BACKGROUND: Although a high incidence of bacteremia after esophageal endoscopic procedures has been reported, the incidence of bacteremia associated with esophageal endoscopic submucosal dissection (ESD) remains unknown. Therefore, we investigated the incidence of bacteremia associated with esophageal ESD. METHODS: From April 2013 to March 2014, patients who underwent esophageal ESD were enrolled prospectively. Two sets of blood cultures were collected from patients at the following time points: (1) immediately after ESD; (2) the next morning; and (3) when fever ≥38 °C was present after ESD. RESULTS: A total of 424 blood culture sets were collected from 101 patients. Six patients had positive blood cultures immediately after ESD (4 %, 7/202 sets). Another patient had a positive blood culture the next morning (0.5 %, 1/202 sets). Ten patients (10 %) developed a post-ESD fever ≥38 °C, and blood cultures from these patients were all negative (0/20 sets). The seven patients with positive blood cultures had no post-ESD fever or infectious symptoms. Growth of Bacteroides thetaiotaomicron was only observed in one patient (1 %) with positive blood cultures immediately after ESD, and this patient was diagnosed with transient bacteremia. The other six patients were considered to have contaminants in their blood cultures. Thus, the incidence of bacteremia after esophageal ESD was 1 % [95 % confidence interval (CI) 0-5 %]. No patient had infectious symptoms, and none required antibiotics after ESD. CONCLUSIONS: The incidence of bacteremia after esophageal ESD was low and post-ESD fever was not associated with bacteremia. We conclude that use of routine prophylactic antibiotics to patients undergoing esophageal ESD is unnecessary. CLINICAL TRIAL REGISTRY NUMBER: UMIN000012908.
BACKGROUND: Although a high incidence of bacteremia after esophageal endoscopic procedures has been reported, the incidence of bacteremia associated with esophageal endoscopic submucosal dissection (ESD) remains unknown. Therefore, we investigated the incidence of bacteremia associated with esophageal ESD. METHODS: From April 2013 to March 2014, patients who underwent esophageal ESD were enrolled prospectively. Two sets of blood cultures were collected from patients at the following time points: (1) immediately after ESD; (2) the next morning; and (3) when fever ≥38 °C was present after ESD. RESULTS: A total of 424 blood culture sets were collected from 101 patients. Six patients had positive blood cultures immediately after ESD (4 %, 7/202 sets). Another patient had a positive blood culture the next morning (0.5 %, 1/202 sets). Ten patients (10 %) developed a post-ESD fever ≥38 °C, and blood cultures from these patients were all negative (0/20 sets). The seven patients with positive blood cultures had no post-ESD fever or infectious symptoms. Growth of Bacteroides thetaiotaomicron was only observed in one patient (1 %) with positive blood cultures immediately after ESD, and this patient was diagnosed with transient bacteremia. The other six patients were considered to have contaminants in their blood cultures. Thus, the incidence of bacteremia after esophageal ESD was 1 % [95 % confidence interval (CI) 0-5 %]. No patient had infectious symptoms, and none required antibiotics after ESD. CONCLUSIONS: The incidence of bacteremia after esophageal ESD was low and post-ESD fever was not associated with bacteremia. We conclude that use of routine prophylactic antibiotics to patients undergoing esophageal ESD is unnecessary. CLINICAL TRIAL REGISTRY NUMBER: UMIN000012908.
Authors: Marc Van Den Eynde; Anne Jouret-Mourin; Christine Sempoux; Hubert Piessevaux; Pierre H Deprez Journal: Gastrointest Endosc Date: 2010-10 Impact factor: 9.427
Authors: Dae Won Ma; Young Hoon Youn; Da Hyun Jung; Jae Jun Park; Jie-Hyun Kim; Hyojin Park Journal: World J Gastroenterol Date: 2018-03-14 Impact factor: 5.742