBCs and parenchymal tissue/blood plasma (TP), respectively. While the 129Xe‐TP signal decays monotonically, the 129Xe‐RBC signal does not. The black line is an exponential fit to the decaying 129Xe‐TP signal, from which a 129Xe‐gas was estimated. b: 129Xe‐RBC signal divided by the fitted exponential in (a), expressed as a fractional change (Δ) in signal intensity. To view this oscillatory decay behavior more clearly, the 129Xe‐RBC signal was normalized to the decay of the 129Xe‐gas polarization reservoir (129Xe‐RBC data were divided pointwise by the fitted curve – see Figure 5b). For both volunteers, the 129Xe‐RBC peak‐to‐peak signal interval (i.e. modulation period) was measured to be 4–8 s (0.125–0.25 Hz). Whereas the 129Xe‐TP resonance was observed to remain fixed in position over the 35 s breath hold, the 129Xe‐RBC resonance chemical shift was observed to decrease by approximately 1 ppm. The first observation of in vivo 129Xe‐RBC resonance shifts with lung oxygenation was first reported in our preliminary work 40, and these findings have been recently confirmed by Kaushik et al. 41, who observed a decrease in the 129Xe‐RBC resonance frequency in patients with idiopathic pulmonary fibrosis relative to healthy normals. Here, the 129Xe‐RBC chemical shift exhibited a periodic modulation at the same frequency as the 129Xe‐RBC signal oscillation, with a 180° phase difference (Figs. 6a, 8). Equation (2) was used to determine sO2 values from the measured in vivo 129Xe‐RBC chemical shift values. The sO2 in both volunteers at the start of the breath hold was measured to be ∼0.87, dropping to ∼0.80 at the end of the 35 s breath hold (Figure 6b).
Figure 6

a: 129Xe‐RBC chemical shift in human lungs in vivo over the course of a breath hold, where a clear periodic modulation is observed. b: Calculated blood oxygenation over the breath hold, derived from the measured 129Xe‐RBC chemical shifts using Equation (2).

Figure 8

In vivo lung blood oxygenation and 129Xe‐RBC signal changes over breath hold apnea measured from two healthy volunteers, (a) and (b) (28 and 24 years old, respectively). The blood oxygenation and 129Xe‐RBC signal oscillate at the same frequency where the blood oxygenation maxima/minima coincide with 129Xe‐RBC signal minima/maxima (i.e. a phase difference of 180°).

a: 129Xe‐RBC chemical shift in human lungs in vivo over the course of a breath hold, where a clear periodic modulation is observed. b: Calculated blood oxygenation over the breath hold, derived from the measured 129Xe‐RBC chemical shifts using Equation (2). In these calculations, it was assumed that the temperature difference in vitro (20 °C) and in vivo (37 °C) has a negligible effect on the 129Xe‐RBC and 129Xe‐TP resonances, i.e. the calibration curve in Figure 3 is valid for converting the in vivo 129Xe‐RBC chemical shift to pulmonary sO2. To test the validity of this assumption, NMR spectra of 129Xe dissolved in plasma were acquired at 20 °C and 37 °C with a 129Xe gas compartment as a 0 ppm reference. No differences in the 129Xe‐gas and 129Xe‐plasma resonances were observed when the sample was heated from 20 °C to 37 °C. Albert et al. 42 previously measured a chemical shift difference of ∼20 ppm between the 129Xe‐RBC and 129Xe‐plasma resonances in deoxygenated blood at a temperature of 8 °C, which is in good agreement with the chemical difference of 20.4 ppm we have observed at 20 °C. We therefore assume the 129Xe‐RBC resonance is independent of temperature over the range 20 °C to 37 °C. For TR = 100 ms, both the 129Xe‐TP and 129Xe‐RBC signals exhibited oscillations with an approximately constant peak‐to‐peak signal interval (modulation period) of ∼1 s over the breath hold duration.

