Literature DB >> 27028533

Radiation exposure contribution of the scout abdomen radiograph in common pediatric fluoroscopic procedures.

Anil G Rao1, Cephus E Simmons2, Paul G Thacker2, Heather Collins2, E Russell Ritenour2, Jeanne G Hill2.   

Abstract

BACKGROUND: Contrast enema, voiding cystourethrography and upper gastrointestinal studies are the most common fluoroscopic procedures in children. Scout abdomen radiographs have been routinely obtained prior to fluoroscopy and add to the radiation exposure from these procedures. Elimination of unnecessary routine scout radiographs in select studies might significantly reduce radiation exposure to children and improve the overall benefit-to-risk ratio of these fluoroscopic procedures.
OBJECTIVE: To determine the radiation exposure contribution of the preliminary/scout abdomen radiographs with respect to the radiation exposure of the total procedure.
MATERIALS AND METHODS: We retrospectively collected demographic information and radiation exposure values of dose area product (in Gy-cm(2)) and entrance air kerma (in mGy) - initially for the scout abdomen radiographs done prior to fluoroscopy and subsequently the total procedural radiation values (the combined values of the scout radiograph and fluoroscopic radiation exposure) - in children who underwent contrast enemas, voiding cystourethrograms and upper gastrointestinal studies in a 4-month period. The radiation parameters, including fluoroscopy time, dose area product and entrance air kerma, were available in the log book maintained in the fluoroscopy suite. Fluoroscopy procedures were performed on a single fluoroscopy machine using four frames per second pulse rate and other radiation-minimizing techniques. Usage of the grid to obtain scout radiographs was also recorded. The proportion of radiation exposure from the scout radiograph relative to that of the total procedure was calculated by dividing the individual parameters of the scout to the total procedural values and multiplied by 100 to express these values as a percentage. We calculated mean, median and range and performed statistical analysis of the data.
RESULTS: A total of 151 procedures performed on 71 males and 80 females qualified for the study. The age range of the patients was 2 days to 18 years, with a mean of nearly 3.5 years (40 months) and median of 15 months. There were 63 upper gastrointestinal studies, 65 voiding cystourethrography studies and 23 contrast enema studies. The fluoroscopy time for all procedures combined ranged from 0.1 min (6 s) to 2 min, with mean and median values of 0.4 min and 0.3 min, respectively. The fractional radiation exposure contribution for the dose area product of scout abdomen radiograph to the total procedure ranged from 4% to 98%, with mean and median values of 51% and 49%, respectively. The fractional contribution of the scout radiograph to the total procedure for the entrance air kerma values ranged from 6% to 97%, with mean and median values of 29% and 26%, respectively. There was a significant negative correlation (P<0.001) between fluoroscopy radiation time and the proportion of radiation parameters of scout radiograph to total procedural values.
CONCLUSION: Scout radiographs can contribute a significant proportion (median values of approximately 50% for the dose area product and 26% for the entrance air kerma) of radiation exposure in common fluoroscopy procedures in children.

Entities:  

Keywords:  Children; Contrast enema; Fluoroscopy; Radiation dose; Scout radiograph; Upper gastrointestinal series; Voiding cystourethrogram

Mesh:

Substances:

Year:  2016        PMID: 27028533     DOI: 10.1007/s00247-016-3602-2

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  16 in total

Review 1.  Pediatric uroradiology: state of the art.

Authors:  Kassa Darge; J Damien Grattan-Smith; Michael Riccabona
Journal:  Pediatr Radiol       Date:  2010-04-21

2.  The ALARA concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients--a white paper executive summary.

Authors:  Keith J Strauss; Sue C Kaste
Journal:  AJR Am J Roentgenol       Date:  2006-09       Impact factor: 3.959

3.  ALARA in pediatric fluoroscopy.

Authors:  Mahadevappa Mahesh; Nicholas Detorie; Keith J Strauss
Journal:  J Am Coll Radiol       Date:  2007-12       Impact factor: 5.532

4.  Pause and pulse: ten steps that help manage radiation dose during pediatric fluoroscopy.

Authors:  Marta Hernanz-Schulman; Marilyn J Goske; Ishtiaq H Bercha; Keith J Strauss
Journal:  AJR Am J Roentgenol       Date:  2011-08       Impact factor: 3.959

5.  Evaluation of pediatric VCUG at an academic children's hospital: is the radiographic scout image necessary?

Authors:  Jason G Domina; Ramon Sanchez; Indu R Meesa; Emmanuel Christodoulou
Journal:  Pediatr Radiol       Date:  2014-12-14

6.  Effective dose estimation for pediatric upper gastrointestinal examinations using an anthropomorphic phantom set and metal oxide semiconductor field-effect transistor (MOSFET) technology.

Authors:  Brent Emigh; Christopher L Gordon; Bairbre L Connolly; Michelle Falkiner; Karen E Thomas
Journal:  Pediatr Radiol       Date:  2013-03-26

7.  ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology.

Authors:  P-L Khong; H Ringertz; V Donoghue; D Frush; M Rehani; K Appelgate; R Sanchez
Journal:  Ann ICRP       Date:  2013-04

8.  Increased radiation dose to overweight and obese patients from radiographic examinations.

Authors:  Jacquelyn C Yanch; Richard H Behrman; Michael J Hendricks; John H McCall
Journal:  Radiology       Date:  2009-04-29       Impact factor: 11.105

9.  Evaluation of organ and effective doses during paediatric barium meal examinations using PCXMC 2.0 Monte Carlo code.

Authors:  E Yakoumakis; A Dimitriadis; G Gialousis; T Makri; E Karavasilis; N Yakoumakis; E Georgiou
Journal:  Radiat Prot Dosimetry       Date:  2014-05-29       Impact factor: 0.972

10.  Effective dose estimation for pediatric voiding cystourethrography using an anthropomorphic phantom set and metal oxide semiconductor field-effect transistor (MOSFET) technology.

Authors:  Ryan Lee; Karen E Thomas; Bairbre L Connolly; Michelle Falkiner; Christopher L Gordon
Journal:  Pediatr Radiol       Date:  2009-02-25
View more
  3 in total

1.  Intussusception reduction: Effect of air vs. liquid enema on radiation dose.

Authors:  Summer L Kaplan; Dennise Magill; Marc A Felice; J Christopher Edgar; Sudha A Anupindi; Xiaowei Zhu
Journal:  Pediatr Radiol       Date:  2017-06-03

2.  Pre-procedural scout radiographs are unnecessary for routine pediatric fluoroscopic examinations.

Authors:  Sean G Creeden; Anil G Rao; Meryle J Eklund; Jeanne G Hill; Paul G Thacker
Journal:  Pediatr Radiol       Date:  2016-11-17

3.  Radiation dose monitoring in pediatric fluoroscopy: comparison of fluoroscopy time and dose-area product thresholds for identifying high-exposure cases.

Authors:  Matthew S Lazarus; Benjamin H Taragin; William Malouf; Terry L Levin; Eduardo Nororis; Alan H Schoenfeld; Amichai J Erdfarb
Journal:  Pediatr Radiol       Date:  2019-01-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.