Literature DB >> 27020782

Hamstring graft bacterial contamination during anterior cruciate ligament reconstruction: clinical and microbiological study.

Mohamad Aboelnour Badran1,2, Dalia Mohamed Moemen3,4.   

Abstract

PURPOSE: Autograft preparation for anterior cruciate ligament (ACL) reconstruction has a potential for graft contamination. The purpose of this study was to evaluate the possibility of bacterial contamination of hamstring autograft during preparation and when dropped onto the operating room floor and methods of graft decontamination.
METHODS: Sixty hamstring tendon autograft specimens were used as the test group. Excess tendon not used in the ACL procedure was divided into five segments. One segment, at the completion of preparation, was sent for culture as a control; the remaining four segments were dropped onto the floor adjacent to the surgical field for 15 seconds. One segment was cultured without undergoing any further treatment. Cultures were taken from each segment after immersion in 10 % povidone-iodine solution, 4 % chlorhexidine and bacitracin, respectively, for three minutes. Cultures of a skin swab and floor swab were taken at the same time and place that the ACL was dropped.
RESULTS: Cultures of control graft tissue from ten patients (16.7 %) were positive for bacteria. No patient developed post-operative infection. Ninety organisms were identified, with Staphylococcus epidermidis being the most common isolate. Grafts rinsed in either bacitracin or 4 % chlorhexidine solutions were less likely to be culture positive.
CONCLUSIONS: A high rate of contamination can be expected during autograft preparation for ACL reconstruction. Soaking the hamstring autograft in either bacitracin or 4 % chlorhexidine solution is effective for decontamination, particulary if graft is dropped on the floor.

Entities:  

Keywords:  ACL; Autograft; Contamination; Hamstring; Infection; Sterilisation

Mesh:

Substances:

Year:  2016        PMID: 27020782     DOI: 10.1007/s00264-016-3168-5

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  23 in total

1.  Contaminated anterior cruciate ligament grafts: the efficacy of 3 sterilization agents.

Authors:  M E Molina; D E Nonweiller; J A Evans; J C Delee
Journal:  Arthroscopy       Date:  2000 May-Jun       Impact factor: 4.772

Review 2.  Anterior and posterior cruciate ligament reconstruction in the new millennium: a global perspective.

Authors:  C D Harner; F H Fu; J J Irrgang; T M Vogrin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2001-08-08       Impact factor: 4.342

3.  Infection after ACL reconstruction: what happens when cultures are negative?

Authors:  A D Musso; R G McCormack
Journal:  Clin J Sport Med       Date:  2005-09       Impact factor: 3.638

4.  Outcomes of postoperative septic arthritis after anterior cruciate ligament reconstruction.

Authors:  D R McAllister; R D Parker; A E Cooper; M P Recht; J Abate
Journal:  Am J Sports Med       Date:  1999 Sep-Oct       Impact factor: 6.202

5.  Prospective analysis of preoperative and intraoperative investigations for the diagnosis of infection at the sites of two hundred and two revision total hip arthroplasties.

Authors:  M J Spangehl; B A Masri; J X O'Connell; C P Duncan
Journal:  J Bone Joint Surg Am       Date:  1999-05       Impact factor: 5.284

6.  Functional outcome of septic arthritis after anterior cruciate ligament surgery.

Authors:  Justus Gille; Ulf Gerlach; Ralf Oheim; Thorben Hintze; Bastian Himpe; Arndt-Peter Schultz
Journal:  Int Orthop       Date:  2014-11-25       Impact factor: 3.075

7.  Septic arthritis after arthroscopic anterior cruciate ligament reconstruction. Diagnosis and management.

Authors:  R J Williams; C T Laurencin; R F Warren; A C Speciale; B D Brause; S O'Brien
Journal:  Am J Sports Med       Date:  1997 Mar-Apr       Impact factor: 6.202

8.  Multiple arthroscopic debridement and graft retention in septic knee arthritis after ACL reconstruction: a prospective case-control study.

