Literature DB >> 26989457

A wear simulation study of nanostructured CVD diamond-on-diamond articulation involving concave/convex mating surfaces.

Paul A Baker1, Raymond G Thompson1, Shane A Catledge2.   

Abstract

Using microwave-plasma Chemical Vapor Deposition (CVD), a 3-micron thick nanostructured-diamond (NSD) layer was deposited onto polished, convex and concave components that were machined from Ti-6Al-4V alloy. These components had the same radius of curvature, 25.4mm. Wear testing of the surfaces was performed by rotating articulation of the diamond-deposited surfaces (diamond-on-diamond) with a load of 225N for a total of 5 million cycles in bovine serum resulting in polishing of the diamond surface and formation of very shallow, linear wear grooves of less than 50nm depth. The two diamond surfaces remained adhered to the components and polished each other to an average surface roughness that was reduced by as much as a factor of 80 for the most polished region located at the center of the condyle. Imaging of the surfaces showed that the initial wearing-in phase of diamond was only beginning at the end of the 5 million cycles. Atomic force microscopy, scanning electron microscopy, Raman spectroscopy, and surface profilometry were used to characterize the surfaces and verify that the diamond remained intact and uniform over the surface, thereby protecting the underlying metal. These wear simulation results show that diamond deposition on Ti alloy has potential application for joint replacement devices with improved longevity over existing devices made of cobalt chrome and ultra-high molecular weight polyethylene (UHMWPE).

Entities:  

Year:  2015        PMID: 26989457      PMCID: PMC4790821          DOI: 10.1007/s11998-015-9738-4

Source DB:  PubMed          Journal:  J Coat Technol Res        ISSN: 1935-3804            Impact factor:   2.382


  11 in total

1.  Mechanical wear behavior of nanocrystalline and multilayer diamond coatings on temporomandibular joint implants.

Authors:  Malesela J Papo; Shane A Catledge; Yogesh K Vohra; Camilo Machado
Journal:  J Mater Sci Mater Med       Date:  2004-07       Impact factor: 3.896

2.  Kaiser Permanente National Total Joint Replacement Registry: aligning operations with information technology.

Authors:  Elizabeth W Paxton; Maria C S Inacio; Monti Khatod; Eric J Yue; Robert S Namba
Journal:  Clin Orthop Relat Res       Date:  2010-10       Impact factor: 4.176

3.  Reaction strains on the condylar neck during mastication and maximum muscle stimulation in different condylar positions: an experimental study in the miniature pig.

Authors:  L Marks; S Teng; J Artun; S Herring
Journal:  J Dent Res       Date:  1997-07       Impact factor: 6.116

4.  Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.

Authors:  I C Clarke; V Good; P Williams; D Schroeder; L Anissian; A Stark; H Oonishi; J Schuldies; G Gustafson
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

5.  Improved adhesion of ultra-hard carbon films on cobalt-chromium orthopaedic implant alloy.

Authors:  Shane A Catledge; Rishi Vaid; Patrick Diggins; Jeffrey J Weimer; Mark Koopman; Yogesh K Vohra
Journal:  J Mater Sci Mater Med       Date:  2011-01-08       Impact factor: 3.896

6.  The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene.

Authors:  J Fisher; P Firkins; E A Reeves; J L Hailey; G H Isaac
Journal:  Proc Inst Mech Eng H       Date:  1995       Impact factor: 1.617

Review 7.  The human mandible: lever or link?

Authors:  W L Hylander
Journal:  Am J Phys Anthropol       Date:  1975-09       Impact factor: 2.868

8.  Insall Award paper. Why are total knee arthroplasties failing today?

Authors:  Peter F Sharkey; William J Hozack; Richard H Rothman; Shani Shastri; Sidney M Jacoby
Journal:  Clin Orthop Relat Res       Date:  2002-11       Impact factor: 4.176

9.  Mandibular biomechanics and temporomandibular joint function in primates.

Authors:  R J Smith
Journal:  Am J Phys Anthropol       Date:  1978-09       Impact factor: 2.868

10.  The role of patient factors and implant position in squeaking of ceramic-on-ceramic total hip replacements.

Authors:  S A Sexton; E Yeung; M P Jackson; S Rajaratnam; J M Martell; W L Walter; B A Zicat; W K Walter
Journal:  J Bone Joint Surg Br       Date:  2011-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.