DISCUSSION

The observation of a nonlinear dependence of 129Xe‐RBC chemical shift on sO2 has been reported in previous work by Wolber et al. 34, where it was concluded that bulk magnetic susceptibility differences between oxyhemoglobin (diamagnetic) and deoxyhemoglobin (paramagnetic) are not responsible for the ∼5 ppm 129Xe‐RBC chemical shift difference between oxygenated and deoxygenated blood. Instead, the authors hypothesized that the observed nonlinear relationship between blood oxygenation and chemical shift is the result of an oxygen‐dependent hemoglobin affinity for xenon. To date, a total of 12 xenon binding sites have been located in deoxyhemoglobin using X‐ray crystallography 43. To our knowledge, the binding sites of xenon in oxyhemoglobin have not been reported, making a quantitative description of the chemical shift mechanisms responsible for the observed nonlinear change in chemical shift with blood of oxygenation difficult at this time. Nevertheless, herein, we draw on the insights of Wolber et al. 34 to further understand the mechanisms governing the observed nonlinear relationship between the 129Xe‐RBC chemical shift and blood oxygenation. The resonance frequency of 129Xe in a solvent solution is determined by the local magnetic field experienced at the nucleus, which is mediated by the screening (or shielding) constant, σ: where is the observed resonance frequency, is the gyromagnetic ratio, is the applied static magnetic field and is the effective field at the nucleus. Following the pioneering work of Buckingham et al. 44, it is known that the screening constant, , of a nucleus can be expressed as the sum of the screening constant of the individual nucleus, , and a term arising due to the presence of the solvent medium, , thus where is a contribution from molecular anisotropy effects, is the polar effect caused by an electric field, is due to the van der Waals forces between the solute and solvent and indicates the shielding arising from bulk magnetic susceptibility effects within the solvent, which we neglect as a significant contributor to 129Xe chemical shift changes with blood oxygenation from the conclusions drawn by Wolber et al. 34. For 129Xe dissolved in solution at 20 °C and at body temperature (37 °C), the anisotropic and electric field terms are zero 45, leaving only the van der Waals shielding term. Stephen 46 has demonstrated that the van der Waals deshielding experienced by a nucleus within a solvent can be expressed as , where is the mean square electric field brought about by fluctuations among electrons located on the neighboring solvent molecules and B is the “shielding hyperpolarizability” 47, which is significant for 129Xe, whose nucleus is surrounded by a large, easily‐deformed electron cloud. As a result of this high shielding hyperpolarizabilty, the chemical shift of dissolved 129Xe in a solvent is very sensitive to small differences in the dispersion fields acting within liquid solvents. The most commonly used approach to correlate solvent‐induced 129Xe chemical shifts with is to use a continuum model to describe the solvent 48, 49. Specifically, is proportional to the square of the Bayliss‐McRae function, 49, i.e., , where n is the index of refraction of the solvent. The refractive indices of oxyhemoglobin and deoxyhemoglobin have been recently measured by Zhernovaya et al. 50, wherein no significant difference between the refractive index of deoxygenated and oxygenated hemoglobin (within the visible range of the spectrum) was reported. We therefore conclude that the observed 129Xe‐RBC chemical shift change with blood oxygenation cannot be predicted using whole blood refractive index measurements. Experiments using Mössbauer spectroscopy 51 suggest that the electron cloud of hemoglobin is drawn toward the highly electronegative oxygen molecule in oxyhemoglobin, but is more evenly distributed in deoxyhemoglobin. Similarly, as 129Xe forms transient van der Waals bonds with hemoglobin, the net electron cloud of 129Xe is likely to be drawn to the more electronegative O2 molecule in oxyhemoglobin. This would act to increase the deshielding of the 129Xe nucleus, thereby reducing , resulting in an increased 129Xe‐RBC resonance frequency, which is in agreement with the observed data. In addition to changes in the electronegativity of the hemoglobin molecules with blood oxygenation, the xenon‐hemoglobin binding site locations may change as the hemoglobin makes transitions between oxy‐ and deoxy‐conformations. As the extent of the shielding constant is strongly dependent on the separation between a nucleus and the molecules giving rise to fluctuating electric fields 47, changes in position would greatly alter the magnitude of the mean square field, , experienced by the 129Xe nucleus within the hemoglobin. Each RBC contains a large number of individual hemoglobin molecules, and the fraction of hemoglobin molecules in the oxy‐ and deoxy‐conformations has been measured previously in horse hemoglobin to vary smoothly as a function of blood oxygenation 52. The intracellular environment experienced by 129Xe nuclei would thus be expected to vary smoothly as a function of blood oxygenation, which is consistent with the observation of a smooth nonlinear change in the 129Xe‐RBC resonance with blood oxygenation. Finally, to help determine whether the underlying mechanisms driving the change in 129Xe relaxation rate and 129Xe‐RBC chemical shift with sO2 are related, a correlation plot of the variation of the two NMR parameters was generated, as shown in Figure 7. The 129Xe‐RBC relaxation rate data are taken from our previous study 37 in which the relationship between 129Xe‐RBC relaxation rate and sO2 was determined. The plot reveals that changes in 129Xe‐RBC relaxation rate and 129Xe‐RBC chemical shift are well correlated, with a coefficient of determination of R 2 = 0.83. This presents strong empirical evidence that the underlying physical mechanism driving these observed changes in chemical shift and relaxation rate is the same. As the chemical shift and relaxation rate of 129Xe in solvents is strongly dependent on intermolecular separations, we therefore conclude it is likely that oxygen‐modulated xenon binding is largely responsible for the observed 129Xe‐RBC chemical shift and relaxation rate sO2 dependencies.
Figure 7

