Literature DB >> 27011460

Histopathological Response and Adhesion Formation After Omentectomy with Ultrasonic Energy, Bipolar Sealing, and Suture Ligation.

Gultekin Ozan Kucuk1, Metin Ertem2, Nuray Kepil3.   

Abstract

This study was designed to evaluate the histopathological response and intra-abdominal adhesion formation after an omentectomy in rats using the bipolar vessel-sealing device, ultrasonic coagulator, and suture ligation techniques. Forty Wistar albino rats were used, divided into four random groups. The rats underwent a midline laparotomy, and a partial omentectomy was performed using a 3-0 silk suture with suture ligation in group 1, bipolar device in group 2, and ultrasonic coagulator in group 3; only a laparotomy was performed on the control group. Lateral thermal damage was examined the same day, and a piece of the omentum was left in the animals to be examined on postoperative day 15. A relaparotomy was performed to assess adhesion formation and histopathological response. In pairwise comparisons, there was no statistically significant difference among the ultrasonic device, bipolar device, and suture ligation groups in terms of microscopic adhesion scoring; however, the scores of the bipolar device and suture ligation groups were significantly higher compared with those of the control group (p < 0.01). Furthermore, the macroscopic adhesion scores were significantly lower for the ultrasonic device group when compared with those of the bipolar device and suture ligation groups (p < 0.05 and p < 0.01). The ultrasonic device seems to be superior to the bipolar device and suture ligation in terms of macroscopic adhesion formation, but no significant difference was found in terms of the histopathological response in rats following an omentectomy. Further research may be required.

Entities:  

Keywords:  Adhesion; Electrosurgery; Omentum; Peritoneum

Year:  2013        PMID: 27011460      PMCID: PMC4775706          DOI: 10.1007/s12262-013-1005-2

Source DB:  PubMed          Journal:  Indian J Surg        ISSN: 0973-9793            Impact factor:   0.656


  27 in total

1.  Comparison of thermal spread after ureteral ligation with the Laparo-Sonic ultrasonic shears and the Ligasure system.

Authors:  Sharon L Goldstein; Kristi L Harold; Alan Lentzner; Brent D Matthews; Kent W Kercher; Ronald F Sing; Broc Pratt; Edward H Lipford; B Todd Heniford
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2002-02       Impact factor: 1.878

2.  Comparison of monopolar electrocoagulation, bipolar electrocoagulation, Ultracision, and Ligasure.

Authors:  Theodore Diamantis; Michael Kontos; Antonios Arvelakis; Spiridon Syroukis; Dimitris Koronarchis; Apostolos Papalois; Emmanuel Agapitos; Elias Bastounis; Andreas C Lazaris
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

3.  Comparison of four energy-based vascular sealing and cutting instruments: A porcine model.

Authors:  Benjamin Person; David A Vivas; Dan Ruiz; Michael Talcott; James E Coad; Steven D Wexner
Journal:  Surg Endosc       Date:  2007-12-20       Impact factor: 4.584

4.  Tissue response to surgical energy devices.

Authors:  Courtney K Phillips; Gregory W Hruby; Evren Durak; Daniel S Lehman; Peter A Humphrey; Mahesh M Mansukhani; Jaime Landman
Journal:  Urology       Date:  2008-03-04       Impact factor: 2.649

5.  Laparoscopic transperitoneal adrenalectomy using the LigaSure vessel sealing system.

Authors:  Nihat Yavuz
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2005-12       Impact factor: 1.878

6.  High-burst-strength, feedback-controlled bipolar vessel sealing.

Authors:  J S Kennedy; P L Stranahan; K D Taylor; J G Chandler
Journal:  Surg Endosc       Date:  1998-06       Impact factor: 4.584

Review 7.  Peritoneal adhesions: etiology, pathophysiology, and clinical significance. Recent advances in prevention and management.

Authors:  T Liakakos; N Thomakos; P M Fine; C Dervenis; R L Young
Journal:  Dig Surg       Date:  2001       Impact factor: 2.588

8.  Long-term prognosis after operation for adhesive small bowel obstruction.

Authors:  Bjørg-Tilde Svanes Fevang; Jonas Fevang; Stein Atle Lie; Odd Søreide; Knut Svanes; Asgaut Viste
Journal:  Ann Surg       Date:  2004-08       Impact factor: 12.969

9.  Reduction of adhesion formation in rabbits by intraperitoneal administration of lazaroid formulations.

Authors:  K E Rodgers; W Girgis; K St Amand; J Campeau; G S diZerega
Journal:  Hum Reprod       Date:  1998-09       Impact factor: 6.918

10.  Cyclooxygenase-2 is expressed in human fibroblasts isolated from intraperitoneal adhesions but not from normal peritoneal tissues.

Authors:  Ghassan M Saed; Adnan R Munkarah; Michael P Diamond
Journal:  Fertil Steril       Date:  2003-06       Impact factor: 7.329

View more