Literature DB >> 26995273

The effect of the angle of acuteness of additive manufactured models and the direction of printing on the dimensional fidelity: clinical implications.

Yoshiaki Ide1, Suresh Nayar2,3, Heather Logan2, Brendan Gallagher2, Johan Wolfaardt2,3.   

Abstract

The influence of the acuteness of the model angle and the direction of printing was investigated on different three-dimensional (3D) printers to understand the fidelity of 3D printing. A Polyjet printer and two fused deposition modeling printers were used in the present study. Computer-aided design (CAD) models were designed in the form of a triangular prism with a height of 15 mm and with varying angles of 60°, 45°, 30°, 20°, 10°, and 5°. From the CAD designs, additive manufacturing (AM) models were printed in three different directions by each of the three printers. To investigate the global fidelity of the 3D printers, the height and surface outlines of the AM model cross sections were measured. The fidelity of the AM models with increasingly acute angles was not accurately reproduced when 3D printed, and the surface outlines of the AM model cross sections were different in each direction of printing for each device. Printing technology and printing direction need to be considered if accurate reproduction of acute angles in fine AM structures in medical models is a necessity.

Keywords:  3D printer; 3D printing; Additive manufacturing; Fidelity; Rapid prototyping

Mesh:

Year:  2016        PMID: 26995273     DOI: 10.1007/s10266-016-0239-4

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  16 in total

1.  Analysis of errors in medical rapid prototyping models.

Authors:  J Y Choi; J H Choi; N K Kim; Y Kim; J K Lee; M K Kim; J H Lee; M J Kim
Journal:  Int J Oral Maxillofac Surg       Date:  2002-02       Impact factor: 2.789

Review 2.  The future of dental devices is digital.

Authors:  Richard van Noort
Journal:  Dent Mater       Date:  2011-11-26       Impact factor: 5.304

3.  Dimensional error of selective laser sintering, three-dimensional printing and PolyJet models in the reproduction of mandibular anatomy.

Authors:  Danilo Ibrahim; Tiago Leonardo Broilo; Claiton Heitz; Marília Gerhardt de Oliveira; Helena Willhelm de Oliveira; Stella Maris Wanderlei Nobre; José Henrique Gomes Dos Santos Filho; Daniela Nascimento Silva
Journal:  J Craniomaxillofac Surg       Date:  2008-12-03       Impact factor: 2.078

4.  Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques.

Authors:  Aletta Hazeveld; James J R Huddleston Slater; Yijin Ren
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-01       Impact factor: 2.650

5.  Evaluation of the effect of computed tomography scan protocols and freeform fabrication methods on bone biomodel accuracy.

Authors:  Kathryn L Fitzwater; Denis J Marcellin-Little; Ola L A Harrysson; Jason A Osborne; E Christine Poindexter
Journal:  Am J Vet Res       Date:  2011-09       Impact factor: 1.156

6.  3D virtual endoscopy of the upper airway: optimization of the scan parameters in a cadaver phantom and clinical assessment.

Authors:  J Rodenwaldt; L Kopka; R Roedel; A Margas; E Grabbe
Journal:  J Comput Assist Tomogr       Date:  1997 May-Jun       Impact factor: 1.826

7.  Sensitivity analysis of geometric errors in additive manufacturing medical models.

Authors:  Jose Miguel Pinto; Cristobal Arrieta; Marcelo E Andia; Sergio Uribe; Jorge Ramos-Grez; Alex Vargas; Pablo Irarrazaval; Cristian Tejos
Journal:  Med Eng Phys       Date:  2015-01-31       Impact factor: 2.242

8.  Accuracy of medical models made by additive manufacturing (rapid manufacturing).

Authors:  Mika Salmi; Kaija-Stiina Paloheimo; Jukka Tuomi; Jan Wolff; Antti Mäkitie
Journal:  J Craniomaxillofac Surg       Date:  2013-01-18       Impact factor: 2.078

9.  Clinical feasibility of computer-aided surgical simulation (CASS) in the treatment of complex cranio-maxillofacial deformities.

Authors:  Jaime Gateno; James J Xia; John F Teichgraeber; Andrew M Christensen; Jeremy J Lemoine; Michael A K Liebschner; Michael J Gliddon; Michaelanne E Briggs
Journal:  J Oral Maxillofac Surg       Date:  2007-04       Impact factor: 1.895

10.  Anatomical examination of the fibula: digital imaging study for osseointegrated implant installation.

Authors:  Yoshiaki Ide; Satoru Matsunaga; Jeffrey Harris; Daniel O' Connell; Hadi Seikaly; Johan Wolfaardt
Journal:  J Otolaryngol Head Neck Surg       Date:  2015-02-03
View more
  7 in total

1.  Letter to the editor.

Authors: 
Journal:  J Orofac Orthop       Date:  2018-03       Impact factor: 1.938

2.  Assessment of different types of intra oral scanners and 3D printers on the accuracy of printed models: An in vitro study.

Authors:  Fernando Igai; Washington-Steagall Junior; Carolina-Mayumi Iegami; Pedro-Tortamano Neto
Journal:  J Clin Exp Dent       Date:  2021-12-01

3.  Compressive and Flexural Strength of 3D-Printed and Conventional Resins Designated for Interim Fixed Dental Prostheses: An In Vitro Comparison.

Authors:  Mihaela Pantea; Robert Cătălin Ciocoiu; Maria Greabu; Alexandra Ripszky Totan; Marina Imre; Ana Maria Cristina Țâncu; Ruxandra Sfeatcu; Tudor Claudiu Spînu; Radu Ilinca; Alexandru Eugen Petre
Journal:  Materials (Basel)       Date:  2022-04-23       Impact factor: 3.748

Review 4.  A Review on the Biocompatibility of PMMA-Based Dental Materials for Interim Prosthetic Restorations with a Glimpse into their Modern Manufacturing Techniques.

Authors:  Silviu Mirel Pituru; Maria Greabu; Alexandra Totan; Marina Imre; Mihaela Pantea; Tudor Spinu; Ana Maria Cristina Tancu; Nicoleta Olivia Popoviciu; Iulia-Ioana Stanescu; Ecaterina Ionescu
Journal:  Materials (Basel)       Date:  2020-06-28       Impact factor: 3.623

5.  Biochemical Interaction between Materials Used for Interim Prosthetic Restorations and Saliva.

Authors:  Mihaela Pantea; Alexandra Ripszky Totan; Marina Imre; Alexandru Eugen Petre; Ana Maria Cristina Țâncu; Cristian Tudos; Alexandru Titus Farcașiu; Mihai Butucescu; Tudor Claudiu Spînu
Journal:  Materials (Basel)       Date:  2021-12-29       Impact factor: 3.623

6.  Accuracy of Additively Manufactured and Milled Interim 3-Unit Fixed Dental Prostheses.

Authors:  Duygu Karasan; Juan Legaz; Philippe Boitelle; Philippe Mojon; Vincent Fehmer; Irena Sailer
Journal:  J Prosthodont       Date:  2022-03       Impact factor: 3.485

7.  Strength and Performance Enhancement of Multilayers by Spatial Tailoring of Adherend Compliance and Morphology via Multimaterial Jetting Additive Manufacturing.

Authors:  Jabir Ubaid; Brian L Wardle; S Kumar
Journal:  Sci Rep       Date:  2018-09-11       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.