Correlation of 129Xe‐RBC relaxation rate and 129Xe‐RBC chemical shift in whole blood samples over the full (0.06–1.00) blood oxygenation range.

Correlation of 129Xe‐RBC relaxation rate and 129Xe‐RBC chemical shift in whole blood samples over the full (0.06–1.00) blood oxygenation range.

In Vivo Spectroscopy

As shown in Figures 8a and b, for TR = 800 ms, the sO2 values calculated from the 129Xe‐RBC chemical shift were shown to oscillate over the breath hold at the same frequency as the 129Xe‐RBC signal amplitude modulation, but with a 180° phase difference; the sO2 maxima were observed to coincide with the 129Xe‐RBC signal minima, suggestive of a link between pulmonary oxygenation and 129Xe‐RBC signal changes. The calculated sO2 of ∼0.87 for both volunteers at the beginning of the breath hold suggests that the observed 129Xe‐RBC signal comprises 129Xe dissolved in blood containing RBCs with mixed sO2 values; otherwise it would be expected that the calculated sO2 would equal either 1.00 for fully oxygenated blood or ∼0.75 for deoxygenated blood. Indeed, for TR values of 100–800 ms, the observed 129Xe‐RBC signal should be constituted primarily by 129Xe nuclei dissolved in blood circulating in the alveolar capillary bed, which contains blood with a range of sO2 values. Signal contribution from 129Xe dissolved in blood circulating in the pulmonary arteries (precapillary blood) is assumed to be negligible as a result of 129Xe polarization losses incurred during 129Xe transit in the systemic circulation. Signal from 129Xe in the pulmonary veins is also considered to be negligible, as the postcapillary 129Xe signal is destroyed by 90° RF pulses for TR values of 100–800 ms, which are of the order of the RBC capillary transit time of 750 ms. In vivo lung blood oxygenation and 129Xe‐RBC signal changes over breath hold apnea measured from two healthy volunteers, (a) and (b) (28 and 24 years old, respectively). The blood oxygenation and 129Xe‐RBC signal oscillate at the same frequency where the blood oxygenation maxima/minima coincide with 129Xe‐RBC signal minima/maxima (i.e. a phase difference of 180°). A first‐order estimate of the expected average sO2 of RBCs which contribute to the observed 129Xe‐RBC signal for TR = 800 ms can be derived using the following assumption: the average RBC oxygenation in the capillaries sO2c = [0.75 (deoxygenated) + 1.00 (oxygenated)] / 2 = 0.88. This agrees well with the sO2 value of 0.87 calculated from the ∼22 ppm chemical shift observed at the start of breath hold apnea in both healthy volunteers for TR = 800 ms. After 35 s of breath hold apnea, a decrease in the observed of 7–10 % was calculated for both volunteers. During breath hold the oxygen partial pressure, pO2, in the lungs will decrease over time. Measurements of changes in oxygen partial pressure as a function of breath hold have