Authors:  Ahmed Abdel-Aziz; Yasser A Radwan; Ahmed Rizk
Journal:  Int Orthop       Date:  2013-10-08       Impact factor: 3.075

9.  C-reactive protein (CRP) levels after elective orthopedic surgery.

Authors:  S Larsson; U Thelander; S Friberg
Journal:  Clin Orthop Relat Res       Date:  1992-02       Impact factor: 4.176

10.  Presentation, outcome, and cause of septic arthritis after anterior cruciate ligament reconstruction: a case control study.

Authors:  Maria Schollin-Borg; Karl Michaëlsson; Hans Rahme
Journal:  Arthroscopy       Date:  2003-11       Impact factor: 4.772

View more
  9 in total

1.  Does a different dose of gamma irradiation have the same effect on five different types of tendon allografts? - a biomechanical study.

Authors:  Gyorgy Hangody; Gábor Szebényi; Bence Abonyi; Rita Kiss; László Hangody; Károly Pap
Journal:  Int Orthop       Date:  2016-11-15       Impact factor: 3.075

Review 2.  Orthopaedic publications from Egypt in the last five years: a bibliometric report.

Authors:  Hatem G Said; Mohamed Abd El-Radi; Mohamed Y Hassanein; Galal Z Said
Journal:  Int Orthop       Date:  2018-09-18       Impact factor: 3.075

3.  Contamination occurs during ACL graft harvesting and manipulation, but it can be easily eradicated.

Authors:  Daniel Pérez-Prieto; María E Portillo; Raúl Torres-Claramunt; Xavier Pelfort; Pedro Hinarejos; Joan C Monllau
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-10-07       Impact factor: 4.342

4.  Allograft contamination during suture preparation for anterior cruciate ligament reconstruction: an ex vivo study.

Authors:  Chenliang Wu; Xiuyuan Zhang; Yi Qiao; Jiebo Chen; Wei Su; Junjie Xu; Zipeng Ye; Jia Jiang; Caiqi Xu; Guoming Xie; Jinzhong Zhao; Song Zhao
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-02-23       Impact factor: 4.342

5.  Does Vancomycin Wrapping in Anterior Cruciate Ligament Reconstruction Affect Tenocyte Activity In Vitro?

Authors:  Rocco Papalia; Claudia Cicione; Fabrizio Russo; Luca Ambrosio; Giuseppina Di Giacomo; Gianluca Vadalà; Vincenzo Denaro
Journal:  Antibiotics (Basel)       Date:  2021-09-08

6.  Hamstring autografts are associated with a high rate of contamination in anterior cruciate ligament reconstruction.

Authors:  Abdulaziz Z Alomar; Saud M Alfayez; Ali M Somily
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-29       Impact factor: 4.342

Review 7.  Comparison of the Sterilization Efficiency of 3 Disinfectants for Dropped Anterior Cruciate Ligament Grafts: A Systematic Review and Meta-analysis.

Authors:  Xianyue Shen; Yanguo Qin; Jianlin Zuo; Tong Liu; Jianlin Xiao
Journal:  Orthop J Sports Med       Date:  2021-05-10

8.  Delayed Tibial Osteomyelitis after Anterior Cruciate Ligament Reconstruction with Hamstrings Autograft and Bioabsorbable Interference Screw: A Case Report and Review of the Literature.

Authors:  Kevin S Weiss; Justin M Weatherall; Jen Eick; James R Ross
Journal:  Case Rep Orthop       Date:  2017-10-15

9.  Hamstring Tendon Autograft Contamination in Anterior Cruciate Ligament Reconstruction: Comparison between two Harvesting Techniques.

Authors:  Eduardo Frois Temponi; Luís Henrique Grassi Marques da Costa; Luiz Fernando Machado Soares; Lúcio Honório de Carvalho Júnior
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2019-03-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.