Literature DB >> 10802474

Contaminated anterior cruciate ligament grafts: the efficacy of 3 sterilization agents.

M E Molina1, D E Nonweiller, J A Evans, J C Delee.   

Abstract

PURPOSE: A study was undertaken to determine the incidence of positive cultures resulting from an anterior cruciate ligament (ACL) specimen dropped on the operating room floor and the efficacy of sterilizing the specimen by soaking in 1 of 3 antimicrobial solutions: an antibiotic solution of neomycin and polymyxin B, 10% providone-iodine solution, and standard chlorhexidine gluconate solution. TYPE OF STUDY: Randomized trial.
MATERIALS AND METHODS: Fifty ACL specimens removed from patients undergoing total knee arthroplasty were used as the test group. The specimens were longitudinally sectioned into 4 equal pieces. The 4 pieces were dropped on the floor and left for a period of 15 seconds. Cultures were taken from each specimen after immersion in 1 of the 3 sterilization solutions for a period of 90 seconds. One of the 4 specimens was cultured without being exposed to any solution, thereby establishing these specimens as the control group. Cultures of a floor swab were taken at the same time and place that the ACL was dropped.
RESULTS: The floor swab cultures were positive in 48 of the 50 specimens (96%). The ACL control group (untreated dropped grafts) had 29 of 50 specimens positive (58%). The grafts soaked in antibiotic solution had 3 of 50 specimens positive (6%). The grafts soaked in providone-iodine solution had 12 of 50 specimens positive (24%). The grafts soaked in chlorhexidine gluconate solution had 1 of 50 specimens positive (in broth only) (2%).
CONCLUSION: This study shows that significant contamination occurs when dropping specimens on the floor, as 58% of the dropped grafts had positive cultures. Of the 3 sterilization techniques used, chlorhexidine gluconate seems to be the most efficient with only a single broth culture (2%) found to be positive. The antibiotic solution was second best (6%), although there is no statistically significant difference between these 2 groups. The 10% providone-iodine solution under these test conditions was the least effective of all the 3 sterilization agents with 24% cultures positive after immersion.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10802474     DOI: 10.1016/s0749-8063(00)90081-1

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  11 in total

1.  Evaluation of sterilization methods following contamination of hamstring autograft during anterior cruciate ligament reconstruction.

Authors:  Matthew J Plante; Xinning Li; Gail Scully; Michael A Brown; Brian D Busconi; Nicola A DeAngelis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-15       Impact factor: 4.342

2.  Toxic effects of povidone-iodine on synovial cell and articular cartilage.

Authors:  Masashi Kataoka; Hiroshi Tsumura; Nobuhiro Kaku; Takehiko Torisu
Journal:  Clin Rheumatol       Date:  2005-12-20       Impact factor: 2.980

3.  Intra-operative hamstring tendon graft contamination in anterior cruciate ligament reconstruction.

Authors:  Iosif Gavriilidis; Emilios E Pakos; Benjamin Wipfler; Ioannis S Benetos; Hans H Paessler
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-06-18       Impact factor: 4.342

4.  Remodeling of ACL allografts is inhibited by peracetic acid sterilization.

Authors:  Sven U Scheffler; Johannes Gonnermann; Julia Kamp; Dorothea Przybilla; Axel Pruss
Journal:  Clin Orthop Relat Res       Date:  2008-05-20       Impact factor: 4.176

5.  Hamstring graft bacterial contamination during anterior cruciate ligament reconstruction: clinical and microbiological study.

Authors:  Mohamad Aboelnour Badran; Dalia Mohamed Moemen
Journal:  Int Orthop       Date:  2016-03-29       Impact factor: 3.075

Review 6.  Comparison of the Sterilization Efficiency of 3 Disinfectants for Dropped Anterior Cruciate Ligament Grafts: A Systematic Review and Meta-analysis.

Authors:  Xianyue Shen; Yanguo Qin; Jianlin Zuo; Tong Liu; Jianlin Xiao
Journal:  Orthop J Sports Med       Date:  2021-05-10

7.  Management of a dropped autologous skin graft.

Authors:  Ronald M Brooks; Donald R Herdt; Morton Kasdan
Journal:  Eplasty       Date:  2014-09-27

8.  Effect of three different sterilizing solutions on the contaminated bone: an experimental study in the rabbit.

Authors:  Hamidreza Yazdi; Mehdi Ramezan Shirazi; Omid Momen Shouli; Farzad Yazdi; Alireza Moslem
Journal:  Med J Islam Repub Iran       Date:  2012-08

9.  Contaminated osteochondral plugs: effect of different sterilizing solutions: an experimental study in the rabbit.

Authors:  Hamidreza Yazdi; Mehdi Ramezan Shirazi; Gholamreza Shafiee; Masoumeh Shahcheraghi
Journal:  Med J Islam Repub Iran       Date:  2012-11

10.  Management of contaminated autologous grafts in plastic surgery.

Authors:  Robert F Centeno; Ankit R Desai; Marla E Watson
Journal:  Eplasty       Date:  2008-04-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.