Literature DB >> 27026956

EXTENSIVE OSTEOLYSIS AFTER THE USE OF A BIOABSORBABLE SUTURE ANCHOR: CASE REPORT AND LITERATURE REVIEW.

Fabio Farina Dal Molin.   

Abstract

Bioabsorbable implants are very frequently used to treat rotator cuff and shoulder labrum injuries. Many researchers have observed small areas of osteolysis after treating pathological conditions of the shoulder using bioabsorbable anchors. Biological and mechanical theories have been put forward to account for the osteolysis caused by these materials. The case of a patient who was simultaneously treated for a rotator cuff lesion using the double-row technique and a Bankart lesion using bioabsorbable PLLA anchors and Fiber Wire®, and developed extensive osteolysis of the anatomical neck of the humerus, is described. Given that an anchor was used in the glenoid, and this did not present osteolysis, the hypothesis that mechanical factors are important in the etiology of this complication is raised.

Entities:  

Keywords:  Bioabsorbable Implants; Humerus; Osteolysis; Shoulder

Year:  2015        PMID: 27026956      PMCID: PMC4799178          DOI: 10.1016/S2255-4971(15)30442-0

Source DB:  PubMed          Journal:  Rev Bras Ortop        ISSN: 2255-4971


  11 in total

1.  Osteolysis after open shoulder stabilization using a new bio-resorbable bone anchor: a prospective, non-randomized clinical trial.

Authors:  M Müller; M J Kääb; C Villiger; P Holzach
Journal:  Injury       Date:  2002-08       Impact factor: 2.586

2.  Osseous integration of poly-(L-co-D/L-lactide) 70/30 and titanium suture anchors: an experimental study in sheep cancellous bone.

Authors:  M J Kääb; B A Rahn; A Weiler; R Curtis; S M Perren; E Schneider
Journal:  Injury       Date:  2002-08       Impact factor: 2.586

3.  Extensive osteolysis after rotator cuff repair with a bioabsorbable suture anchor: a case report.

Authors:  Dane Glueck; Timothy C Wilson; Darren L Johnson
Journal:  Am J Sports Med       Date:  2005-02-16       Impact factor: 6.202

4.  Arthroscopic and open shoulder stabilization using absorbable implants. A clinical and radiographic comparison of two methods.

Authors:  J Kartus; L Ejerhed; E Funck; K Köhler; N Sernert; J Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1998       Impact factor: 4.342

5.  Nonabsorbable versus absorbable suture anchors for open Bankart repair. A prospective, randomized comparison.

Authors:  W J Warme; R A Arciero; F H Savoie; J M Uhorchak; M Walton
Journal:  Am J Sports Med       Date:  1999 Nov-Dec       Impact factor: 6.202

6.  Bioabsorbable suture anchor (co-polymer 85/15 D,L lactide/glycolide) implanted in bone: correlation of physical/mechanical properties, magnetic resonance imaging, and histological response.

Authors:  O K Balch; M A Collier; L E DeBault; L L Johnson
Journal:  Arthroscopy       Date:  1999-10       Impact factor: 4.772

Review 7.  Adverse tissue reactions to bioabsorbable fixation devices.

Authors:  O M Böstman; H K Pihlajamäki
Journal:  Clin Orthop Relat Res       Date:  2000-02       Impact factor: 4.176

8.  Poly-L-lactic acid tack synovitis after arthroscopic stabilization of the shoulder.

Authors:  Michael Q Freehill; Dana J Harms; Shane M Huber; Dogan Atlihan; Daniel D Buss
Journal:  Am J Sports Med       Date:  2003 Sep-Oct       Impact factor: 6.202

9.  In vitro biocompatibility of bioresorbable polymers: poly(L, DL-lactide) and poly(L-lactide-co-glycolide).

Authors:  A A Ignatius; L E Claes
Journal:  Biomaterials       Date:  1996-04       Impact factor: 12.479

Review 10.  The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery.

Authors:  Hilkka Peltoniemi; Nureddin Ashammakhi; Risto Kontio; Timo Waris; Antero Salo; Christian Lindqvist; Klaus Grätz; Riitta Suuronen
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2002-07
View more
  1 in total

1.  In Vivo Randomized Controlled Study of the Bone Response of All-Suture Anchors and Biocomposite Anchors.

Authors:  Christopher M B Stewart; Haseem Raja; Emma Torrance; Lennard Funk
Journal:  Orthop J Sports Med       Date:  2020-04-23
  1 in total