Literature DB >> 24876338

Evaluation of organ and effective doses during paediatric barium meal examinations using PCXMC 2.0 Monte Carlo code.

E Yakoumakis1, A Dimitriadis2, G Gialousis3, T Makri4, E Karavasilis1, N Yakoumakis5, E Georgiou1.   

Abstract

Radiation protection and estimation of the radiological risk in paediatric radiology is essential due to children's significant radiosensitivity and their greater overall health risk. The purpose of this study was to estimate the organ and effective doses of paediatric patients undergoing barium meal (BM) examinations and also to evaluate the assessment of radiation Risk of Exposure Induced cancer Death (REID) to paediatric patients undergoing BM examinations. During the BM studies, fluoroscopy and multiple radiographs are involved. Since direct measurements of the dose in each organ are very difficult if possible at all, clinical measurements of dose-area products (DAPs) and the PCXMC 2.0 Monte Carlo code were involved. In clinical measurements, DAPs were assessed during examination of 51 patients undergoing BM examinations, separated almost equally in three age categories, neonatal, 1- and 5-y old. Organs receiving the highest amounts of radiation during BM examinations were as follows: the stomach (10.4, 10.2 and 11.1 mGy), the gall bladder (7.1, 5.8 and 5.2 mGy) and the spleen (7.5, 8.2 and 4.3 mGy). The three values in the brackets correspond to neonatal, 1- and 5-y-old patients, respectively. For all ages, the main contributors to the total organ and effective doses are the fluoroscopy projections. The average DAP values and absorbed doses to patient were higher for the left lateral projections. The REID was calculated for boys (4.8 × 10(-2), 3.0 × 10(-2) and 2.0 × 10(-2) %) for neonatal, 1- and 5-y old patients, respectively. The corresponding values for girl patients were calculated (12.1 × 10(-2), 5.5 × 10(-2) and 3.4 × 10(-2) %).
© The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24876338     DOI: 10.1093/rpd/ncu174

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  1 in total

1.  Radiation exposure contribution of the scout abdomen radiograph in common pediatric fluoroscopic procedures.

Authors:  Anil G Rao; Cephus E Simmons; Paul G Thacker; Heather Collins; E Russell Ritenour; Jeanne G Hill
Journal:  Pediatr Radiol       Date:  2016-03-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.