Literature DB >> 26981457

(1)H-MR imaging of the lungs at 3.0 T.

Sergei I Obruchkov1, Michael D Noseworthy1.   

Abstract

BACKGROUND: One disadvantage of magnetic resonance imaging (MRI) is the inability to adequately image the lungs. Recent advances in hyperpolarized gas technology [e.g., helium-3 ((3)He) and xenon-129 ((129)Xe)] have changed this. However, the required technology is expensive and often needing extra physics or engineering staff. Hence there is considerable interest in developing (1)H (proton)-based MRI approaches that can be readily implemented on standard clinical systems. Thus, the purpose of this work was to compare a newly developed free breathing proton-based MR lung imaging method to that of a standard gadolinium (Gd) based perfusion approach.
METHODS: Healthy volunteers [10] were scanned using a 3-T MRI with 8 parallel receivers, and a cardiac gated fast spin echo (FSE) sequence. Acquisition was cardiac triggered, with different time delays incremented to cover the entire cardiac cycle. Image k-space was filled rectilinearly. But to reduce motion artefacts k-space was retrospectively sorted using the minimal variance algorithm (MVA), based on physiologic data recorded from both the respiratory bellows and electrocardiogram (ECG). Resorted and reconstructed FSE images were compared to contrast enhanced lung images, obtained following intravenous injection of Gd-DTPA-BMA.
RESULTS: Biphasic variation in FSE lung signal intensity was observed across the cardiac cycle with a maximal signal change following rapid cardiac ejection (between S and T waves), and following rapid isovolumetric relaxation. A difference image between systolic and diastolic states in the cardiac cycle resulted in images with improved lung contrast to noise ratio (CNR). FSE image intensity was uniform over lung parenchyma while Gd-based enhancement of spoiled gradient recalled echo (SPGR) images showed gravitational dependence.
CONCLUSIONS: Here we show how 1H-MR images of lung can be obtained during free breathing. The image contrast obtained during this approach is likely the result of flow and oxygen modulation during the cardiac cycle. This free breathing method provides lung images comparable to those obtained using Gd-enhancement. Besides having the advantage of free breathing, this approach doesn't require any Gd-contrast or suffer from methodological problems associated with perfusion (e.g., poor bolus timing). However, as gravitational differences typically observed in lung perfusion are not visible with this method it is not providing exclusive microvascular perfusion information.

Entities:  

Keywords:  Lung; free breathing; magnetic resonance imaging (MRI); perfusion

Year:  2016        PMID: 26981457      PMCID: PMC4775243          DOI: 10.3978/j.issn.2223-4292.2016.02.09

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  25 in total

1.  Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

Authors:  M Miyazaki; S Sugiura; F Tateishi; H Wada; Y Kassai; H Abe
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

2.  Magnetic resonance imaging of pulmonary parenchymal disease using a modified breath-hold 3D gradient-echo technique: initial observations.

Authors:  Till R Bader; Richard C Semelka; Monica S Pedro; Diane M Armao; Mark A Brown; Paul L Molina
Journal:  J Magn Reson Imaging       Date:  2002-01       Impact factor: 4.813

3.  Temporal dynamics of blood flow effects in half-Fourier fast spin echo (1)H magnetic resonance imaging of the human lungs.

Authors:  J Knight-Scott; S D Keilholz-George; V M Mai; J M Christopher
Journal:  J Magn Reson Imaging       Date:  2001-10       Impact factor: 4.813

4.  Ventilation-perfusion ratio of signal intensity in human lung using oxygen-enhanced and arterial spin labeling techniques.

Authors:  Vu M Mai; Benjamin Liu; Jason A Polzin; Wei Li; Saban Kurucay; Alexander A Bankier; Jack Knight-Scott; Priti Madhav; Robert R Edelman; Qun Chen
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

5.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

6.  Prospective comparison of MR lung perfusion and lung scintigraphy.

Authors:  Y Berthezène; P Croisille; M Wiart; N Howarth; C Houzard; O Faure; P Douek; M Amiel; D Revel
Journal:  J Magn Reson Imaging       Date:  1999-01       Impact factor: 4.813

7.  Multiparametric oxygen-enhanced functional lung imaging in 3D.

Authors:  Kathrin R F Hemberger; Peter M Jakob; Felix A Breuer
Journal:  MAGMA       Date:  2014-10-09       Impact factor: 2.310

8.  [MR imaging of lung ventilation with aerosolized gadolinium-chelates].

Authors:  P Haage; S Karaagac; E Spüntrup; G Adam; R W Günther
Journal:  Rofo       Date:  2003-02

9.  Assessment of lung perfusion impairment in patients with pulmonary artery-occlusive and chronic obstructive pulmonary diseases with noncontrast electrocardiogram-gated fast-spin-echo perfusion MR imaging.

Authors:  Nobuhiko Ogasawara; Kazuyoshi Suga; Mohammed Zaki; Munemasa Okada; Yasuhiko Kawakami; Naofumi Matsunaga
Journal:  J Magn Reson Imaging       Date:  2004-10       Impact factor: 4.813

Review 10.  Functional lung imaging using hyperpolarized gas MRI.

Authors:  Sean B Fain; Frank R Korosec; James H Holmes; Rafael O'Halloran; Ronald L Sorkness; Thomas M Grist
Journal:  J Magn Reson Imaging       Date:  2007-05       Impact factor: 4.813

View more
  1 in total

1.  Assessment of MR imaging during one-lung flooding in a large animal model.

Authors:  Frank Wolfram; Daniel Güllmar; Joachim Böttcher; Harald Schubert; Sabine Bischoff; Jürgen R Reichenbach; Thomas Günther Lesser
Journal:  MAGMA       Date:  2019-06-01       Impact factor: 2.310

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.