BACKGROUND: Catheter malfunction, including thrombosis, is associated with reduced dialysis adequacy, as well as an increased risk of catheter-related bacteraemia and mortality. The role of anticoagulants in the prevention of catheter malfunction remains uncertain.
OBJECTIVES: This review aimed to compare the prophylactic effect of different anticoagulant agents, preparations, doses and administration on the incidence of central venous haemodialysis catheter-related malfunction and sepsis in patients with end-stage kidney disease (ESKD). SEARCH
METHODS: We searched the Cochrane Renal Group's Specialised Register to 7 January 2016 through contact with the Trials' Search Co-ordinator using search terms relevant to this review. SELECTION CRITERIA: We included all randomised controlled trials (RCT) assessing anticoagulants compared with conventional care for the prevention of catheter malfunction in adult patients receiving haemodialysis for ESKD. DATA COLLECTION AND ANALYSIS: The primary outcome was catheter malfunction defined as a catheter blood flow of 200 mL/min or less, or as defined by study authors. Secondary outcomes were catheter-related bacteraemia, all-cause mortality and bleeding events. Relative risks (RR) with 95% confidence intervals (CI) for individual studies were pooled using random effects models within treatment classes. Analyses were conducted by class, with subgroup analyses performed of individual agents within classes. MAIN
RESULTS: We included 27 studies (3003 participants) that were followed up for a median of six months. Study interventions included alternative anticoagulant locking solutions (19 studies, 2216 patients), systemic agents (6 studies, 664 patients) and low or no dose heparin (2 studies, 123 patients). The most common comparison treatment was a locking solution of heparin 5000 IU/mL, used in 17 studies. No significant effect on catheter malfunction was observed for alternative anticoagulant locking solutions (RR 0.96, 95% CI 0.74 to 1.26), systemic agents (RR 0.59, 95% CI 0.28 to 1.23), or low or no dose heparin (RR 0.90, 95% CI 0.10 to 8.31). A significant reduction on incidence of catheter-related bacteraemia was observed for alternative anticoagulant locking solutions (RR 0.46, 95% CI 0.32 to 0.66) but not systemic agents (RR 2.41, 95% CI 0.89 to 6.55), and could not be assessed in reports of low or no dose heparin studies. No significant effect on all-cause mortality was observed for alternative anticoagulant locking solutions (RR 0.88, 95% CI 0.54 to 1.43) or systemic agents (RR 0.78, 95% CI 0.37 to 1.65), and was not reported in studies of low or no dose heparin. Bleeding events were only reported in eight studies, including only 2/5 studies of systemic warfarin, with no clear effect demonstrated (RR 1.43, 95% CI 0.86 to 2.39). For individual agents, recombinant tissue plasminogen (rt-PA) was the only locking solution shown to reduce catheter malfunction (RR 0.58, 95% CI 0.37 to 0.91) based on the results of a single study. No significant on catheter malfunction was observed for other individual classes of alternative anticoagulant locking solutions (citrate: RR 1.14, 95% CI 0.76 to 1.69; antibiotic: RR 1.48, 95% CI 0.79 to 2.77; ethanol: RR 0.88, 95% CI 0.21 to 3.67). On the other hand, all individual classes of alternative anticoagulant locking solutions, except ethanol, reduced catheter-related bacteraemia (citrate: RR 0.49, 95% CI 0.36 to 0.68; antibiotic: RR 0.27, 95% CI 0.11 to 0.70; rt-PA: RR 0.35, 95% CI 0.13 to 0.93; ethanol: RR 0.33, 95% CI 0.03 to 4.05). No significant effect on all-cause mortality was observed for any individual agent within the class of alternative locking solutions. Studies were mainly of low quality and underpowered with an average participant number of 75 and study duration of six months. The interpretation of the study evidence was further limited by the variation in tested interventions and outcome reporting. AUTHORS'
CONCLUSIONS: The relative net benefit of anticoagulant therapies for prevention of catheter malfunction remains uncertain. Multiple agents appear to reduce catheter-related bacteraemia although the lack of clear assessment of harms and the limitations of study quality mean these results should be interpreted with caution. Methodological approaches can be used to avoid methods of reporting unduly affecting on the results of meta-analyses incorporating studies employed mixed reporting methods. Further high quality randomised studies, including safety outcomes, are needed.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27039404      PMCID: PMC7097886          DOI: 10.1002/14651858.CD009631.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  69 in total

1.  Low-dose warfarin fails to prolong survival of dual lumen venous dialysis catheters.

Authors:  J P Traynor; D Walbaum; Y M Woo; P Teenan; J G Fox; R A Mactier
Journal:  Nephrol Dial Transplant       Date:  2001-03       Impact factor: 5.992

2.  A prospective, randomized, double-blind crossover study on the use of 5% citrate lock versus 10% citrate lock in permanent hemodialysis catheters.

Authors:  Gert Meeus; Dirk R J Kuypers; Kathleen Claes; Pieter Evenepoel; Bart Maes; Yves Vanrenterghem
Journal:  Blood Purif       Date:  2005-01-06       Impact factor: 2.614

3.  Systemic anticoagulation and bleeding in children with hemodialysis catheters.

Authors:  Michael L Moritz; Abhay Vats; Demetrius Ellis
Journal:  Pediatr Nephrol       Date:  2002-11-21       Impact factor: 3.714

4.  Cefotaxime-heparin lock prophylaxis against hemodialysis catheter-related sepsis among Staphylococcus aureus nasal carriers.

