Pavlina Richtrova1,2, Jan Mares3,4, Lukas Kielberger3,4, Jan Klaboch3,4, Jaromir Eiselt3,4, Tomas Reischig3,4. 1. Department of Internal Medicine I, Faculty of Medicine in Pilsen, Charles University, and Teaching Hospital in Pilsen, Alej Svobody 80, 304 60, Plzen, Czech Republic. richtrovap@fnplzen.cz. 2. Biomedical Centre, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic. richtrovap@fnplzen.cz. 3. Department of Internal Medicine I, Faculty of Medicine in Pilsen, Charles University, and Teaching Hospital in Pilsen, Alej Svobody 80, 304 60, Plzen, Czech Republic. 4. Biomedical Centre, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic.
Abstract
BACKROUND: The study aim was to establish if substitution of citrate with rt-PA for catheter lock once weekly can reduce the incidence of catheter-related blood stream infections (CR-BSI) or improve patency of tunneled haemodialysis catheters. METHODS: All incident patients undergoing insertion of a tunneled haemodialysis catheter were screened and included except those suffering infection or using oral anticoagulation. Study participants were randomized into two arms according to the solution applied as catheter lock: receiving either trisodium citrate (Citra-LockTM 4%) only or rt-PA (Actilyse® 1 mg/ml) on the middle session each week with citrate used on the first and third sessions. The incidence of CR-BSI (confirmed by positive blood culture), catheter non-function (complete obstruction), and malfunction (blood flow < 250 ml/min) was recorded. Statistical significance was tested with ANOVA, post hoc analysis was performed by means of multiple linear regression. RESULTS: Totally, 18 patients were included and followed during 655 haemodialysis sessions. No episode of CR-BSI was detected while 6 catheter non-functions (0.9% sessions) and 101 malfunctions (15.4% sessions) were recorded. The incidence of both events was equal between the study arms: 4 non-functions and 55 malfunctions in the rt-PA arm and 2 non-functions and 46 malfunctions in the citrate arm (p = 0.47 and p = 0.24, respectively). Additionally, the mean blood flow achieved did not differ significantly between the arms: 326 ± 1,8 and 326 ± 1,9 ml/min (p = 0.95) in rt-PA and citrate arms, respectively. Post hoc analysis identified time elapsed since previous session (β = 0.12, p = 0.005) and malfunction on previous session (β = 0.25, p < 0.001) as significant factors affecting the occurrence of malfunction. By contrast, the study arm, rt-PA application on previous session, and catheter vintage did not enter the model. CONCLUSION: Substitution of citrate with rt-PA for catheter lock does not reduce the incidence of catheter malfunction neither does it affect the blood flow achieved during haemodialysis. Catheter patency is related rather to the time interval between sessions and to previous malfunction (thus probably reflecting undefined individual factors). The incidence of CR-BSI within pre-selected haemodialysis population is sporadic (less than 1 per 4.3 patient years in our sample). TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, ACTRN12612000152820 . Retrospectively registered 03/02/2012.
BACKROUND: The study aim was to establish if substitution of citrate with rt-PA for catheter lock once weekly can reduce the incidence of catheter-related blood stream infections (CR-BSI) or improve patency of tunneled haemodialysis catheters. METHODS: All incident patients undergoing insertion of a tunneled haemodialysis catheter were screened and included except those suffering infection or using oral anticoagulation. Study participants were randomized into two arms according to the solution applied as catheter lock: receiving either trisodium citrate (Citra-LockTM 4%) only or rt-PA (Actilyse® 1 mg/ml) on the middle session each week with citrate used on the first and third sessions. The incidence of CR-BSI (confirmed by positive blood culture), catheter non-function (complete obstruction), and malfunction (blood flow < 250 ml/min) was recorded. Statistical significance was tested with ANOVA, post hoc analysis was performed by means of multiple linear regression. RESULTS: Totally, 18 patients were included and followed during 655 haemodialysis sessions. No episode of CR-BSI was detected while 6 catheter non-functions (0.9% sessions) and 101 malfunctions (15.4% sessions) were recorded. The incidence of both events was equal between the study arms: 4 non-functions and 55 malfunctions in the rt-PA arm and 2 non-functions and 46 malfunctions in the citrate arm (p = 0.47 and p = 0.24, respectively). Additionally, the mean blood flow achieved did not differ significantly between the arms: 326 ± 1,8 and 326 ± 1,9 ml/min (p = 0.95) in rt-PA and citrate arms, respectively. Post hoc analysis identified time elapsed since previous session (β = 0.12, p = 0.005) and malfunction on previous session (β = 0.25, p < 0.001) as significant factors affecting the occurrence of malfunction. By contrast, the study arm, rt-PA application on previous session, and catheter vintage did not enter the model. CONCLUSION: Substitution of citrate with rt-PA for catheter lock does not reduce the incidence of catheter malfunction neither does it affect the blood flow achieved during haemodialysis. Catheter patency is related rather to the time interval between sessions and to previous malfunction (thus probably reflecting undefined individual factors). The incidence of CR-BSI within pre-selected haemodialysis population is sporadic (less than 1 per 4.3 patient years in our sample). TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, ACTRN12612000152820 . Retrospectively registered 03/02/2012.
Authors: Marlies Noordzij; Kitty J Jager; Sabine N van der Veer; Reinhard Kramar; Frederic Collart; James G Heaf; Olivera Stojceva-Taneva; Torbjørn Leivestad; Jadranka Buturovic-Ponikvar; Manuel Benítez Sánchez; Fransesc Moreso; Karl G Prütz; Alison Severn; Christoph Wanner; Raymond Vanholder; Pietro Ravani Journal: Nephrol Dial Transplant Date: 2014-07-24 Impact factor: 5.992
Authors: Pietro Ravani; Suetonia C Palmer; Matthew J Oliver; Robert R Quinn; Jennifer M MacRae; Davina J Tai; Neesh I Pannu; Chandra Thomas; Brenda R Hemmelgarn; Jonathan C Craig; Braden Manns; Marcello Tonelli; Giovanni F M Strippoli; Matthew T James Journal: J Am Soc Nephrol Date: 2013-02-21 Impact factor: 10.121
Authors: Brenda R Hemmelgarn; Louise M Moist; Charmaine E Lok; Marcello Tonelli; Braden J Manns; Rachel M Holden; Martine LeBlanc; Peter Faris; Paul Barre; Jianguo Zhang; Nairne Scott-Douglas Journal: N Engl J Med Date: 2011-01-27 Impact factor: 91.245
Authors: Hui Xue; Joachim H Ix; Weiling Wang; Steven M Brunelli; Michael Lazarus; Raymond Hakim; Eduardo Lacson Journal: Am J Kidney Dis Date: 2012-11-16 Impact factor: 8.860
Authors: Laura M Dember; Gerald J Beck; Michael Allon; James A Delmez; Bradley S Dixon; Arthur Greenberg; Jonathan Himmelfarb; Miguel A Vazquez; Jennifer J Gassman; Tom Greene; Milena K Radeva; Gregory L Braden; T Alp Ikizler; Michael V Rocco; Ingemar J Davidson; James S Kaufman; Catherine M Meyers; John W Kusek; Harold I Feldman Journal: JAMA Date: 2008-05-14 Impact factor: 56.272