been performed in both animal and human lungs using hyperpolarized 3He MR 16, 53, 54. It was shown in humans that over short breath holds (< 40 s), the decrease in pO2 can be approximated by a linear relationship 15, 16, 53 where R is the rate of oxygen extraction by perfusion and is the initial pO2. Previous studies involving pO2 mapping with 3He in healthy volunteers 16, 53, 55 reported R to decrease with decreasing . This may be a result of the lower baseline pO2 reducing the alveolar‐capillary pO2 gradient, and, therefore, decreasing the rate of diffusion of oxygen from the alveoli into the capillaries. It is worth noting that over long breath holds and/or large R values, an exponential model of oxygen depletion should be used instead of Equation (8), which for small t is the first term in the Taylor expansion of an exponential function 54. Assuming a functional residual capacity of 3 L for the healthy male volunteers in this study and a resting pO2 of 140 mbar 38, the pO2 drop upon inhalation of 1 L of anoxic gas (Xe/N2) can be estimated by scaling the pO2 with the increase in lung volume to 4 L, i.e. mbar. The R value for = 105 mbar has been reported to be R = 0.7 mbar/s 55. Inserting these values into Equation (8), the pO2 is estimated to drop to pO2 = 81 mbar at the end of 35 s of breath hold apnea, which corresponds to a saturation sO2 value of 0.89 from the standard oxygen‐hemoglobin dissociation curve 56, 57. Using this value, the average alveolar capillary bed oxygenation can be calculated as sO2c = [0.75 (deoxygenated) + 0.89 (oxygenated)] / 2 = 0.82, which is in reasonable agreement with the sO2 estimates (measured from the 129Xe chemical shift) of approximately 0.80 for both volunteers after ∼35 s of breath hold apnea. For TR = 100 ms, both the 129Xe‐RBC and 129Xe‐TP signals were observed to oscillate at a frequency close to the cardiac pulsation frequency (Figure 9), suggesting that the lower frequency signal oscillation observed for TR = 800 ms (Figure 8) is actually an alias of the higher frequency oscillation observed for TR = 100 ms. The gray line in Figure 9b shows artificial signal sampling at a rate of 800 ms−1 to illustrate this effect. 129Xe‐RBC and 129Xe‐TP signal oscillations at similar cardiac pulsation frequencies were first observed by Venkatesh et al. 58 and have been more recently observed by Ruppert et al. 59, where the signal oscillations were attributed to changes in blood flux into the capillaries within the cardiac cycle.
Figure 9

a: In vivo 129Xe‐RBC signal in the lungs as a function of breathhold time for a TR of 100 ms, fitted with an exponential function. b: In vivo 129Xe‐RBC and 129Xe‐TP signal changes normalized to the fitted exponential in (a). The gray line illustrates the effect of sampling the observed 129Xe‐RBC and 129Xe‐TP signal oscillations at a rate of 800 ms−1.