Authors:  Anil K Saxena; Bodh R Panhotra; Abdul Aziz Al-hafiz; Dasappan S Sundaram; Bassam Abu-Oyun; Khalifa Al Mulhim
Journal:  Saudi J Kidney Dis Transpl       Date:  2012-07

5.  An economic evaluation of rt-PA locking solution in dialysis catheters.

Authors:  Braden J Manns; Nairne Scott-Douglas; Marcello Tonelli; Pietro Ravani; Martine LeBlanc; Marc Dorval; Rachel Holden; Louise Moist; Charmaine Lok; Deborah Zimmerman; Flora Au; Brenda R Hemmelgarn
Journal:  J Am Soc Nephrol       Date:  2014-07-10       Impact factor: 10.121

6.  Comparison of alteplase and heparin in maintaining the patency of paediatric central venous haemodialysis lines: a randomised controlled trial.

Authors:  Nicola S Gittins; Yan L Hunter-Blair; John N S Matthews; Malcolm G Coulthard
Journal:  Arch Dis Child       Date:  2006-10-26       Impact factor: 3.791

7.  Prevalence of infection from subclavian dialysis catheters with two different postinsertion catheter cares: a randomized comparative study.

Authors:  S Huraib; A Askar; H Abu-Aisha; J al-Wakeel
Journal:  Angiology       Date:  1994-12       Impact factor: 3.619

8.  Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activator.

Authors:  Brenda R Hemmelgarn; Louise M Moist; Charmaine E Lok; Marcello Tonelli; Braden J Manns; Rachel M Holden; Martine LeBlanc; Peter Faris; Paul Barre; Jianguo Zhang; Nairne Scott-Douglas
Journal:  N Engl J Med       Date:  2011-01-27       Impact factor: 91.245

9.  A randomized double-blind controlled trial of taurolidine-citrate catheter locks for the prevention of bacteremia in patients treated with hemodialysis.

Authors:  Laurie R Solomon; John S Cheesbrough; Leonard Ebah; Tamer Al-Sayed; Michael Heap; Nick Millband; Dee Waterhouse; Sandip Mitra; Alan Curry; Rema Saxena; Rammohan Bhat; Michael Schulz; Peter Diggle
Journal:  Am J Kidney Dis       Date:  2010-03-06       Impact factor: 8.860

10.  Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution.

Authors:  Michiel G H Betjes; Madelon van Agteren
Journal:  Nephrol Dial Transplant       Date:  2004-02-19       Impact factor: 5.992

View more
  8 in total

Review 1.  A narrative review of long-term central venous access devices for the intensivist.

Authors:  David Moir; Andrew Bodenham
Journal:  J Intensive Care Soc       Date:  2017-12-12

Review 2.  Antiplatelet agents in hemodialysis.

Authors:  Massimiliano Migliori; Vincenzo Cantaluppi; Alessia Scatena; Vincenzo Panichi
Journal:  J Nephrol       Date:  2016-12-08       Impact factor: 3.902

3.  Compatibility, Stability, and Efficacy of Vancomycin Combined With Gentamicin or Ethanol in Sodium Citrate as a Catheter Lock Solution.

Authors:  Yangjie Wei; Joshua WonJoon Yang; Sai Hs Boddu; Rose Jung; Mariann D Churchwell
Journal:  Hosp Pharm       Date:  2017-09-01

Review 4.  Anticoagulants and antiplatelet agents for preventing central venous haemodialysis catheter malfunction in patients with end-stage kidney disease.

Authors:  Ying Wang; Jessica N Ivany; Vlado Perkovic; Martin P Gallagher; Mark Woodward; Meg J Jardine
Journal:  Cochrane Database Syst Rev       Date:  2016-04-04

5.  Effectiveness and Cost of Weekly Recombinant Tissue Plasminogen Activator Hemodialysis Catheter Locking Solution.

Authors:  Brenda R Hemmelgarn; Braden J Manns; Steven D Soroka; Adeera Levin; Jennifer MacRae; Karthik Tennankore; Jo-Anne S Wilson; Robert G Weaver; Pietro Ravani; Robert R Quinn; Marcello Tonelli; Mercedeh Kiaii; Paula Mossop; Nairne Scott-Douglas
Journal:  Clin J Am Soc Nephrol       Date:  2018-01-15       Impact factor: 8.237

6.  Pharmacological interventions for preventing clotting of extracorporeal circuits during continuous renal replacement therapy.

Authors:  Hiraku Tsujimoto; Yasushi Tsujimoto; Yukihiko Nakata; Tomoko Fujii; Sei Takahashi; Mai Akazawa; Yuki Kataoka
Journal:  Cochrane Database Syst Rev       Date:  2020-03-13

7.  Substitution of citrate with tissue plasminogen activator (rt-PA) for catheter lock does not improve patency of tunnelled haemodialysis catheters in a randomised trial.

Authors:  Pavlina Richtrova; Jan Mares; Lukas Kielberger; Jan Klaboch; Jaromir Eiselt; Tomas Reischig
Journal:  BMC Nephrol       Date:  2021-01-28       Impact factor: 2.388

8.  The landscape of renal replacement therapy in Veterans Affairs Medical Center intensive care units.

Authors:  Chandan Vangala; Maulin Shah; Natasha N Dave; Layth Al Attar; Sankar D Navaneethan; Venkat Ramanathan; Susan Crowley; Wolfgang C Winkelmayer
Journal:  Ren Fail       Date:  2021-12       Impact factor: 2.606