Literature DB >> 12161317

Osteolysis after open shoulder stabilization using a new bio-resorbable bone anchor: a prospective, non-randomized clinical trial.

M Müller1, M J Kääb, C Villiger, P Holzach.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12161317     DOI: 10.1016/s0020-1383(02)00130-4

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


× No keyword cloud information.
  9 in total

1.  Comparison between metal and biodegradable suture anchors in the arthroscopic treatment of traumatic anterior shoulder instability: a prospective randomized study.

Authors:  Giuseppe Milano; Andrea Grasso; Domenico A Santagada; Maristella F Saccomanno; Laura Deriu; Carlo Fabbriciani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-17       Impact factor: 4.342

Review 2.  Anterior shoulder dislocation.

Authors:  Steven Cutts; Mark Prempeh; Steven Drew
Journal:  Ann R Coll Surg Engl       Date:  2009-01       Impact factor: 1.891

3.  Glenoid rim fracture through anchor points after arthroscopic Bankart repair for shoulder instability.

Authors:  Jin-Young Park; Seung-Jun Lee; Se-Kwan Oh; KyungSoo Oh; YoungMin Noh; Kuen-Tak Suh
Journal:  Int Orthop       Date:  2014-11-29       Impact factor: 3.075

4.  MRI graduation of osseous reaction and drill hole consolidation after arthroscopic Bankart repair with PLLA anchors and the clinical relevance.

Authors:  T Stein; A P Mehling; M Ulmer; C Reck; T Efe; R Hoffmann; A Jäger; F Welsch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-02       Impact factor: 4.342

5.  Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor.

Authors:  T Nusselt; S Freche; H-M Klinger; M H Baums
Journal:  Arch Orthop Trauma Surg       Date:  2010-06-06       Impact factor: 3.067

6.  EXTENSIVE OSTEOLYSIS AFTER THE USE OF A BIOABSORBABLE SUTURE ANCHOR: CASE REPORT AND LITERATURE REVIEW.

Authors:  Fabio Farina Dal Molin
Journal:  Rev Bras Ortop       Date:  2015-12-12

7.  Magnetic resonance appearance of bioabsorbable anchor screws for double row arthroscopic rotator cuff repairs.

Authors:  Aditya C Pawaskar; Aashay Kekatpure; Nam-Su Cho; Yong-Girl Rhee; In-Ho Jeon
Journal:  Indian J Orthop       Date:  2015 Mar-Apr       Impact factor: 1.251

8.  Bioabsorbable suture anchor migration to the acromioclavicular joint: how far can these implants go?

Authors:  Giovanna Medina; Guilherme Garofo; Caio O D'Elia; Alexandre C Bitar; Wagner Castropil; Breno Schor
Journal:  Case Rep Orthop       Date:  2014-07-10

9.  Revision of Failed Rotator Cuff Reconstruction With a Large Humeral Head Cyst.

Authors:  Bashar Reda; Catherine Coady; Ivan Wong
Journal:  Arthrosc Tech       Date:  2017-10-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.