a: In vivo 129Xe‐RBC signal in the lungs as a function of breathhold time for a TR of 100 ms, fitted with an exponential function. b: In vivo 129Xe‐RBC and 129Xe‐TP signal changes normalized to the fitted exponential in (a). The gray line illustrates the effect of sampling the observed 129Xe‐RBC and 129Xe‐TP signal oscillations at a rate of 800 ms−1. For the faster‐sampled experiment at TR = 100 ms, the spectral resolution was limited to 0.7 ppm, which was insufficient to spectrally discriminate changes in the 129Xe‐RBC chemical shift over the breath hold. It is possible that the observed sO2 for TR = 100 ms would be lower than that observed for TR = 800 ms; for short TRs, the RBCs have less time to travel through the capillaries into the pulmonary veins in between RF pulses (i.e. it is possible that the observable pulmonary sO2 varies as a function of the TR used). Cardiac‐gated acquisitions may allow the probing of 129Xe‐RBC chemical shifts (sO2) at specific time points in the cardiac cycle, opening up the possibility of using 129Xe NMR to quantify temporal blood oxygenation changes in the cardiopulmonary vascular circuit. With the assumption that the 129Xe‐TP signal modulation arises from blood plasma flux changes within the cardiac cycle, it is possible to compare the peak‐to‐peak 129Xe‐RBC signal, amplitude, SA, with the 129Xe‐TP signal amplitude, SB, to estimate the relative RBC and plasma concentrations in the blood circulating through the capillaries. Thus, by taking the average of the first five SA and SB values after steady‐state was reached, and , respectively, the HCT in the capillaries may be estimated from where and = 0.27, = 0.094 are the solubilities of xenon in RBCs and plasma at 37 °C 60. Inserting these values into Equation (9) gives HCTc = 0.44, in good agreement with the Fåhræus effect which predicts HCT < 0.50 61 for blood flowing in narrow vessels such as the pulmonary capillaries. This is potentially of interest clinically; however, further work is required to validate this technique for measurement of HCT in the pulmonary capillaries. This dissolved 129Xe spectroscopy oximetry technique may also have applications outside of the lungs. For example, Mazzanti et al. 62 have recently shown that the signal of 129Xe dissolved in the rat brain can be modulated in a manner responsive to stimuli, suggestive that there is a significant contribution to the measured 129Xe signal from blood flow/perfusion. Moreover, dissolved 129Xe spectra from the human brain have been successfully acquired 63, suggesting that 129Xe can be detected in organs quite distal from the point of uptake in the lungs. Finally, this work has implications for Dixon‐based dissolved 129Xe imaging methods 64, 65, which rely upon a fixed chemical shift difference between the target spectroscopic compartments; the frequency difference between compartments is encoded as a phase shift in a given echo time and the different echo times need to be fixed in value. Therefore, drift in the 129Xe‐RBC peak position would affect the intensity of the 129Xe‐RBC phase image.

CONCLUSIONS

In this study, the feasibility of using hyperpolarized 129Xe as an exogenous NMR probe of pulmonary blood oxygenation in humans has been explored. A nonlinear relationship between the measured sO2 values and the NMR resonance frequency of 129Xe dissolved in RBCs has been observed in vitro from blood samples at 1.5 T and 3 T. This relationship was evaluated over the entire range of possible blood oxygenation values and appears to be independent of magnetic field strength. Furthermore, this relation has been used to derive lung blood sO2 values by means of in vivo dissolved 129Xe whole‐lung spectroscopy experiments conducted during apnea on a 3 T whole body system. To date, we are not aware of any other means of noninvasively measuring pulmonary blood oxygenation. The common modulation frequency of blood oxygenation and 129Xe‐RBC signal change during breath hold is interesting and further work with cardiac‐gated hyperpolarized 129Xe NMR is underway to help understand this newly observed phenomenon. Lastly, the HCT in the pulmonary capillaries has been estimated from 129Xe spectroscopic data. Further work is underway to validate hyperpolarized 129Xe NMR as a noninvasive technique for quantification of HCT in the pulmonary capillaries.
  52 in total

1.  T(1) of (129)Xe in blood and the role of oxygenation.

Authors:  M S Albert; D F Kacher; D Balamore; A K Venkatesh; F A Jolesz
Journal:  J Magn Reson       Date:  1999-09       Impact factor: 2.229

2.  The hibernating myocardium.

Authors:  S H Rahimtoola
Journal:  Am Heart J       Date:  1989-01       Impact factor: 4.749

3.  Tumor oximetry: demonstration of an enhanced dynamic mapping procedure using fluorine-19 echo planar magnetic resonance imaging in the Dunning prostate R3327-AT1 rat tumor.

