Literature DB >> 27027801

Mechanical Construct Characteristics Predisposing to Non-union After Locked Lateral Plating of Distal Femur Fractures.

Edward K Rodriguez1, David Zurakowski, Lindsay Herder, Amber Hall, Kempland C Walley, Mike J Weaver, Paul T Appleton, Mark Vrahas.   

Abstract

OBJECTIVES: To identify discrete construct characteristics related to overall construct rigidity that may be independent predictors of nonunion after lateral locked plate (LLP) fixation of distal femur fractures.
DESIGN: Retrospective case-control study.
SETTING: Three level-1 urban trauma centers. PATIENTS/PARTICIPANTS: Two hundred and seventy-one supracondylar femoral fractures treated with LLP at 3 affiliated level 1 urban trauma centers between August 2004 and December 2010.
METHODS: Nonunion was defined as a secondary procedure for poor healing. Construct variables included: (1) combined plate design and material variable, (2) Plate length, (3) # screws proximal to fracture, (4) total screw density (TSD), (5) proximal screw density (PSD), (6) presence of a screw crossing the main fracture, and (7) rigidity score multivariable analysis was performed using logistic regression to identify independent risk factors for nonunion. INTERVENTION: LLP fixation. MAIN OUTCOME MEASURE: Nonunion.
RESULTS: Nonunion rate was 13.3% (n = 36). There was a significant association between plate design/material and nonunion with 41% of stainless constructs and 10% of titanium constructs resulting in a nonunion (P < 0.001). Rigidity scores reached significance (P = 0.001) with constructs resulting in a nonunion having higher scores. No significant univariate differences with respect to number of proximal screws, plate length, total screw density, or proximal screw density were observed between healed fractures and those with nonunion. Results of the multivariate analysis confirmed that the primary significant independent predictor of nonunion was plate design/material (odds ratio, 6.8; 95% CI, 2.9-16.1; P < 0.001).
CONCLUSIONS: When treating distal femur fractures with LLP, combined plate design and material variable has a highly significant influence on the risk of nonunion independent of any other construct variable. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2016        PMID: 27027801     DOI: 10.1097/BOT.0000000000000593

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  11 in total

1.  Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate.

Authors:  Khang H Dang; Connor A Armstrong; Ravi A Karia; Boris A Zelle
Journal:  Int Orthop       Date:  2018-09-29       Impact factor: 3.075

2.  From Bench to Bedside: How Stiff is Too Stiff? Far-cortical Locking or Dynamic Locked Plating May Obviate the Question.

Authors:  Benjamin K Potter
Journal:  Clin Orthop Relat Res       Date:  2016-05-10       Impact factor: 4.176

3.  Fixed-angle plate fixation and autogenous iliac crest graft for repair of distal metaphyseal femoral nonunion.

Authors:  Emma K Landes; Sanjit R Konda; Philipp Leucht; Abhishek Ganta; Kenneth A Egol
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-08-18

4.  Lateral locked plating for distal femur fractures by low-energy trauma: what makes a difference in healing?

Authors:  Sang-Min Kim; Jae-Woo Yeom; Hyung Keun Song; Kyu-Tae Hwang; Ji-Hyo Hwang; Je-Hyun Yoo
Journal:  Int Orthop       Date:  2018-03-16       Impact factor: 3.075

5.  Comparing Intramedullary Nailing Versus Locked Plating in the Treatment of Native Distal Femur Fractures: Is One Superior to the Other?

Authors:  Jaclyn M Jankowski; Patrick F Szukics; Jay K Shah; David M Keller; Robinson E Pires; Frank A Liporace; Richard S Yoon
Journal:  Indian J Orthop       Date:  2021-01-13       Impact factor: 1.251

6.  Scattering and clustering the proximal screw construct in unilateral locking plate osteosynthesis of distal femoral fractures.

Authors:  Jae Hoon Jang; Seung Joon Rhee; Se Bin Jun; Yoon Young Choi
Journal:  Arch Orthop Trauma Surg       Date:  2021-05-20       Impact factor: 2.928

7.  Fixation of periprosthetic or osteoporotic distal femoral fractures with locking plates: a pilot randomised controlled trial.

Authors:  Nikolaos K Kanakaris; Oghofori Obakponovwe; Matija Krkovic; Matt L Costa; David Shaw; Khitish R Mohanty; Robert M West; Peter V Giannoudis
Journal:  Int Orthop       Date:  2018-07-25       Impact factor: 3.075

8.  Infected Non-Union of the Distal Femur.

Authors:  Kishore Vellingiri; Nagakumar J S
Journal:  Cureus       Date:  2021-01-11

9.  Hardware considerations in infection and nonunion management: When and how to revise the fixation.

Authors:  Graeme Hoit; Marissa Bonyun; Aaron Nauth
Journal:  OTA Int       Date:  2020-03-23

10.  A Novel Three-Dimensional Computational Method to Assess Rod Contour Deformation and to Map Bony Fusion in a Lumbopelvic Reconstruction After En-Bloc Sacrectomy.

Authors:  Peter Endre Eltes; Mate Turbucz; Jennifer Fayad; Ferenc Bereczki; György Szőke; Tamás Terebessy; Damien Lacroix; Peter Pal Varga; Aron Lazary
Journal:  Front Surg       Date:  2022-01-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.