Literature DB >> 27041789

Spectral X-Ray Diffraction using a 6 Megapixel Photon Counting Array Detector.

Ryan D Muir1, Nicholas R Pogranichniy1, J Lewis Muir2, Shane Z Sullivan1, Kevin P Battaile2, Anne M Mulichak2, Scott J Toth1, Lisa J Keefe1, Garth J Simpson1.   

Abstract

Pixel-array array detectors allow single-photon counting to be performed on a massively parallel scale, with several million counting circuits and detectors in the array. Because the number of photoelectrons produced at the detector surface depends on the photon energy, these detectors offer the possibility of spectral imaging. In this work, a statistical model of the instrument response is used to calibrate the detector on a per-pixel basis. In turn, the calibrated sensor was used to perform separation of dual-energy diffraction measurements into two monochromatic images. Targeting applications include multi-wavelength diffraction to aid in protein structure determination and X-ray diffraction imaging.

Entities:  

Year:  2015        PMID: 27041789      PMCID: PMC4815032          DOI: 10.1117/12.2079548

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  10 in total

1.  A probability representation for phase information from multiwavelength anomalous dispersion.

Authors:  A Pähler; J L Smith; W A Hendrickson
Journal:  Acta Crystallogr A       Date:  1990-07-01       Impact factor: 2.290

2.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors.

Authors:  E Roessl; R Proksa
Journal:  Phys Med Biol       Date:  2007-07-17       Impact factor: 3.609

3.  [Evaluation of Laue diffraction patterns.

Authors:  I J Clifton; E M Duke; S Wakatsuki; Z Ren
Journal:  Methods Enzymol       Date:  1997       Impact factor: 1.600

4.  Photolysis of the carbon monoxide complex of myoglobin: nanosecond time-resolved crystallography.

Authors:  V Srajer; T Teng; T Ursby; C Pradervand; Z Ren; S Adachi; W Schildkamp; D Bourgeois; M Wulff; K Moffat
Journal:  Science       Date:  1996-12-06       Impact factor: 47.728

5.  Linear fitting of multi-threshold counting data with a pixel-array detector for spectral X-ray imaging.

Authors:  Ryan D Muir; Nicholas R Pogranichney; J Lewis Muir; Shane Z Sullivan; Kevin P Battaile; Anne M Mulichak; Scott J Toth; Lisa J Keefe; Garth J Simpson
Journal:  J Synchrotron Radiat       Date:  2014-08-15       Impact factor: 2.616

Review 6.  Radiation damage to protein specimens from electron beam imaging and diffraction: a mini-review of anti-damage approaches, with special reference to synchrotron X-ray crystallography.

Authors:  William H Massover
Journal:  J Synchrotron Radiat       Date:  2006-12-15       Impact factor: 2.616

7.  Time-resolved X-ray crystallographic study of the conformational change in Ha-Ras p21 protein on GTP hydrolysis.

Authors:  I Schlichting; S C Almo; G Rapp; K Wilson; K Petratos; A Lentfer; A Wittinghofer; W Kabsch; E F Pai; G A Petsko
Journal:  Nature       Date:  1990-05-24       Impact factor: 49.962

8.  Phase determination by multiple-wavelength x-ray diffraction: crystal structure of a basic "blue" copper protein from cucumbers.

Authors:  J M Guss; E A Merritt; R P Phizackerley; B Hedman; M Murata; K O Hodgson; H C Freeman
Journal:  Science       Date:  1988-08-12       Impact factor: 47.728

9.  Dual-energy mammography: a detector analysis.

Authors:  J M Boone; G S Shaber; M Tecotzky
Journal:  Med Phys       Date:  1990 Jul-Aug       Impact factor: 4.071

Review 10.  A beginner's guide to radiation damage.

Authors:  James M Holton
Journal:  J Synchrotron Radiat       Date:  2009-02-25       Impact factor: 2.616

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.