Authors:  S Hunjan; D Zhao; A Constantinescu; E W Hahn; P P Antich; R P Mason
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-03-15       Impact factor: 7.038

4.  Chronic obstructive pulmonary disease: safety and tolerability of hyperpolarized 129Xe MR imaging in healthy volunteers and patients.

Authors:  Bastiaan Driehuys; Santiago Martinez-Jimenez; Zackary I Cleveland; Gregory M Metz; Denise M Beaver; John C Nouls; S Sivaram Kaushik; Rafael Firszt; Christine Willis; Kevin T Kelly; Jan Wolber; Monica Kraft; H Page McAdams
Journal:  Radiology       Date:  2011-11-04       Impact factor: 11.105

5.  Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by (3)He MRI.

Authors:  A J Deninger; B Eberle; M Ebert; T Grossmann; W Heil; H Kauczor; L Lauer; K Markstaller; E Otten; J Schmiedeskamp; W Schreiber; R Surkau; M Thelen; N Weiler
Journal:  J Magn Reson       Date:  1999-12       Impact factor: 2.229

Review 6.  The neutrophil in chronic obstructive pulmonary disease.

Authors:  Kim Hoenderdos; Alison Condliffe
Journal:  Am J Respir Cell Mol Biol       Date:  2013-05       Impact factor: 6.914

7.  Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon-129 MRI.

Authors:  Kun Qing; Kai Ruppert; Yun Jiang; Jaime F Mata; G Wilson Miller; Y Michael Shim; Chengbo Wang; Iulian C Ruset; F William Hersman; Talissa A Altes; John P Mugler
Journal:  J Magn Reson Imaging       Date:  2013-05-16       Impact factor: 4.813

8.  Human pulmonary imaging and spectroscopy with hyperpolarized 129Xe at 0.2T.

Authors:  Samuel Patz; Iga Muradian; Mirko I Hrovat; Iulian C Ruset; George Topulos; Silviu D Covrig; Eric Frederick; Hiroto Hatabu; F W Hersman; James P Butler
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

9.  Single-breath clinical imaging of hyperpolarized (129)Xe in the airspaces, barrier, and red blood cells using an interleaved 3D radial 1-point Dixon acquisition.

Authors:  S Sivaram Kaushik; Scott H Robertson; Matthew S Freeman; Mu He; Kevin T Kelly; Justus E Roos; Craig R Rackley; W Michael Foster; H Page McAdams; Bastiaan Driehuys
Journal:  Magn Reson Med       Date:  2015-05-18       Impact factor: 4.668

10.  Distribution of hyperpolarized xenon in the brain following sensory stimulation: preliminary MRI findings.

Authors:  Mary L Mazzanti; Ronn P Walvick; Xin Zhou; Yanping Sun; Niral Shah; Joey Mansour; Jessica Gereige; Mitchell S Albert
Journal:  PLoS One       Date:  2011-07-15       Impact factor: 3.240

View more
  19 in total

1.  Transverse relaxation rates of pulmonary dissolved-phase Hyperpolarized 129 Xe as a biomarker of lung injury in idiopathic pulmonary fibrosis.

Authors:  Jeff Kammerman; Andrew D Hahn; Robert V Cadman; Annelise Malkus; David Mummy; Sean B Fain
Journal:  Magn Reson Med       Date:  2020-03-11       Impact factor: 4.668

2.  Uncovering a third dissolved-phase 129 Xe resonance in the human lung: Quantifying spectroscopic features in healthy subjects and patients with idiopathic pulmonary fibrosis.

