Literature DB >> 27037563

Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial.

Jaromir Masata1, Kamil Svabik2, Karel Zvara3, Petr Hubka1, Ales Toman4, Alois Martan1.   

Abstract

INTRODUCTION AND HYPOTHESIS: The aim of this study was to compare the efficacy of the tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of stress urinary incontinence in a randomized two-arm study with a 1-year follow-up.
METHODS: This single-centre randomized trial compared the objective and subjective cure rates of TVT-O and Ajust using objective criteria (cough test) and subjective criteria (International Consultation on Incontinence Questionnaire short form, ICIQ-UI SF). The objective cure rate was defined as the number of patients with a negative cough stress test. Subjective cure was defined as no stress leakage of urine after surgery based on the ICIQ-UI SF. The primary outcome was to establish differences in objective and subjective cure rates between the TVT-O and Ajust groups. We also compared postoperative pain profiles using a visual analogue scale (VAS), improvement in quality of life using the ICIQ- UI SF and the Incontinence Quality of Life questionnaire, and overall satisfaction with the surgical procedure using a VAS and a five-item Likert scale. Inclusion criteria were age over 18 years, signed informed consent, and urodynamic stress urinary incontinence. Following a power calculation, 50 patients were enrolled into each group (Ajust and TVT-O).
RESULTS: The mean follow-up after surgery was 445 days (SD 157.6 days) in the TVT-O group and 451.8 days (SD 127.6 days) in the Ajust group (p = 76.6 %). At 1 year, 47 patients were evaluated in the TVT-O group and 49 in the Ajust group. No differences in subjective cure rates or objective cure rates were observed. In the Ajust and TVT-O groups, the rates for no subjective stress leakage were 89.8 % and 91.5 %, respectively (p = 1.0, OR 1.22, 95 % CI 0.24 - 6.58), and the rates for a negative stress test were 89.8 % and 87.2 %, respectively (p = 0.76, OR 0.77, 95 % CI 0.17 - 3.32). In the Ajust group two patients reported de novo pain during sexual intercourse.
CONCLUSIONS: After a 1-year-follow-up, no significant differences were found with regard to subjective and objective outcomes between the single-incision tape Ajust and TVT-O.

Entities:  

Keywords:  Ajust™; Single incision midurethral sling; Stress urinary incontinence; Surgical treatment; TVT-O

Mesh:

Year:  2016        PMID: 27037563     DOI: 10.1007/s00192-016-3012-x

Source DB:  PubMed          Journal:  Int Urogynecol J        ISSN: 0937-3462            Impact factor:   2.894


  31 in total

1.  The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction.

Authors:  R C Bump; A Mattiasson; K Bø; L P Brubaker; J O DeLancey; P Klarskov; B L Shull; A R Smith
Journal:  Am J Obstet Gynecol       Date:  1996-07       Impact factor: 8.661

2.  Presentation and management of major complications of midurethral slings: Are complications under-reported?

Authors:  Donna Y Deng; Matthew Rutman; Shlomo Raz; Larissa V Rodriguez
Journal:  Neurourol Urodyn       Date:  2007       Impact factor: 2.696

3.  Randomized trial of a comparison of the efficacy of TVT-O and single-incision tape TVT SECUR systems in the treatment of stress urinary incontinent women--2-year follow-up.

Authors:  Jaromir Masata; Kamil Svabik; Karel Zvara; Petra Drahoradova; Rachid El Haddad; Petr Hubka; Alois Martan
Journal:  Int Urogynecol J       Date:  2012-10       Impact factor: 2.894

4.  Postoperative pain after adjustable single-incision or transobturator sling for incontinence: a randomized controlled trial.

Authors:  Karlijn J Schweitzer; Alfredo L Milani; Hugo W F van Eijndhoven; Dirk A Gietelink; Eric Hallensleben; Geert-Jan Cromheecke; Carl H van der Vaart
Journal:  Obstet Gynecol       Date:  2015-01       Impact factor: 7.661

5.  A nationwide analysis of complications associated with the tension-free vaginal tape (TVT) procedure.

Authors:  Nina Kuuva; Carl Gustaf Nilsson
Journal:  Acta Obstet Gynecol Scand       Date:  2002-01       Impact factor: 3.636

Review 6.  An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for female pelvic floor dysfunction.

