Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers.

Chih-Hung Tsai1, Jia-Wei Zhang, Yi-Yi Liao, Hao-Li Liu.   

Abstract

Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a surrogate to on/off control the FUS exposure in stage-2 experiments, we demonstrated both excellent sensitivity (92%) and specificity (92.3%) in discriminating BBB-opening occurrence can be obtained in animal treatments, while concurrently achieving a high positive predicted value (95.8%). Wideband ESD was also highly correlated with the occurrence and level of erythrocyte extravasations (r (2)  =  0.81). The proposed system configuration and corresponding analysis based on subharmonic acoustic emissions has the potential to be implemented as a real-time feedback control structure for reliable indication of intact FUS-BBB opening for CNS brain drug delivery.

Entities:  

Mesh:

Year:  2016        PMID: 26988240     DOI: 10.1088/0031-9155/61/7/2926

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

Review 1.  Advances in acoustic monitoring and control of focused ultrasound-mediated increases in blood-brain barrier permeability.

Authors:  Ryan M Jones; Kullervo Hynynen
Journal:  Br J Radiol       Date:  2019-02-28       Impact factor: 3.039

2.  Enhanced Detection of Bubble Emissions Through the Intact Spine for Monitoring Ultrasound-Mediated Blood-Spinal Cord Barrier Opening.

Authors:  Stecia-Marie P Fletcher; Natalia Ogrodnik; Meaghan A O'Reilly
Journal:  IEEE Trans Biomed Eng       Date:  2019-08-22       Impact factor: 4.538

3.  Closed-loop control of targeted ultrasound drug delivery across the blood-brain/tumor barriers in a rat glioma model.

Authors:  Tao Sun; Yongzhi Zhang; Chanikarn Power; Phillip M Alexander; Jonathan T Sutton; Muna Aryal; Natalia Vykhodtseva; Eric L Miller; Nathan J McDannold
Journal:  Proc Natl Acad Sci U S A       Date:  2017-11-13       Impact factor: 11.205

4.  Feedback control of microbubble cavitation for ultrasound-mediated blood-brain barrier disruption in non-human primates under magnetic resonance guidance.

Authors:  Hermes As Kamimura; Julien Flament; Julien Valette; Andrea Cafarelli; Romina Aron Badin; Philippe Hantraye; Benoît Larrat
Journal:  J Cereb Blood Flow Metab       Date:  2018-01-30       Impact factor: 6.200

5.  Ultrasound-induced microbubble cavitation via a transcanal or transcranial approach facilitates inner ear drug delivery.

Authors:  Ai-Ho Liao; Chih-Hung Wang; Ping-Yu Weng; Yi-Chun Lin; Hao Wang; Hang-Kang Chen; Hao-Li Liu; Ho-Chiao Chuang; Cheng-Ping Shih
Journal:  JCI Insight       Date:  2020-02-13

6.  Closed Loop Spatial and Temporal Control of Cavitation Activity with Passive Acoustic Mapping.

Authors:  Arpit Patel; Scott J Schoen; Costas D Arvanitis
Journal:  IEEE Trans Biomed Eng       Date:  2018-11-20       Impact factor: 4.538

Review 7.  Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound.

Authors:  Scott Schoen; M Sait Kilinc; Hohyun Lee; Yutong Guo; F Levent Degertekin; Graeme F Woodworth; Costas Arvanitis
Journal:  Adv Drug Deliv Rev       Date:  2021-11-18       Impact factor: 15.470

8.  Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles.

Authors:  M T Burgess; I Apostolakis; E E Konofagou
Journal:  Phys Med Biol       Date:  2018-03-15       Impact factor: 3.609

9.  Real-Time Passive Acoustic Mapping Using Sparse Matrix Multiplication.

Authors:  Hermes A S Kamimura; Shih-Ying Wu; Julien Grondin; Robin Ji; Christian Aurup; Wenlan Zheng; Marc Heidmann; Antonios N Pouliopoulos; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-12-23       Impact factor: 2.725

10.  Localized blood-brain barrier opening in infiltrating gliomas with MRI-guided acoustic emissions-controlled focused ultrasound.

Authors:  Pavlos Anastasiadis; Dheeraj Gandhi; Yutong Guo; Abdul-Kareem Ahmed; Soren M Bentzen; Costas Arvanitis; Graeme F Woodworth
Journal:  Proc Natl Acad Sci U S A       Date:  2021-09-14       Impact factor: 11.205