Literature DB >> 26989895

Collagen Matrix Remodeling in Stented Pulmonary Arteries after Transapical Heart Valve Replacement.

Samaneh Ghazanfari1, Anita Driessen-Mol, Simon P Hoerstrup, Frank P T Baaijens, Carlijn V C Bouten.   

Abstract

The use of valved stents for minimally invasive replacement of semilunar heart valves is expected to change the extracellular matrix and mechanical function of the native artery and may thus impair long-term functionality of the implant. Here we investigate the impact of the stent on matrix remodeling of the pulmonary artery in a sheep model, focusing on matrix composition and collagen (re)orientation of the host tissue. Ovine native pulmonary arteries were harvested 8 (n = 2), 16 (n = 4) and 24 (n = 2) weeks after transapical implantation of self-expandable stented heart valves. Second harmonic generation (SHG) microscopy was used to assess the collagen (re)orientation of fresh tissue samples. The collagen and elastin content was quantified using biochemical assays. SHG microscopy revealed regional differences in collagen organization in all explants. In the adventitial layer of the arterial wall far distal to the stent (considered as the control tissue), we observed wavy collagen fibers oriented in the circumferential direction. These circumferential fibers were more straightened in the adventitial layer located behind the stent. On the luminal side of the wall behind the stent, collagen fibers were aligned along the stent struts and randomly oriented between the struts. Immediately distal to the stent, however, fibers on both the luminal and the adventitial side of the wall were oriented in the axial direction, demonstrating the stent impact on the collagen structure of surrounding arterial tissues. Collagen orientation patterns did not change with implantation time, and biochemical analyses showed no changes in the trend of collagen and elastin content with implantation time or location of the vascular wall. We hypothesize that the collagen fibers on the adventitial side of the arterial wall and behind the stent straighten in response to the arterial stretch caused by oversizing of the stent. However, the collagen organization on the luminal side suggests that stent-induced remodeling is dominated by contact guidance.
© 2016 S. Karger AG, Basel.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26989895      PMCID: PMC5296926          DOI: 10.1159/000442521

Source DB:  PubMed          Journal:  Cells Tissues Organs        ISSN: 1422-6405            Impact factor:   2.481


  40 in total

1.  Functional living trileaflet heart valves grown in vitro.

Authors:  S P Hoerstrup; R Sodian; S Daebritz; J Wang; E A Bacha; D P Martin; A M Moran; K J Guleserian; J S Sperling; S Kaushal; J P Vacanti; F J Schoen; J E Mayer
Journal:  Circulation       Date:  2000-11-07       Impact factor: 29.690

2.  Three-dimensional high-resolution second-harmonic generation imaging of endogenous structural proteins in biological tissues.

Authors:  Paul J Campagnola; Andrew C Millard; Mark Terasaki; Pamela E Hoppe; Christian J Malone; William A Mohler
Journal:  Biophys J       Date:  2002-01       Impact factor: 4.033

3.  Live tissue intrinsic emission microscopy using multiphoton-excited native fluorescence and second harmonic generation.

Authors:  Warren R Zipfel; Rebecca M Williams; Richard Christie; Alexander Yu Nikitin; Bradley T Hyman; Watt W Webb
Journal:  Proc Natl Acad Sci U S A       Date:  2003-05-19       Impact factor: 11.205

4.  Minimally-invasive implantation of living tissue engineered heart valves: a comprehensive approach from autologous vascular cells to stem cells.

Authors:  Dörthe Schmidt; Petra E Dijkman; Anita Driessen-Mol; Rene Stenger; Christine Mariani; Arja Puolakka; Marja Rissanen; Thorsten Deichmann; Bernhard Odermatt; Benedikt Weber; Maximilian Y Emmert; Gregor Zund; Frank P T Baaijens; Simon P Hoerstrup
Journal:  J Am Coll Cardiol       Date:  2010-08-03       Impact factor: 24.094

5.  Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.

Authors:  Gerhard A Holzapfel; Michael Stadler; Thomas C Gasser
Journal:  J Biomech Eng       Date:  2005-02       Impact factor: 2.097

6.  An in vitro model system to quantify stress generation, compaction, and retraction in engineered heart valve tissue.

Authors:  Marijke A A van Vlimmeren; Anita Driessen-Mol; Cees W J Oomens; Frank P T Baaijens
Journal:  Tissue Eng Part C Methods       Date:  2011-07-01       Impact factor: 3.056

Review 7.  The role of growth factors in wound healing.

Authors:  D L Steed
Journal:  Surg Clin North Am       Date:  1997-06       Impact factor: 2.741

8.  In Vivo Collagen Remodeling in the Vascular Wall of Decellularized Stented Tissue-Engineered Heart Valves.

Authors:  Samaneh Ghazanfari; Anita Driessen-Mol; Bart Sanders; Petra E Dijkman; Simon P Hoerstrup; Frank P T Baaijens; Carlijn V C Bouten
Journal:  Tissue Eng Part A       Date:  2015-07-14       Impact factor: 3.845

9.  Use of X-ray diffraction in study of human diabetic and aging collagen.

Authors:  V J James; L Delbridge; S V McLennan; D K Yue
Journal:  Diabetes       Date:  1991-03       Impact factor: 9.461

10.  Enhanced extracellular matrix accumulation in restenosis of coronary arteries after stent deployment.

Authors:  Ick-Mo Chung; Herman K Gold; Stephen M Schwartz; Yuji Ikari; Michael A Reidy; Thomas N Wight
Journal:  J Am Coll Cardiol       Date:  2002-12-18       Impact factor: 24.094

View more
  4 in total

1.  Ex Vivo Regional Mechanical Characterization of Porcine Pulmonary Arteries.

Authors:  N R Pillalamarri; S S Patnaik; S Piskin; P Gueldner; E A Finol
Journal:  Exp Mech       Date:  2021-01-07       Impact factor: 2.808

2.  Alteration of structural and mechanical properties of the temporomandibular joint disc following elastase digestion.

Authors:  Sepanta Fazaeli; Fereshteh Mirahmadi; Vincent Everts; Theodoor H Smit; Jan H Koolstra; Samaneh Ghazanfari
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-06-01       Impact factor: 3.368

3.  Optical coherence tomography and multiphoton microscopy offer new options for the quantification of fibrotic aortic valve disease in ApoE-/- mice.

Authors:  Anett Jannasch; Christian Schnabel; Roberta Galli; Saskia Faak; Petra Büttner; Claudia Dittfeld; Sems Malte Tugtekin; Edmund Koch; Klaus Matschke
Journal:  Sci Rep       Date:  2021-03-12       Impact factor: 4.379

4.  Native extracellular matrix orientation determines multipotent vascular stem cell proliferation in response to cyclic uniaxial tensile strain and simulated stent indentation.

Authors:  P S Mathieu; E Fitzpatrick; M Di Luca; P A Cahill; C Lally
Journal:  Biochem Biophys Rep       Date:  2021-12-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.