Authors:  Scott H Robertson; Rohan S Virgincar; Elianna A Bier; Mu He; Geoffrey M Schrank; Rose Marie Smigla; Craig Rackley; H Page McAdams; Bastiaan Driehuys
Journal:  Magn Reson Med       Date:  2016-11-08       Impact factor: 4.668

3.  Theoretical study of the NMR chemical shift of Xe in supercritical condition.

Authors:  Evanildo G Lacerda; Stephan P A Sauer; Kurt V Mikkelsen; Kaline Coutinho; Sylvio Canuto
Journal:  J Mol Model       Date:  2018-02-20       Impact factor: 1.810

4.  Mapping cardiopulmonary dynamics within the microvasculature of the lungs using dissolved 129Xe MRI.

Authors:  Peter J Niedbalski; Elianna A Bier; Ziyi Wang; Matthew M Willmering; Bastiaan Driehuys; Zackary I Cleveland
Journal:  J Appl Physiol (1985)       Date:  2020-06-18

5.  Investigating biases in the measurement of apparent alveolar septal wall thickness with hyperpolarized 129Xe MRI.

Authors:  Kai Ruppert; Faraz Amzajerdian; Yi Xin; Hooman Hamedani; Luis Loza; Tahmina Achekzai; Ian F Duncan; Harrilla Profka; Yiwen Qian; Mehrdad Pourfathi; Stephen Kadlecek; Rahim R Rizi
Journal:  Magn Reson Med       Date:  2020-06-18       Impact factor: 4.668

6.  Rapid assessment of pulmonary gas transport with hyperpolarized 129Xe MRI using a 3D radial double golden-means acquisition with variable flip angles.

Authors:  Kai Ruppert; Faraz Amzajerdian; Hooman Hamedani; Yi Xin; Luis Loza; Tahmina Achekzai; Ian F Duncan; Harrilla Profka; Sarmad Siddiqui; Mehrdad Pourfathi; Maurizio F Cereda; Stephen Kadlecek; Rahim R Rizi
Journal:  Magn Reson Med       Date:  2018-04-22       Impact factor: 4.668

7.  A portable ventilator with integrated physiologic monitoring for hyperpolarized 129Xe MRI in rodents.

Authors:  Rohan S Virgincar; Jerry Dahlke; Scott H Robertson; Nathann Morand; Yi Qi; Simone Degan; Bastiaan Driehuys; John C Nouls
Journal:  J Magn Reson       Date:  2018-07-23       Impact factor: 2.229

8.  Simple and robust referencing system enables identification of dissolved-phase xenon spectral frequencies.

Authors:  Michael A Antonacci; Le Zhang; Alex Burant; Drew McCallister; Rosa T Branca
Journal:  Magn Reson Med       Date:  2017-12-19       Impact factor: 4.668

9.  A protocol for quantifying cardiogenic oscillations in dynamic 129 Xe gas exchange spectroscopy: The effects of idiopathic pulmonary fibrosis.

Authors:  Elianna A Bier; Scott H Robertson; Geoffry M Schrank; Craig Rackley; Joseph G Mammarappallil; Sudarshan Rajagopal; H Page McAdams; Bastiaan Driehuys
Journal:  NMR Biomed       Date:  2018-11-20       Impact factor: 4.044

10.  Assessment of flip angle-TR equivalence for standardized dissolved-phase imaging of the lung with hyperpolarized 129Xe MRI.

Authors:  Kai Ruppert; Faraz Amzajerdian; Hooman Hamedani; Yi Xin; Luis Loza; Tahmina Achekzai; Ian F Duncan; Harrilla Profka; Sarmad Siddiqui; Mehrdad Pourfathi; Federico Sertic; Maurizio F Cereda; Stephen Kadlecek; Rahim R Rizi
Journal:  Magn Reson Med       Date:  2018-10-22       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.