Authors:  Bernard T Haylen; Dirk de Ridder; Robert M Freeman; Steven E Swift; Bary Berghmans; Joseph Lee; Ash Monga; Eckhard Petri; Diaa E Rizk; Peter K Sand; Gabriel N Schaer
Journal:  Int Urogynecol J       Date:  2009-11-25       Impact factor: 2.894

7.  Quality of life of women with urinary incontinence: further development of the incontinence quality of life instrument (I-QOL)

Authors:  D L Patrick; M L Martin; D M Bushnell; I Yalcin; T H Wagner; D P Buesching
Journal:  Urology       Date:  1999-01       Impact factor: 2.649

8.  ICIQ: a brief and robust measure for evaluating the symptoms and impact of urinary incontinence.

Authors:  Kerry Avery; Jenny Donovan; Tim J Peters; Christine Shaw; Momokazu Gotoh; Paul Abrams
Journal:  Neurourol Urodyn       Date:  2004       Impact factor: 2.696

9.  Multicenter prospective randomized study of single-incision mini-sling vs tension-free vaginal tape-obturator in management of female stress urinary incontinence: a minimum of 1-year follow-up.

Authors:  Alyaa Mostafa; Wael Agur; Mohamed Abdel-All; Karen Guerrero; Chu Lim; Mohamed Allam; Mohamed Yousef; James N'Dow; Mohamed Abdel-Fattah
Journal:  Urology       Date:  2013-07-09       Impact factor: 2.649

10.  Novel surgical technique for the treatment of female stress urinary incontinence: transobturator vaginal tape inside-out.

Authors:  Jean de Leval
Journal:  Eur Urol       Date:  2003-12       Impact factor: 20.096

View more
  9 in total

1.  Multicentre randomized trial of the Ajust™ single-incision sling compared to the Align™ transobturator tape sling.

Authors:  Jordi Sabadell; Marta Palau-Gené; Eva Huguet; Anabel Montero-Armengol; Sabina Salicrú; Jose L Poza
Journal:  Int Urogynecol J       Date:  2016-12-05       Impact factor: 2.894

2.  Are the same tapes really the same? Ultrasound study of laser-cut and mechanically cut TVT-O post-operative behavior.

Authors:  Zdenek Rusavy; Jaromir Masata; Kamil Svabik; Petr Hubka; Karel Zvara; Alois Martan
Journal:  Int Urogynecol J       Date:  2017-11-25       Impact factor: 2.894

Review 3.  De novo overactive bladder following midurethral sling procedures: a systematic review of the literature and meta-analysis.

Authors:  Vasilios Pergialiotis; Zini Mudiaga; Despina N Perrea; Stergios K Doumouchtsis
Journal:  Int Urogynecol J       Date:  2017-08-05       Impact factor: 2.894

4.  A randomized comparison of a single-incision needleless (Contasure-needleless®) mini-sling versus an inside-out transobturator (Contasure-KIM®) mid-urethral sling in women with stress urinary incontinence: 24-month follow-up results.

Authors:  Ozan Dogan; Aski Ellibes Kaya; Cigdem Pulatoglu; Alper Basbug; Murat Yassa
Journal:  Int Urogynecol J       Date:  2018-03-16       Impact factor: 2.894

5.  Management of mid-urethral tape complications: a retrospective study.

Authors:  Ifeoma Offiah; Suneetha Rachaneni; Anupreet Dua
Journal:  J Obstet Gynaecol India       Date:  2019-09-07

6.  Adjustable mini-sling compared with conventional mid-urethral slings in women with urinary incontinence: a 3-year follow-up of a randomized controlled trial.

Authors:  Vasileios Alexandridis; Martin Rudnicki; Ulf Jakobsson; Pia Teleman
Journal:  Int Urogynecol J       Date:  2019-06-20       Impact factor: 2.894

7.  Focusing on long-term complications of mid-urethral slings among women with stress urinary incontinence as a patient safety improvement measure: A protocol for systematic review and meta-analysis.

Authors:  Yi-Hao Lin; Cheng-Kai Lee; Shuenn-Dyh Chang; Pei-Chun Chien; Yu-Ying Hsu; Ling-Hong Tseng
Journal:  Medicine (Baltimore)       Date:  2021-06-18       Impact factor: 1.817

8.  Adjustable single-incision mini-slings (Ajust®) versus other slings in surgical management of female stress urinary incontinence: a meta-analysis of effectiveness and complications.

Authors:  Fuding Bai; Jimin Chen; Zhewei Zhang; Yichun Zheng; Jiaming Wen; Xiawa Mao; Nan Zhang
Journal:  BMC Urol       Date:  2018-05-18       Impact factor: 2.264

9.  Ambulatory MiniArc Precise Sling under Local Anesthesia for Stress Urinary Incontinence: Feasibility and Outcome.

Authors:  Miriam Campos-Delgado; Cecilia Quetglas-Muñoz; Marc Barahona-Orpinell; Amparo García-Tejedor; Jordi Ponce-Sebastià
Journal:  Gynecol Minim Invasive Ther       Date:  2019-08-29
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.